Xiaoliang Zhang

Prof. Xiaoliang Zhang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2011 in Medical Physics
Verified
Journal Article
Closed access
PDF file
YLYe Li
Ye Li
ZXZhentian Xie
Zhentian Xie
YPYong Pang
Yong Pang
DVDaniel Vigneron
Daniel Vigneron
XZXiaoliang Zhang
Xiaoliang Zhang

1 June 2016 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
OROmar Rutledge
Omar Rutledge
TKTiffany Kwak
Tiffany Kwak
PCPeng Cao
Peng Cao
XZXiaoliang Zhang
Xiaoliang Zhang

3 November 2011 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
CWChunsheng Wang
Chunsheng Wang
YLYe Li
Ye Li
BWBing Wu
Bing Wu
DXDuan Xu
Duan Xu
SNSarah J. Nelson
Sarah J. Nelson
XZXiaoliang Zhang
Xiaoliang Zhang

19 August 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
YPYong Pang
Yong Pang
DVDaniel B. Vigneron
Daniel B. Vigneron
XZXiaoliang Zhang
Xiaoliang Zhang

4 March 2015 in Applied Magnetic Resonance
Verified
Journal Article
Closed access
PDF file
XYXinqiang Yan
Xinqiang Yan
LWLong Wei
Long Wei
RXRong Xue
Rong Xue
XZXiaoliang Zhang
Xiaoliang Zhang

8 February 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YPYong Pang
Yong Pang
XZXiaoliang Zhang
Xiaoliang Zhang
Sparse MRI has been introduced to reduce the acquisition time and raw data size by undersampling the k-space data. However, the image quality, particularly the contrast to noise ratio (CNR), decreases with the undersampling rate. In this work, we proposed an interpolated Compressed Sensing (iCS) method to further enhance the imaging speed or reduce data size without significant sacrifice of image quality and CNR for multi-slice two-dimensional sparse MR imaging in humans. This method utilizes the k-space data of the neighboring slice in the multi-slice acquisition. The missing k-space data of a highly undersampled slice are estimated by using the raw data of its neighboring slice multiplied by a weighting function generated from low resolution full k-space reference images. In-vivo MR imaging in human feet has been used to investigate the feasibility and the performance of the proposed iCS method. The results show that by using the proposed iCS reconstruction method, the average image error can be reduced and the average CNR can be improved, compared with the conventional sparse MRI reconstruction at the same undersampling rate.