Maria J Suarez

Prof. Maria J Suarez

Department Restorative Dentistry and Buccofacial Prosthesis, Faculty Odontology, University Complutense of Madrid, 28040 Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Pedro DiazPedro Diaz
Pedro Diaz
EGEsther Gonzalo
Esther Gonzalo
LVLuis J. Gil Villagra
Luis J. Gil Villagra
BMBarbara Miegimolle
Barbara Miegimolle
Maria J SuarezMaria J Suarez
Maria J Suarez
Background: Peri-implantitis is a usual finding but estimates of its prevalence fluctuate very much. This may be due to the wide variety of disease definitions. This systematic review aims to estimate the overall prevalence of peri-implantitis and the effect of different study designs, function times and use of probing depth on prevalence rate.Methods: Following electronic and manual searches of the literature published from January 2005 to December 2021, data were extracted from the studies fitting the study criteria. Fifty-seven articles were included in this study.Results: Prevalence of peri-implantitis was 19.53% (95% CI 12.87–26.19) at the patient-level, and 12.53% (95% CI 11.67–13.39) at the implant-level and it remains highly variable even following restriction to the clinical case definition. The use of probing depth like diagnostic criteria affected the prevalence data.Conclusion: The results indicate that it remains essential the identification of the diagnostic markers for more accurate disease classification.

1 December 2009 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
EGEsther Gonzalo
Esther Gonzalo
Maria J SuarezMaria J Suarez
Maria J Suarez
BSBenjamin Serrano
Benjamin Serrano
JLJose F.L. Lozano
Jose F.L. Lozano

22 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
Rubén Comino GarayoaRubén Comino Garayoa
Rubén Comino Garayoa
JPJesus Pelaez
Jesus Pelaez
CTCelia Tobar
Celia Tobar
VAVerónica Rodríguez Alonso
Verónica Rodríguez Alonso
Maria J SuarezMaria J Suarez
Maria J Suarez
This systematic review aims to evaluate the different pretreatments of the zirconia surface and resin cement in order to determine a valid operative protocol for adhesive cementation. Methodologies conducted for this study followed the Prisma (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. An electronic search was performed in four databases. The established focus question was: “What type of surface conditioning method is the one that obtains the best adhesion values to zirconia over time by applying a resin cement?” Forty-five relevant papers were found to qualify for final inclusion. In total, 260 different surface pretreatment methods, mainly combinations of air-abrasion protocols and adhesive promoters, were investigated. Altogether, the use of two artificial aging methods, three types of cement and four testing methods was reported. The results showed that mechanicochemical surface pretreatments offered the best adhesive results. Self-adhesive cement and those containing 10-MDP obtained the best results in adhesion to zirconia. Artificial aging reduced adhesion, so storage in water for 30 days or thermocycling for 5000 cycles is recommended. A standardized adhesive protocol has not been established due to a lack of evidence

1 February 2011 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
FMFrancisco Martínez-Rus
Francisco Martínez-Rus
Maria J SuarezMaria J Suarez
Maria J Suarez
BRBegoña Rivera
Begoña Rivera
GRGuillermo Pradíes Ramiro
Guillermo Pradíes Ramiro

MAMaría Isabel Isabel Albanchez-González
María Isabel Isabel Albanchez-González
JBJorge Cortés-Bretón Brinkmann
Jorge Cortés-Bretón Brinkmann
JPJesus Pelaez
Jesus Pelaez
CLCarlos López-Suárez
Carlos López-Suárez
VAVerónica Rodríguez Alonso
Verónica Rodríguez Alonso
Maria J SuarezMaria J Suarez
Maria J Suarez
The aim of this systematic review was to evaluate the in vitro accuracy of dental implants impressions taken with intraoral scanner compared with impressions taken with conventional techniques. Two independent reviewers conducted a systematic electronic search in the PubMed, Web of Science and Scopus databases. Some of the employed key terms, combined with the help of Boolean operators, were: “dental implants”, “impression accuracy”, “digital impression” and “conventional impression”. Publication dates ranged from the earliest article available until 31 July 2021. A total of 26 articles fulfilled the inclusion criteria: 14 studies simulated complete edentation (CE), nine partial edentation (PE) and only two simulated a single implant (SI); One study simulated both CE and SI. In cases of PE and SI, most of the studies analyzed found greater accuracy with conventional impression (CI), although digital impression (DI) was also considered adequate. For CE the findings were inconclusive as six studies found greater accuracy with DI, five found better accuracy with CI and four found no differences. According to the results of this systematic review, DI is a valid alternative to CI for implants in PE and SI, although CI appear to be more accurate. For CE the findings were inconclusive, so more studies are needed before DI can be recommended for all implant-supported restorations.

18 November 2020 in Biology
Verified
Journal Article
Open access
PDF file
Rubén Comino GarayoaRubén Comino Garayoa
Rubén Comino Garayoa
JBJorge Cortés-Bretón Brinkmann
Jorge Cortés-Bretón Brinkmann
JPJesus Pelaez
Jesus Pelaez
CLCarlos López-Suárez
Carlos López-Suárez
JGJosé María Martínez González
José María Martínez González
Maria J SuarezMaria J Suarez
Maria J Suarez
The purpose of this scoping review was to describe the current state of knowledge and understanding of allergies to titanium dental implants. A scoping review was conducted following the Prisma Extension for Scoping Reviews checklist. An electronic search was performed in five databases complemented by manual and grey literature searches. Fifty-two relevant papers were included for final review. Titanium particles can be released from the surfaces of dental implants in a process called tribocorrosion, which may contribute to bone loss due to inflammatory reaction. Diverse mechanisms have been described that may trigger allergy to titanium, as well as the clinical signs that manifest as the allergy develops. Allergies to titanium are uncommon but represent a real possibility that should not be overlooked in patients requiring prosthodontic rehabilitation with dental implants. Allergy can trigger a range of symptoms. Patients who have already been diagnosed with allergies to other metals will be more predisposed to suffering an allergy to titanium. Further investigation is needed in order to measure the true scope of these allergies.