Sergey S. Shevkoplyas

Prof. Dr. Sergey S. Shevkoplyas

Professor of Biomedical Engineering, University of Houston, Houston, TX 77204-5060, USA
+1

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2007 in Science
Verified
Journal Article
Closed access
PDF file
AFAdam W. Feinberg
Adam W. Feinberg
AFAlex Feigel
Alex Feigel
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
SSSean Sheehy
Sean Sheehy
GWGeorge M. Whitesides
George M. Whitesides
KPKevin Kit Parker
Kevin Kit Parker
We demonstrate the assembly of biohybrid materials from engineered tissues and synthetic polymer thin films. The constructs were built by culturing neonatal rat ventricular cardiomyocytes on polydimethylsiloxane thin films micropatterned with extracellular matrix proteins to promote spatially ordered, two-dimensional myogenesis. The constructs, termed muscular thin films, adopted functional, three-dimensional conformations when released from a thermally sensitive polymer substrate and were designed to perform biomimetic tasks by varying tissue architecture, thin-film shape, and electrical-pacing protocol. These centimeter-scale constructs perform functions as diverse as gripping, pumping, walking, and swimming with fine spatial and temporal control and generating specific forces as high as 4 millinewtons per square millimeter.

22 August 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MFMichael J. Fuerstman
Michael J. Fuerstman
ALAnn Lai
Ann Lai
MTMeghan E. Thurlow
Meghan E. Thurlow
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
HSHoward A. Stone
Howard A. Stone
GWGeorge M. Whitesides
George M. Whitesides
This paper derives the difference in pressure between the beginning and the end of a rectangular microchannel through which a flowing liquid (water, with or without surfactant, and mixtures of water and glycerol) carries bubbles that contact all four walls of the channel. It uses an indirect method to derive the pressure in the channel. The pressure drop depends predominantly on the number of bubbles in the channel at both low and high concentrations of surfactant. At intermediate concentrations of surfactant, if the channel contains bubbles (of the same or different lengths), the total, aggregated length of the bubbles in the channel is the dominant contributor to the pressure drop. The difference between these two cases stems from increased flow of liquid through the “gutters”—the regions of the system bounded by the curved body of the bubble and the corners of the channel—in the presence of intermediate concentrations of surfactant. This paper presents a systematic and quantitative investigation of the influence of surfactants on the flow of fluids in microchannels containing bubbles. It derives the contributions to the overall pressure drop from three regions of the channel: (i) the slugs of liquid between the bubbles (and separated from the bubbles), in which liquid flows as though no bubbles were present; (ii) the gutters along the corners of the microchannels; and (iii) the curved caps at the ends of the bubble.

17 November 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XYXiaoxi Yang
Xiaoxi Yang
OFOmid Forouzan
Omid Forouzan
TBTheodore P. Brown
Theodore P. Brown
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
Many diagnostic tests in a conventional clinical laboratory are performed on blood plasma because changes in its composition often reflect the current status of pathological processes throughout the body. Recently, a significant research effort has been invested into the development of microfluidic paper-based analytical devices (μPADs) implementing these conventional laboratory tests for point-of-care diagnostics in resource-limited settings. This paper describes the use of red blood cell (RBC) agglutination for separating plasma from finger-prick volumes of whole blood directly in paper, and demonstrates the utility of this approach by integrating plasma separation and a colorimetric assay in a single μPAD. The μPAD was fabricated by printing its pattern onto chromatography paper with a solid ink (wax) printer and melting the ink to create hydrophobic barriers spanning through the entire thickness of the paper substrate. The μPAD was functionalized by spotting agglutinating antibodies onto the plasma separation zone in the center and the reagents of the colorimetric assay onto the test readout zones on the periphery of the device. To operate the μPAD, a drop of whole blood was placed directly onto the plasma separation zone of the device. RBCs in the whole blood sample agglutinated and remained in the central zone, while separated plasma wicked through the paper substrate into the test readout zones where analyte in plasma reacted with the reagents of the colorimetric assay to produce a visible color change. The color change was digitized with a portable scanner and converted to concentration values using a calibration curve. The purity and yield of separated plasma was sufficient for successful operation of the μPAD. This approach to plasma separation based on RBC agglutination will be particularly useful for designing fully integrated μPADs operating directly on small samples of whole blood.

25 July 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
ASAdam C. Siegel
Adam C. Siegel
RWRobert M. Westervelt
Robert M. Westervelt
MPMara G. Prentiss
Mara G. Prentiss
GWGeorge M. Whitesides
George M. Whitesides
This paper describes a model of the motion of superparamagnetic beads in a microfluidic channel under the influence of a weak magnetic field produced by an electric current passing through a coplanar metal wire. The model based on the conventional expression for the magnetic force experienced by a superparamagnetic bead (suspended in a biologically relevant medium) and the parameters provided by the manufacturer failed to match the experimental data. To fit the data to the model, it was necessary to modify the conventional expression for the force to account for the non-zero initial magnetization of the beads, and to use the initial magnetization and the magnetic susceptibility of the beads as adjustable parameters. The best-fit value of susceptibility deviated significantly from the value provided by the manufacturer, but was in good agreement with the value computed using the magnetization curves measured independently for the beads from the same vial as those used in the experiment. The results of this study will be useful to researchers who need an accurate prediction of the behavior of superparamagnetic beads in aqueous suspensions under the influence of weak magnetic fields. The derivation of the force on a magnetic bead due to a magnetic field also identifies the correct treatment to use for this interaction, and resolves discrepancies present throughout the literature.

18 December 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SHS. Elizabeth Hulme
S. Elizabeth Hulme
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
AMAlison P. McGuigan
Alison P. McGuigan
JAJavier Apfeld
Javier Apfeld
WFWalter Fontana
Walter Fontana
GWGeorge M. Whitesides
George M. Whitesides
This article describes the fabrication of a microfluidic device for the liquid culture of many individual nematode worms (Caenorhabditis elegans) in separate chambers. Each chamber houses a single worm from the fourth larval stage until death, and enables examination of a population of individual worms for their entire adult lifespans. Adjacent to the chambers, the device includes microfluidic worm clamps, which enable periodic, temporary immobilization of each worm. The device made it possible to track changes in body size and locomotion in individual worms throughout their lifespans. This ability to perform longitudinal measurements within the device enabled the identification of age-related phenotypic changes that correlate with lifespan in C. elegans.

16 August 2007 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SHS. Elizabeth Hulme
S. Elizabeth Hulme
Sergey S. ShevkoplyasSergey S. Shevkoplyas
Sergey S. Shevkoplyas
JAJavier Apfeld
Javier Apfeld
WFWalter Fontana
Walter Fontana
GWGeorge M. Whitesides
George M. Whitesides
This paper describes the fabrication of a microfluidic device for rapid immobilization of large numbers of live C. elegans for performing morphological analysis, microsurgery, and fluorescence imaging in a high-throughput manner. The device consists of two principal elements: (i) an array of 128 wedge-shaped microchannels, or clamps, which physically immobilize worms, and (ii) a branching network of distribution channels, which deliver worms to the array. The flow of liquid through the device (driven by a constant pressure difference between the inlet and the outlet) automatically distributes individual worms into each clamp. It was possible to immobilize more than 100 worms in less than 15 min. The immobilization process was not damaging to the worms: following removal from the array of clamps, worms lived typical lifespans and reproduced normally. The ability to monitor large numbers of immobilized worms easily and in parallel will enable researchers to investigate physiology and behavior in large populations of C. elegans.