Muhammad Saqib

Dr. Muhammad Saqib

Fraunhofer Institute for Ceramic Technologies and Systems, Dresden, Saxony, Germany
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Natalia BeshchasnaNatalia Beshchasna
Natalia Beshchasna
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
HKHonorata Kraskiewicz
Honorata Kraskiewicz
ŁWŁukasz Wasyluk
Łukasz Wasyluk
OKOleg Kuzmin
Oleg Kuzmin
EAEcaterina Andronescu
Ecaterina Andronescu
Cardiovascular diseases are the most distributed cause of death worldwide. Stenting of arteries as a percutaneous transluminal angioplasty procedure became a promising minimally invasive therapy based on re-opening narrowed arteries by stent insertion. In order to improve and optimize this method, many research groups are focusing on designing new or improving existent stents. Since the beginning of the stent development in 1986, starting with bare-metal stents (BMS), these devices have been continuously enhanced by applying new materials, developing stent coatings based on inorganic and organic compounds including drugs, nanoparticles or biological components such as genes and cells, as well as adapting stent designs with different fabrication technologies. Drug eluting stents (DES) have been developed to overcome the main shortcomings of BMS or coated stents. Coatings are mainly applied to control biocompatibility, degradation rate, protein adsorption, and allow adequate endothelialization in order to ensure better clinical outcome of BMS, reducing restenosis and thrombosis. As coating materials (i) organic polymers: polyurethanes, poly(ε-caprolactone), styrene-b-isobutylene-b-styrene, polyhydroxybutyrates, poly(lactide-co-glycolide), and phosphoryl choline; (ii) biological components: vascular endothelial growth factor (VEGF) and anti-CD34 antibody and (iii) inorganic coatings: noble metals, wide class of oxides, nitrides, silicide and carbide, hydroxyapatite, diamond-like carbon, and others are used. DES were developed to reduce the tissue hyperplasia and in-stent restenosis utilizing antiproliferative substances like paclitaxel, limus (siro-, zotaro-, evero-, bio-, amphi-, tacro-limus), ABT-578, tyrphostin AGL-2043, genes, etc. The innovative solutions aim at overcoming the main limitations of the stent technology, such as in-stent restenosis and stent thrombosis, while maintaining the prime requirements on biocompatibility, biodegradability, and mechanical behavior. This paper provides an overview of the existing stent types, their functionality, materials, and manufacturing conditions demonstrating the still huge potential for the development of promising stent solutions.

1 June 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
NBNatalia Beshchasna
Natalia Beshchasna
AHAu Yeung Kwan Ho
Au Yeung Kwan Ho
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
HKHonorata Kraśkiewicz
Honorata Kraśkiewicz
ŁWŁukasz Wasyluk
Łukasz Wasyluk
EAEcaterina Andronescu
Ecaterina Andronescu

30 November 2021 in IEEE Access
Verified
Journal Article
Open access
KRKhalid Rasheed
Khalid Rasheed
FJFaraz Junejo
Faraz Junejo
AMAyesha Malik
Ayesha Malik
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
During pregnancy, fetal ultrasound provides essential insight into a baby’s growth and development. In this ultrasound, accurate assessment of fetal head biometry is critical to the clinical management of pregnancy. Current methodologies used for fetal head biometry heavily rely upon sonographer skills and experience to locate a baby’s head. In this paper a novel approach is proposed to automate the fetal head biometry using live ultrasound feed; which is also capable of tackling low abdominal contrast against surroundings. Proposed model is trained on ALEXNET and UNET for classification and segmentation of headframes respectively from ultrasound video. To compute biparietal diameter (BPD) and head circumference (HC); which are essential requirements to compute gestational age, an ellipse is drawn on the contour of the annotated segmented fetal head. It should be noted that to validate gestational age estimate, ellipse are drawn on multiple best classified headframes obtained using ALEXNET. The proposed system is able to estimate gestational age within clinically acceptable ± one week of observed gestational age with an accuracy of 96%. Moreover, it uses robust machine vision features to reduce the sonographer’s interaction with the system, thus reducing the overall procedure time and making it independent of sonographer’s skill.

3 February 2021 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
SGSemen Goreninskii
Semen Goreninskii
NDNadezhda Danilenko
Nadezhda Danilenko
Evgeniy BobasovEvgeniy Bobasov
Evgeniy Bobasov
AEAnastasia Evtina
Anastasia Evtina
MBMikhail Buldakov
Mikhail Buldakov
Sergei TverdokhlebovSergei Tverdokhlebov
Sergei Tverdokhlebov

21 September 2022 in Surfaces and Interfaces
Verified
Journal Article
Closed access
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
NBNatalia Beshchasna
Natalia Beshchasna
RPRiccardo Pelaccia
Riccardo Pelaccia
ARAnton Roshchupkin
Anton Roshchupkin
IYIlya Yanko
Ilya Yanko
LOLeonardo Orazi
Leonardo Orazi

12 April 2021 in IEEE Access
Verified
Journal Article
Open access
Muhammad SaqibMuhammad Saqib
Muhammad Saqib
OKOleg S. Kuzmin
Oleg S. Kuzmin
HKHonorata Kraskiewicz
Honorata Kraskiewicz
LWLukasz Wasyluk
Lukasz Wasyluk
Gianaurelio CunibertiGianaurelio Cuniberti
Gianaurelio Cuniberti
NBNatalia Beshchasna
Natalia Beshchasna
Coronary artery disease (CAD) affects every fifth person in the world. The gold-standard treatment for CAD is stent implantation, however, the existing therapy is not sufficient. In recent years, titanium oxynitride (TiO x N y ) coatings on bare metal stents (BMSs) attracted the attention of many researchers around the world due to their promising results and improved surface properties. However, good coating adhesion and coverage of the inner surface in stent applications is still a challenging task. Moreover, enhanced corrosion resistance and durability over a longer period under the influence of an aggressive biological environment is one of the main requirements while developing novel coatings for bare-metal stents. In this work, the titanium oxynitride (TiO x N y ) coated stainless steel stents were fabricated by magnetron sputtering and the corrosion behavior of coated and uncoated stents has been studied using immersion, fluid dynamic, and electrochemical corrosion tests. For the first time, the entire stent surface has been used for quantitative corrosion tests on stents. We discuss and compare the in vitro biostability and corrosion behavior of bare stainless steel (316L) and titanium oxynitride films (TiO x N y ) coated stents.TiO x N y coatings provide valuable stability to the BMS against harsh environments or conditions. The coated stents are remarkably more stable when compared with the reference uncoated stents (316L BMS), regardless of the ratio of O 2 and N 2 . The variation of stent coating parameters is still possible to get more anticorrosive and biostable behavior; therefore, the results could provide the basis for further research.