Emma Howson

Dr. Emma Howson


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of Virological Methods
Verified
Journal Article
Open access
EHEmma Howson
Emma Howson
YKYohei Kurosaki
Yohei Kurosaki
JYJiro Yasuda
Jiro Yasuda
MTMasayoshi Takahashi
Masayoshi Takahashi
HGHiroaki Goto
Hiroaki Goto
VFVeronica Fowler
Veronica Fowler
This study describes the first multiway comparison of portable isothermal assays for the detection of foot-and-mouth disease virus (FMDV), benchmarked against real-time reverse transcription RT-PCR (rRT-PCR). The selected isothermal chemistries included reverse transcription loop-mediated isothermal amplification (RT-LAMP) and reverse transcription recombinase polymerase amplification (RT-RPA). The analytical sensitivity of RT-LAMP was comparable to rRT-PCR (101 RNA copies), while RT-RPA was one log10 less sensitive (102 RNA copies). Diagnostic performance was evaluated using a panel of 35 samples from FMDV-positive cattle and eight samples from cattle infected with other vesicular viruses. Assay concordance for RT-LAMP and RT-RPA was 86-98% and 67-77%, respectively, when compared to rRT-PCR, with discordant samples consistently having high rRT-PCR cycle threshold values (no false-positives were detected for any assay). In addition, a hierarchy of sample preparation methods, from robotic extraction to simple dilution of samples, for epithelial suspensions, serum and oesophageal-pharyngeal (OP) fluid were evaluated. Results obtained for RT-LAMP confirmed that FMDV RNA can be detected in the absence of RNA extraction. However, simple sample preparation methods were less encouraging for RT-RPA, with accurate results only obtained when using RNA extraction. Although the evaluation of assay performance is specific to the conditions tested in this study, the compatibility of RT-LAMP chemistry with multiple sample types, both in the presence and absence of nucleic acid extraction, provides advantages over alternative isothermal chemistries and alternative pen-side diagnostics such as antigen-detection lateral-flow devices. These characteristics of RT-LAMP enable the assay to be performed over a large diagnostic detection window, providing a realistic means to rapidly confirm positive FMD cases close to the point of sampling.

20 April 2020 in Pathogens
Verified
Journal Article
Open access
PDF file
EHEmma Howson
Emma Howson
Richard OrtonRichard Orton
Richard Orton
VMValerie Mioulet
Valerie Mioulet
TLTiziana Lembo
Tiziana Lembo
DKDonald P. King
Donald P. King
VFVeronica Fowler
Veronica Fowler
Real-time PCR (rPCR) is a widely accepted diagnostic tool for the detection and quantification of nucleic acid targets. In order for these assays to achieve high sensitivity and specificity, primer and probe-template complementarity is essential; however, mismatches are often unavoidable and can result in false-negative results and errors in quantifying target sequences. Primer and probe sequences therefore require continual evaluation to ensure they remain fit for purpose. This paper describes the development of a linear model and associated computational tool (GoPrime) designed to predict the performance of rPCR primers and probes across multiple sequence data. Empirical data were generated using DNA oligonucleotides (n = 90) that systematically introduced variation in the primer and probe target regions of a diagnostic assay routinely used to detect foot-and-mouth disease virus (FMDV); an animal virus that exhibits a high degree of sequence variability. These assays revealed consistent impacts of patterns of substitutions in primer and probe-sites on rPCR cycle threshold (CT) and limit of detection (LOD). These data were used to populate GoPrime, which was subsequently used to predict rPCR results for DNA templates (n = 7) representing the natural sequence variability within FMDV. GoPrime was also applicable to other areas of the FMDV genome, with predictions for the likely targets of a FMDV-typing assay consistent with published experimental data. Although further work is required to improve these tools, including assessing the impact of primer-template mismatches in the reverse transcription step and the broader impact of mismatches for other assays, these data support the use of mathematical models for rapidly predicting the performance of rPCR primers and probes in silico.

16 December 2020 in medRxiv
Verified
Preprint
Open access
PDF file
APAnetta Ptasinska
Anetta Ptasinska
CWCelina Whalley
Celina Whalley
ABAndrew Bosworth
Andrew Bosworth
CPCharlie Poxon
Charlie Poxon
CBClare Bryer
Clare Bryer
ABAndrew D Beggs
Andrew D Beggs
Introduction: Rapid, high throughput diagnostics are a valuable tool, allowing the detection of SARS-CoV-2 in populations, in order to identify and isolate people with asymptomatic and symptomatic infections. Reagent shortages and restricted access to high throughput testing solutions have limited the effectiveness of conventional assays such as reverse transcriptase quantitative PCR (RTqPCR), particularly throughout the first months of the pandemic. We investigated the use of LamPORE, where loop mediated isothermal amplification (LAMP) is coupled to nanopore sequencing technology, for the detection of SARS CoV 2 in symptomatic and asymptomatic populations. Methods: In an asymptomatic prospective cohort; health care workers across four sites (Birmingham, Southampton, Basingstoke and Manchester) self swabbed with nasopharyngeal swabs weekly for three weeks and supplied a saliva specimen daily. These samples were tested for SARS CoV 2 RNA using the Oxford Nanopore LamPORE system and a reference RTqPCR assay on extracted sample RNA. A second retrospective cohort of 848 patients with influenza like illness from March 2020 to June 2020, were similarly tested from nasopharyngeal swabs. Results: In the asymptomatic cohort a total of 1200 participants supplied 23,427 samples (3,966 swab, 19,461 saliva) over a three-week period. The incidence of SARS CoV 2 was 0.95% using LamPORE. Diagnostic sensitivity and specificity was > 99.5% in both swab and saliva asymptomatic samples as compared to the reference RTqPCR test. In the retrospective symptomatic cohort, the incidence was 13.4% and the sensitivity and specificity were 100%. Conclusions: LamPORE is a highly accurate methodology for the detection of SARS CoV 2 in both the symptomatic and asymptomatic population settings and can be used as an alternative to RTqPCR.

21 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
EHEmma Howson
Emma Howson
SKStephen Kidd
Stephen Kidd
JSJason Sawyer
Jason Sawyer
CCClaire Cassar
Claire Cassar
DCDavid Cross
David Cross
VFVeronica Fowler
Veronica Fowler
We describe the optimization of a simplified sample preparation method which permits rapid and direct detection of SARS-CoV-2 RNA within saliva using reverse-transcription loop-mediated isothermal amplification (RT-LAMP). Treatment of saliva samples prior to RT-LAMP by dilution 1:1 in Mucolyse™, followed by dilution (within the range of 1:5 to 1:40) in 10% (w/v) Chelex © 100 Resin and a 98°C heat step for 2 minutes enabled detection of SARS-CoV-2 RNA in all positive saliva samples tested, with no amplification detected in pooled negative saliva. The time to positivity for which SARS- CoV-2 RNA was detected in these positive saliva samples was proportional to the real-time reverse- transcriptase PCR cycle threshold (C T ), with SARS-CoV-2 RNA detected in as little as 05:43 (C T 21.08), 07:59 (C T 24.47) and 08:35 (C T 25.27) minutes, respectively. The highest C T where direct RT-LAMP detected SARS-CoV-2 RNA was 31.39 corresponding to a 1:40 dilution of a positive saliva sample with a starting C T of 25.27. When RT-LAMP was performed on pools of SARS-CoV-2 negative saliva samples spiked with whole inactivated SARS-CoV-2 virus, RNA was detected at dilutions spanning 1:5 to 1:160 representing C T ’s spanning 22.49-26.43. Here we describe a simple but critical rapid sample preparation method which can be used up front of RT-LAMP to permit direct detection of SARS-CoV- 2 within saliva samples. Saliva is a sample which can be collected non-invasively without the use of highly skilled staff and critically can be obtained from both health care and home settings. Critically, this approach overcomes both the requirement and validation of different swabs and the global bottleneck observed in obtaining RNA extraction robots and reagents to enable molecular testing by PCR. Such testing opens the possibility of public health approaches for effective intervention to control the COVID-19 pandemic through regular SARS-CoV-2 testing at a population scale, combined with isolation and contact tracing for positive cases.