Chenyu Jiang

Chenyu Jiang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2021 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
JYJuan Yue
Juan Yue
Li LiLi Li
Li Li
CJChenyu Jiang
Chenyu Jiang
QMQian Mei
Qian Mei
WDWen-Fei Dong
Wen-Fei Dong
RYRuhong Yan
Ruhong Yan
Photodynamic therapy, as an effective treatment for superficial tumors, has attracted more and more attention. The development of safe, biocompatible and in vivo photosensitive materials is helpful to promote photodynamic therapy. Here we report green fluorescent carbon quantum dots prepared from a natural vitamin, riboflavin (VB2), as a photosensitizer. The VB2-based carbon dots have excellent water solubility and biocompatibility, and their singlet oxygen generation ability is much stronger than that of riboflavin itself. Through endocytosis, the carbon dots can easily enter the cells and show bright green fluorescence. In vivo experiments show that after photodynamic therapy the carbon dots can significantly inhibit the growth of tumors, and will not have toxic and side effects on other organs.

8 July 2020 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
XKXinyue Kou
Xinyue Kou
XZXujia Zhang
Xujia Zhang
XSXuejun Shao
Xuejun Shao
CJChenyu Jiang
Chenyu Jiang
LNLimin Ning
Limin Ning

17 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
DYDian Yang
Dian Yang
Li LiLi Li
Li Li
LCLei Cao
Lei Cao
ZCZhimin Chang
Zhimin Chang
QMQian Mei
Qian Mei
WDWen-Fei Dong
Wen-Fei Dong
Reactive oxygen species (ROS) in the body play an important role in various processes. It is well known that harmful high levels of ROS can cause many problems in living organisms in a variety of ways. One effective way to remove intracellular ROS is to use reducing materials that can enter the cell. Herein, we developed a strong reducing carbon nano-dot from a natural product, lutein, as an initial raw material. This is a hydrothermal synthesis method with the advantages of simplicity, high yield, mild reaction conditions, and environmental friendliness. The prepared carbon dots exhibit bright blue fluorescence, and have good water solubility and biocompatibility. In particular, the carbon dots can easily enter the cell and effectively remove ROS. Therefore, the carbon dots are thought to protect cells from oxidative damage by high levels of ROS.

17 September 2022 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
HHHuijie Hu
Huijie Hu
JWJingkai Wang
Jingkai Wang
XYXiaofei Yi
Xiaofei Yi
KLKaicheng Lin
Kaicheng Lin
SMSiyu Meng
Siyu Meng
YSYizhi Song
Yizhi Song
Gram staining (GS) is one of the routine microbiological operations to classify bacteria based on the cell wall structure. Accurate GS classification of pathogens is of great significance since it helps correct administration of antimicrobial treatment. The laborious procedure and low sensitivity results related to conventional GS have resulted in reluctance among clinicians. In this study, we integrate confocal Raman spectroscopy and machine learning techniques to distinguish Gram-negative (GN) or Gram-positive (GP) bacteria. A single-cell Raman database including seven most common clinical pathogens (three GP strains and four GN strains) was constructed. Machine learning algorithms including the support-vector machine (SVM), k-nearest neighbors' algorithm (k-NN), gradient boosting machine (GBM), linear discriminant analysis (LDA), and t-distributed stochastic neighbor embedding (t-SNE) were trained to achieve the binary classification for GS. With such a relatively small database, the SVM model achieved the highest accuracy of 98.1%. The molecular signatures of GN and GP embedded in their Raman fingerprints were identified with hierarchical cluster analysis (HCA). The results indicated that Raman peaks for peptidoglycan and teichoic acid were the most significant factors that contributed to accurate classification. The Raman machine learning approach could greatly enhance the diagnosis of pathogenic infections.

13 December 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
SJSun Jing
Sun Jing
DSDongxin Shi
Dongxin Shi
SJSun Jing
Sun Jing
XYXiaolin Yu
Xiaolin Yu
BSBinghong Song
Binghong Song
CJChenyu Jiang
Chenyu Jiang
The monitoring of acetone in exhaled breath is expected to provide a noninvasive and painless method for dynamic monitoring of summarized physiological metabolic status during obesity treatment. Although the commonly used Mass Spectrometry (MS) technology has high accuracy, the long detection time and large equipment size limit the application of daily bedside detection. As for the real-time and accurate detection of acetone, the gas sensor has become the best choice of gas detection technology, but it is easy to be disturbed by water vapor in breath gas. An integrated breath gas detection system based on cavity ring-down spectroscopy (CRDS) is reported in this paper, which is a laser absorption spectroscopy technique with high-sensitivity detection and absolute quantitative analysis. The system uses a 266 nm single-wavelength ultraviolet laser combined with a breath gas pretreatment unit to effectively remove the influence of water vapor. The ring-down time of this system was 1.068 μs, the detection sensitivity was 1 ppb, and the stability of the system was 0.13%. The detection principle of the integrated breath gas detection system follows Lambert–Beer’s law, which is an absolute measurement with very high detection accuracy, and was further validated by Gas Chromatography–Mass Spectrometer (GC-MS) testing. Significant differences in the response of the integrated breath gas detection system to simulated gases containing different concentrations of acetone indicate the potential of the system for the detection of trace amounts of acetone. Meanwhile, the monitoring of acetone during obesity treatment also signifies the feasibility of this system in the dynamic monitoring of physiological indicators, which is not only important for the optimization of the obesity treatment process but also promises to shed further light on the interaction between obesity treatment and physiological metabolism in medicine.

24 November 2023 in Entropy
Verified
Journal Article
Open access
PDF file
XXXIAOMAN XING
XIAOMAN XING
WDWen-Fei Dong
Wen-Fei Dong
RXRenjie Xiao
Renjie Xiao
MSMingxuan Song
Mingxuan Song
CJChenyu Jiang
Chenyu Jiang
Wearable technologies face challenges due to signal instability, hindering their usage. Thus, it is crucial to comprehend the connection between dynamic patterns in photoplethysmography (PPG) signals and cardiovascular health. In our study, we collected 401 multimodal recordings from two public databases, evaluating hemodynamic conditions like blood pressure (BP), cardiac output (CO), vascular compliance (C), and peripheral resistance (R). Using irregular-resampling auto-spectral analysis (IRASA), we quantified chaotic components in PPG signals and employed different methods to measure the fractal dimension (FD) and entropy. Our findings revealed that in surgery patients, the power of chaotic components increased with vascular stiffness. As the intensity of CO fluctuations increased, there was a notable strengthening in the correlation between most complexity measures of PPG and these parameters. Interestingly, some conventional morphological features displayed a significant decrease in correlation, indicating a shift from a static to dynamic scenario. Healthy subjects exhibited a higher percentage of chaotic components, and the correlation between complexity measures and hemodynamics in this group tended to be more pronounced. Causal analysis showed that hemodynamic fluctuations are main influencers for FD changes, with observed feedback in most cases. In conclusion, understanding chaotic patterns in PPG signals is vital for assessing cardiovascular health, especially in individuals with unstable hemodynamics or during ambulatory testing. These insights can help overcome the challenges faced by wearable technologies and enhance their usage in real-world scenarios.