Ching-Yuan Fann

Dr. Ching-Yuan Fann


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2016 in Tobacco Induced Diseases
Verified
Journal Article
Open access
DLDih-Ling Luh
Dih-Ling Luh
SCSam Li-Sheng Chen
Sam Li-Sheng Chen
AYAmy Ming-Fang Yen
Amy Ming-Fang Yen
SCSherry Yueh-Hsia Chiu
Sherry Yueh-Hsia Chiu
CFChing-Yuan Fann
Ching-Yuan Fann
TCTony Hsiu-Hsi Chen
Tony Hsiu-Hsi Chen
Background: A screening program provides a teachable moment for primary prevention such as encouraging smoking cessation. However, little is known about the efficacy of smoking cessation intervention delivered to the general population through a community-based screening program. Methods: A...

2 May 2019 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
SPSzu-Min Peng
Szu-Min Peng
HCHan-Mo Chiu
Han-Mo Chiu
HJHsiao-Hsuan Jen
Hsiao-Hsuan Jen
CHChen-Yang Hsu
Chen-Yang Hsu
SCSam Li-Sheng Chen
Sam Li-Sheng Chen
TCTony Hsiu-Hsi Chen
Tony Hsiu-Hsi Chen
Although fecal hemoglobin concentration (f-Hb) was highly associated with the risk of colorectal neoplasms, current studies on this subject are hampered by skewedness of the data and the ordinal property of f-Hb has not been well studied yet. Our aim was to develop a quantile-based method to estimate adjusted percentiles (median) of fecal hemoglobin concentration and their derived prediction for the risk of multistage outcomes of colorectal disease. We used a 6-year follow-up cohort of Taiwanese nationwide colorectal screening program with fecal immunochemical testing (FIT) to obtain fecal hemoglobin concentration and applied accelerated failure time multi-variable analyses to make the comparison of adjusted median and other percentitles of fecal hemoglobin across four categories of colorectal carcinogenesis. We then predicted the risk of colorectal neoplasms on the basis of the corresponding percentile values by using accelerated failure time model with Bayesian inversion method. The adjusted median fecal hemoglobin concentration of nonadvanced adenoma, advanced adenoma, and colorectal cancer were 57, 82, and 163 μg/g feces as opposed to 0 μg/g feces for the normal group. At 90 μg/g of f-Hb, the highly suspected cut-off for colorectal disease, the risks were 17% for non-advanced adenoma, 6% for advanced adenoma, and 9% for CRC. Life-time risks of each colorectal neoplasm were derived by percentiles of fecal hemoglobin concentration. Covariate-adjusted risk stratification for multistage outcomes of colorectal neoplasia were provided by using the quantiles of fecal hemoglobin concentration, yielding the estimated life-time risks of 25th to 75th quantitles, ranging from 0.5 to 44% for colorectal cancer, 0.2 to 46% for non-advanced adenoma, and 0.1 to 20% for advanced adenoma.

Verified
Journal Article
Open access
PDF file
SWSen-Te Wang
Sen-Te Wang
TLTing-Yu Lin
Ting-Yu Lin
TCTony Hsiu-Hsi Chen
Tony Hsiu-Hsi Chen
SCSam Li-Sheng Chen
Sam Li-Sheng Chen
CFChing-Yuan Fann
Ching-Yuan Fann
Background: While a population-wide strategy involving lifestyle changes and a high-risk strategy involving pharmacological interventions have been described, the recently proposed personalized medicine approach combining both strategies for the prevention of hypertension has increasingly gained attention. However, a cost-effectiveness analysis has been hardly addressed. This study was set out to build a Markov analytical decision model with a variety of prevention strategies in order to conduct an economic analysis for tailored preventative methods. Methods: The Markov decision model was used to perform an economic analysis of four preventative strategies: usual care, a population-based universal approach, a population-based high-risk approach, and a personalized strategy. In all decisions, the cohort in each prevention method was tracked throughout time to clarify the four-state model-based natural history of hypertension. Utilizing the Monte Carlo simulation, a probabilistic cost-effectiveness analysis was carried out. The incremental cost-effectiveness ratio was calculated to estimate the additional cost to save an additional life year. Results: The incremental cost-effectiveness ratios (ICER) for the personalized preventive strategy versus those for standard care were -USD 3317 per QALY gained, whereas they were, respectively, USD 120,781 and USD 53,223 per Quality-Adjusted Life Year (QALY) gained for the population-wide universal approach and the population-based high-risk approach. When the ceiling ratio of willingness to pay was USD 300,000, the probability of being cost-effective reached 74% for the universal approach and was almost certain for the personalized preventive strategy. The equivalent analysis for the personalized strategy against a general plan showed that the former was still cost-effective. Conclusions: To support a health economic decision model for the financial evaluation of hypertension preventative measures, a personalized four-state natural history of hypertension model was created. The personalized preventive treatment appeared more cost-effective than population-based conventional care. These findings are extremely valuable for making hypertension-based health decisions based on precise preventive medication.

10 July 2020 in Cancers
Verified
Journal Article
Open access
PDF file
RCRene Wei-Jung Chang
Rene Wei-Jung Chang
SCShu-Lin Chuang
Shu-Lin Chuang
CHChen-Yang Hsu
Chen-Yang Hsu
AYAmy Ming-Fang Yen
Amy Ming-Fang Yen
WWWendy Yi-Ying Wu
Wendy Yi-Ying Wu
TCTony Hsiu-Hsi Chen
Tony Hsiu-Hsi Chen
The aim was to evaluate how the inter-screening interval affected the performance of screening by mammographic appearances. This was a Swedish retrospective screening cohort study with information on screening history and mammography features in two periods (1977–1985 and 1996–2010). The pre-clinical incidence and the mean sojourn time (MST) for small breast cancer allowing for sensitivity by mammographic appearances were estimated. The percentage of interval cancer against background incidence (I/E ratio) was used to assess the performance of mammography screening by different inter-screening intervals. The sensitivity-adjusted MSTs (in years) were heterogeneous with mammographic features, being longer for powdery and crushed stone-like calcifications (4.26, (95% CI, 3.50–5.26)) and stellate masses (3.76, (95% CI, 3.15–4.53)) but shorter for circular masses (2.65, (95% CI, 2.06–3.55)) in 1996–2010. The similar trends, albeit longer MSTs, were also noted in 1977–1985. The I/E ratios for the stellate type were 23% and 32% for biennial and triennial screening, respectively. The corresponding figures were 32% and 43% for the circular type and 21% and 29% for powdery and crushed stone-like calcifications, respectively. Mammography-featured progressions of small invasive breast cancer provides a new insight into personalized quality assurance, surveillance, treatment and therapy of early-detected breast cancer.

1 March 2019 in International Journal of Technology Assessment in Health Care
Verified
Journal Article
Closed access
PDF file
HJHsiao-Hsuan Jen
Hsiao-Hsuan Jen
TWTsung-Hsi Wang
Tsung-Hsi Wang
HCHan-Mo Chiu
Han-Mo Chiu
SPSzu-Min Peng
Szu-Min Peng
CHChen-Yang Hsu
Chen-Yang Hsu
CFChing-Yuan Fann
Ching-Yuan Fann
Objectives: Population-based colorectal cancer (CRC) screening programs that use a fecal immunochemical test (FIT) are often faced with a noncompliance issue and its subsequent waiting time (WT) for those FIT positives complying with confirmatory diagnosis. We aimed to identify factors associated with both of the correlated problems in the same model.Methods: A total of 294,469 subjects, either with positive FIT test results or having a family history, collected from 2004 to 2013 were enrolled for analysis. We applied a hurdle Poisson regression model to accommodate the hurdle of compliance and also its related WT for undergoing colonoscopy while assessing factors responsible for the mixture of the two outcomes.Results: The effect on compliance and WT varied with contextual factors, such as geographic areas, type of screening units, and level of urbanization. The hurdle score, representing the risk score in association with noncompliance, and the WT score, reflecting the rate of taking colonoscopy, were used to classify subjects into each of three groups representing the degree of compliance and the level of health awareness.Conclusion: Our model was not only successfully applied to evaluating factors associated with the compliance and the WT distribution, but also developed into a useful assessment model for stratifying the risk and predicting whether and when screenees comply with the procedure of receiving confirmatory diagnosis given contextual factors and individual characteristics.

21 November 2020
Verified
Book Chapter
Closed access
PDF file
CFChing-Yuan Fann
Ching-Yuan Fann
ALAbbie Ting-Yu Lin
Abbie Ting-Yu Lin
RCRene Wei-Jung Chang
Rene Wei-Jung Chang
HCHsiu-Hsi Chen
Hsiu-Hsi Chen