Jacek Jaworski

Dr. Jacek Jaworski

Oil and Gas Institute - National Research Institute: Krakow, PL
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
JJJacek Jaworski
Jacek Jaworski
PKPaweł Kułaga
Paweł Kułaga
TBTomasz Blacharski
Tomasz Blacharski
Power-to-gas technology plays a key role in the success of the energy transformation. This paper addresses issues related to the legal and technical regulations specifying the rules for adding hydrogen to the natural gas network. The main issue reviewed is the effects of the addition of hydrogen to natural gas on the durability of diaphragm gas meters. The possibility of adding hydrogen to the gas network requires confirmation of whether, within the expected hydrogen concentrations, long-term operation of gas meters will be ensured without compromising their metrological properties and operational safety. Methods for testing the durability of gas meters applied at test benches and sample results of durability tests of gas meters are presented. Based on these results, a metrological and statistical analysis was carried out to establish whether the addition of hydrogen affects the durability of gas meters over time. The most important conclusion resulting from the conducted study indicates that, for the tested gas meter specimens, there was no significant metrological difference between the obtained changes of errors of indications after testing the durability of gas meters with varying hydrogen content (from 0% to 15%).

15 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Marco Dell'IsolaMarco Dell'Isola
Marco Dell'Isola
Giorgio FiccoGiorgio Ficco
Giorgio Ficco
LMLinda Moretti
Linda Moretti
JJJacek Jaworski
Jacek Jaworski
PKPaweł Kułaga
Paweł Kułaga
EKEwa Kukulska–Zając
Ewa Kukulska–Zając
Hydrogen is increasingly receiving a primary role as an energy vector in ensuring the achievement of the European decarbonization goals by 2050. In fact, Hydrogen could be produced also by electrolysis of water using renewable sources, such as photovoltaic and wind power, being able to perform the energy storage function, as well as through injection into natural gas infrastructures. However, hydrogen injection directly impacts thermodynamic properties of the gas itself, such as density, calorific value, Wobbe index, sound speed, etc. Consequently, this practice leads to changes in metrological behavior, especially in terms of volume and gas quality measurements. In this paper, the authors present an overview on the impact of hydrogen injection in natural gas measurements. In particular, the changes in thermodynamic properties of the gas mixtures with different H2 contents have been evaluated and the effects on the accuracy of volume conversion at standard conditions have been investigated both on the theoretical point of view and experimentally. To this end, the authors present and discuss the effect of H2 injection in gas networks on static ultrasonic domestic gas meters, both from a theoretical and an experimental point of view. Experimental tests demonstrated that ultrasonic gas meters are not significantly affected by H2 injection up to about 10%.

17 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
JJJacek Jaworski
Jacek Jaworski
ADAdrian Dudek
Adrian Dudek
Thermal gas meters represent a promising technology for billing customers for gaseous fuels, however, it is essential to ensure that measurement accuracy is maintained in the long term and in a broad range of operating conditions. The effect of hydrogen addition to natural gas will change the physicochemical properties of the mixture of natural gas and hydrogen. Such a mixture will be supplied through the gas system, to consumers, including households, where the amounts of received gas will be metered. The physicochemical properties of hydrogen, including the specific density or viscosity, differ significantly from those of the natural gas components, such as methane, ethane, propane, nitrogen, etc. Therefore, it is of utmost importance to establish the impact of the changes in the gas composition caused by the addition of hydrogen to natural gas on the metrological properties of household gas meters, including thermal gas meters. Furthermore, since household gas meters can be installed outdoors and, taking into account the fact that household gas meters are good heat exchangers, the influence of ambient and gas temperature on the metrological properties of those meters should be investigated. This article reviews a test bench and a testing method concerning errors of thermal gas meter indicators using air and natural gas, including the type containing hydrogen. The indication errors for thermal gas meters using air, natural gas and natural gas with an addition of 2%, 4%, 5%, 10% and 15% hydrogen were determined and then subjected to metrological analysis. Moreover, the test method and test bench are discussed and the results of tests on the impact of ambient and gas temperatures (‒25 °C and 55 °C, respectively) on the errors of indications of thermal gas meters are presented. Conclusions for distribution system operators in terms of gas meter selection were drawn based on the test results.

15 March 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
Giorgio FiccoGiorgio Ficco
Giorgio Ficco
MDM. Dell’isola
M. Dell’isola
GCGino Cortellessa
Gino Cortellessa
GGG. Grossi
G. Grossi
PKP. Kulaga
P. Kulaga
JJJacek Jaworski
Jacek Jaworski


17 March 2003 in Journal of Physics: Condensed Matter
Verified
Journal Article
Closed access
PDF file
HWH Wider
H Wider
VGV Gimple
V Gimple
WEW Evenson
W Evenson
GSG Schatz
G Schatz
JJJacek Jaworski
Jacek Jaworski
MEM Marsza Ek
M Marsza Ek