Frédérique Blanc-Béguin

Dr. Frédérique Blanc-Béguin

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2020 in Molecular Imaging and Biology
Verified
Journal Article
Closed access
PDF file
FBFrédérique Blanc-Béguin
Frédérique Blanc-Béguin
PEPhilippe Eliès
Philippe Eliès
PRPhilippe Robin
Philippe Robin
RTRaphaël Tripier
Raphaël Tripier
NKNelly Kervarec
Nelly Kervarec
PRPierre-Yves Le Roux
Pierre-Yves Le Roux

22 April 2022 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
FBFrédérique Blanc-Béguin
Frédérique Blanc-Béguin
SHSimon Hennebicq
Simon Hennebicq
PRPhilippe Robin
Philippe Robin
RTRaphael Tripier
Raphael Tripier
PSPierre-Yves Salaün
Pierre-Yves Salaün
PRPierre-Yves Le Roux
Pierre-Yves Le Roux
Lung ventilation/perfusion (V/Q) positron emission tomography-computed tomography (PET/CT) is a promising imaging modality for regional lung function assessment. The same carrier molecules as a conventional V/Q scan (i.e., carbon nanoparticles for ventilation and macro aggregated albumin particles for perfusion) are used, but they are labeled with gallium-68 (68Ga) instead of technetium-99m (99mTc). For both radiopharmaceuticals, various production processes have been proposed. This article discusses the challenges associated with the transition from 99mTc- to 68Ga-labelled radiopharmaceuticals. The various production and optimization processes for both radiopharmaceuticals are reviewed and discussed for optimal clinical use.

26 October 2022 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
PRPierre-Yves Le Roux
Pierre-Yves Le Roux
WSWolfgang M. Schafer
Wolfgang M. Schafer
FBFrédérique Blanc-Béguin
Frédérique Blanc-Béguin
Mark TulchinskyMark Tulchinsky
Mark Tulchinsky
Invented and first approved for clinical use in Australia 36 years ago, Technegas is the technology that enabled ventilation scintigraphy with 99mTc-labeled carbon nanoparticles (99mTc-CNP). The US Food and Drug Administration (FDA) has considered this technology for more than 30 years but only now is getting close to approving it. Meanwhile, more than 4.4 million patients benefited from this technology in 64 countries worldwide. The primary application of 99mTc-CNP ventilation imaging is the diagnostic evaluation for suspicion of pulmonary embolism using ventilation-perfusion quotient (V/Q) imaging. Because of 99mTc-CNP's long pulmonary residence, tomographic imaging emerged as the preferred V/Q methodology. The FDA-approved ventilation imaging agents are primarily suitable for planar imaging, which is less sensitive. After the FDA approval of Technegas, the US practice will likely shift to tomographic V/Q. The 99mTc-CNP use is of particular interest in the COVID-19 pandemic because it offers an option of a dry radioaerosol that takes approximately only 3 to 5 tidal breaths, allowing the shortest exposure to and contact with possibly infected patients. Indeed, countries where 99mTc-CNP was approved for clinical use continued using it throughout the COVID-19 pandemic without known negative viral transmission consequences. Conversely, the ventilation imaging was halted in most US facilities from the beginning of the pandemic. This review is intended to familiarize the US clinical nuclear medicine community with the basic science of 99mTc-CNP ventilation imaging and its clinical applications, including common artifacts and interpretation criteria for tomographic V/Q imaging for pulmonary embolism.

6 April 2023 in Cancers
Verified
Journal Article
Open access
PDF file
FPFanny PINOT
Fanny PINOT
DBDavid Bourhis
David Bourhis
VBVincent Bourbonne
Vincent Bourbonne
RFRomain Floch
Romain Floch
MMMaelle Mauguen
Maelle Mauguen
PRPierre-Yves Le Roux
Pierre-Yves Le Roux
Background: Gallium-68 lung perfusion PET/CT is an emerging imaging modality for the assessment of regional lung function, especially to optimise radiotherapy (RT) planning. A key step of lung functional avoidance RT is the delineation of lung functional volumes (LFVs) to be integrated into radiation plans. However, there is currently no consistent and reproducible delineation method for LFVs. The aim of this study was to develop and evaluate an automated delineation threshold method based on total lung function for LFVs delineation with Gallium-68 MAA lung PET/CT imaging. Material and Method: Patients prospectively enrolled in the PEGASUS trial—a pilot study assessing the feasibility of lung functional avoidance using perfusion PET/CT imaging for lung stereotactic body radiotherapy (SBRT) of primary or secondary lesion—were analysed. Patients underwent lung perfusion MAA-68Ga PET/CT imaging and pulmonary function tests (PFTs) as part of pre-treatment evaluation. LFVs were delineated using two methods: the commonly used relative to the maximal pixel value threshold method (pmax threshold method, X%pmax volumes) and a new approach based on a relative to whole lung function threshold method (WLF threshold method, FVX% volumes) using a dedicated iterative algorithm. For both methods, LFVs were expressed in terms of % of the anatomical lung volume (AV) and of % of the total lung activity. Functional volumes were compared for patients with normal PFTs and pre-existing airway disease. Results: 60 patients were analysed. Among the 48 patients who had PFTs, 31 (65%) had pre-existing lung disease. The pmax and WLF threshold methods clearly provided different functional volumes with a wide range of relative lung function for a given pmax volume, and conversely, a wide range of corresponding pmax values for a given WLF volume. The WLF threshold method provided more reliable and consistent volumes with much lower dispersion of LFVs as compared to the pmax method, especially in patients with normal PFTs. Conclusions: We developed a relative to whole lung function threshold segmentation method to delineate lung functional volumes on perfusion PET/CT imaging. The automated algorithm allows for reproducible contouring. This new approach, relatively unaffected by the presence of hot spots, provides reliable and consistent functional volumes, and is clinically meaningful for clinicians.

11 March 2023 in Cancers
Verified
Journal Article
Open access
PDF file
FLFrançois Lucia
François Lucia
MHMohamed Hamya
Mohamed Hamya
FPFanny Pinot
Fanny Pinot
GGGaëlle Goasduff
Gaëlle Goasduff
FBFrédérique Blanc-Béguin
Frédérique Blanc-Béguin
PRPierre-Yves Le Roux
Pierre-Yves Le Roux
The aim of this study was to assess the feasibility of sparing functional lung areas by integration of pulmonary functional mapping guided by 68Ga-perfusion PET/CT imaging in lung SBRT planification. Sixty patients that planned to receive SBRT for primary or secondary lung tumors were prospectively enrolled. Lung functional volumes were defined as the minimal volume containing 50% (FV50%), 70% (FV70%) and 90% (FV90%) of the total activity within the anatomical volume. All patients had a treatment planning carried out in 2 stages: an anatomical planning blinded to the PET results and then a functional planning respecting the standard constraints but also incorporating “lung functional volume” constraints. The mean lung dose (MLD) in functional volumes and the percentage of lung volumes receiving xGy (VxGy) within the lung functional volumes using both plans were calculated and compared. SBRT planning optimized to spare lung functional regions led to a significant reduction (p < 0.0001) of the MLD and V5 to V20 Gy in all functional volumes. Median relative difference of the MLD in the FV50%, FV70% and FV90% was −8.0% (−43.0 to 1.2%), −7.1% (−34.3 to 1.2%) and −5.7% (−22.3 to 4.4%), respectively. Median relative differences for VxGy ranged from −12.5% to −9.2% in the FV50%, −11.3% to −7.2% in the FV70% and −8.0% to −5.3% in the FV90%. This study shows the feasibility of significantly decreasing the doses delivered to the lung functional volumes using 68Ga-perfusion PET/CT while still respecting target volume coverage and doses to other organs at risk.

18 November 2021 in Frontiers in Nuclear Medicine
Verified
Journal Article
Open access
FBFrédérique Blanc-Béguin
Frédérique Blanc-Béguin
JMJulien Masset
Julien Masset
PRPhilippe Robin
Philippe Robin
RTRaphaël Tripier
Raphaël Tripier
SHSimon Hennebicq
Simon Hennebicq
PRPierre-Yves Le Roux
Pierre-Yves Le Roux
Lung PET/CT is a promising imaging modality for regional lung function assessment. Our aim was to develop and validate a fast, simple, and fully automated GMP compliant [68Ga]Ga-MAA labeling procedure, using a commercially available [99mTc]Tc-MAA kit, a direct gallium-68 eluate and including a purification of the [68Ga]Ga-MAA.Method: The synthesis parameters (pH, heating temperature) were manually determined. Automated 68Ga-labeling of MAA was then developed on a miniAIO (Trasis®, Ans, Belgium) module. An innovative automated process was developed for the purification. The process was then optimized and adapted to automate both the [68Ga]Ga-MAA synthesis and the isolation of gallium-68 eluate required for the pulmonary ventilation PET/CT.Results: The 15-min process demonstrated high reliability and reproducibility, with high synthesis yield (>95 %). Mean [68Ga]Ga-MAA radiochemical purity was 99 % ± 0.6 %. The 68Ga-labeled MAA particles size and morphology remained unchanged.Conclusion: A fast, user friendly, and fully automated process to produce GMP [68Ga]Ga-MAA for clinical use was developed. This automated process combining the advantages of using a non-modified MAA commercial kit, a gallium-68 eluate without pre-purification and an efficient final purification of the [68Ga]Ga-MAA may facilitate the implementation of lung PET/CT imaging in nuclear medicine departments.