Sebastian Żurek

Dr. Sebastian Żurek


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in Physica A: Statistical Mechanics and its Applications
Verified
Journal Article
Closed access
SŻSebastian Żurek
Sebastian Żurek
PGPrzemyslaw Guzik
Przemyslaw Guzik
SPSebastian Pawlak
Sebastian Pawlak
MKMarcin Kosmider
Marcin Kosmider
JPJaroslaw Piskorski
Jaroslaw Piskorski

1 July 2013
Verified
Conference Paper
Closed access
Paolo CastiglioniPaolo Castiglioni
Paolo Castiglioni
SŻSebastian Żurek
Sebastian Żurek
JPJaroslaw Piskorski
Jaroslaw Piskorski
MKMarcin Kosmider
Marcin Kosmider
PGPrzemyslaw Guzik
Przemyslaw Guzik
GMGiampiero Merati
Giampiero Merati
Sample Entropy (SampEn) is a popular method for assessing the unpredictability of biological signals. Its calculation requires to preliminarily set the tolerance threshold r and the embedding dimension m. Even if most studies select m=2 and r=0.2 times the signal standard deviation, this choice is somewhat arbitrary. Effects of different r and m values on SampEn have been rarely assessed, because of the high computational burden of this task. Recently, however, a fast algorithm for estimating correlation sums (Norm Component Matrix, NCM) has been proposed that allows calculating SampEn quickly over wide ranges of r and m. The aim of our work is to describe the structure of SampEn of physiological signals with different complex dynamics as a function of m and r and in relation to the correlation sum. In particular, we investigate whether the criterion of “maximum entropy” for selecting r previously proposed for Approximate Entropy, also applies to SampEn; and whether information from correlation sums provides indications for the choice of r and m. For this aim we applied the NCM algorithm on electromyographic and mechanomyographic signals during isometric muscle contraction, estimating SampEn over wide ranges of r (0.01≤ r ≤ 5) and m (from 1 to 11). Results indicate that the “maximum entropy” criterion to select r in Approximate Entropy cannot be applied to SampEn. However, the analysis of correlation sums alternatively suggests to choose r that at any m maximizes the number of “escaping vectors”, i.e., data points effectively contributing to the SampEn estimation.

24 April 2010 in Open Physics
Verified
Journal Article
Open access
PDF file
JPJaroslaw Piskorski
Jaroslaw Piskorski
PGPrzemyslaw Guzik
Przemyslaw Guzik
TKTomasz Krauze
Tomasz Krauze
SŻSebastian Żurek
Sebastian Żurek
We demonstrate the resonant-like behaviour of the cardiopulmonary system in healthy people occurring at the natural low frequency oscillations of 0.1 Hz, which are often visible in the continuous pressure waveform. These oscillations represent the spontaneous oscillatory activity of the vasomotor centre and are sometimes called the Mayer waves. These 10-second rhythms probably couple with forced breathing at the same frequency and cause the observed cardiopulmonary resonance phenomenon. We develop a new method to study this phenomenon, namely the averaged Lomb-Scargle periodogram method, which is shown to be very effective in enhancing common frequencies in a group of different time series and suppressing those which vary between datasets. Using this method we show that in cardiopulmonary resonance the cardiopulmonary system behaves in a very similar way to a simple mechanical or electrical oscillator, i.e. becomes highly regular and its averaged spectrum exhibits a clear dominant peak and harmonics. If the forcing frequency is higher than 0.1 Hz, the total power and the share of power in the dominant peak and harmonics are lower and the prominence of the dominant peak and its harmonics greatly diminishes. It is shown that the power contributions from different forcing frequencies follow the resonance curve.

10 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
DLDawid Lipski
Dawid Lipski
DMDorota Marzyńska
Dorota Marzyńska
PSPaulina Sytek
Paulina Sytek
PRPatrycja Rzesoś
Patrycja Rzesoś
ARAgnieszka Rabiza
Agnieszka Rabiza
Paweł UruskiPaweł Uruski
Paweł Uruski
One of the causes of hypertension is excess weight gain, which can also affect the course of this disease. Both the diagnosis and management of hypertension commonly use ambulatory blood pressure monitoring; the results of which correlate more strongly with cardiovascular diseases and cardiovascular death than office blood pressure monitoring. We evaluated blood pressure values and their variability from hour to hour to see if and when they differed between hypertensive patients with and without obesity. The study included 1345 patients who underwent 24 h ambulatory blood pressure monitoring and then were divided into groups according to body mass index and waist circumference. The obtained data were analyzed according to the subjects’ wake-up time, and short-term blood pressure variability parameters were calculated as the mean of the absolute values of the differences between consecutive measurements. The systolic blood pressure in obese subjects was significantly higher between 1 and 5 h before waking than in normal-weighted individuals. In turn, the variability in systolic and diastolic blood pressure was higher with increasing body mass index. The difference in systolic blood pressure values and blood pressure variability was most prominent in the last 5 h of sleep in obese patients.

1 January 2011 in Applied Soft Computing
Verified
Journal Article
Closed access
SŻSebastian Żurek
Sebastian Żurek

16 December 2024 in Entropy
Verified
Journal Article
Open access
PDF file
BBBartosz Mateusz Biczuk
Bartosz Mateusz Biczuk
SŻSebastian Żurek
Sebastian Żurek
SJSzymon Jurga
Szymon Jurga
ETElżbieta Turska
Elżbieta Turska
PGPrzemyslaw Guzik
Przemyslaw Guzik
JPJaroslaw Piskorski
Jaroslaw Piskorski
This study investigates whether heart rate asymmetry (HRA) parameters offer insights into sleep stages beyond those provided by conventional heart rate variability (HRV) and complexity measures. Utilizing 31 polysomnographic recordings, we focused exclusively on electrocardiogram (ECG) data, specifically the RR interval time series, to explore heart rate dynamics associated with different sleep stages. Employing both statistical techniques and machine learning models, with the Generalized Estimating Equation model as the foundational approach, we assessed the effectiveness of HRA in identifying and differentiating sleep stages and transitions. The models including asymmetric variables for detecting deep sleep stages, N2 and N3, achieved AUCs of 0.85 and 0.89, respectively, those for transitions N2–R, R–N2, i.e., falling in and out of REM sleep, achieved AUCs of 0.85 and 0.80, and those for W–N1, i.e., falling asleep, an AUC of 0.83. All these models were highly statistically significant. The findings demonstrate that HRA parameters provide significant, independent information about sleep stages that is not captured by HRV and complexity measures alone. This additional insight into sleep physiology potentially leads to a better understanding of hearth rhythm during sleep and devising more precise diagnostic tools, including cheap portable devices, for identifying sleep-related disorders.