Patrick Horve

Mr. Patrick Horve


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2020 in mSystems
Verified
Journal Article
Open access
PDF file
LDLeslie Dietz
Leslie Dietz
PHPatrick Horve
Patrick Horve
DCDavid A. Coil
David A. Coil
MFMark Fretz
Mark Fretz
JEJonathan Eisen
Jonathan Eisen
KWKevin Van Den Wymelenberg
Kevin Van Den Wymelenberg
With the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that results in coronavirus disease 2019 (COVID-19), corporate entities, federal, state, county, and city governments, universities, school districts, places of worship, prisons, health care facilities, assisted living organizations, daycares, homeowners, and other building owners and occupants have an opportunity to reduce the potential for transmission through built environment (BE)-mediated pathways. Over the last decade, substantial research into the presence, abundance, diversity, function, and transmission of microbes in the BE has taken place and revealed common pathogen exchange pathways and mechanisms.

15 July 2019 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Closed access
PHPatrick Horve
Patrick Horve
SLSavanna Lloyd
Savanna Lloyd
GMGwynne A. Mhuireach
Gwynne A. Mhuireach
LDLeslie Dietz
Leslie Dietz
MFMark Fretz
Mark Fretz
SISuzanne Lynn Ishaq
Suzanne Lynn Ishaq

31 August 2021 in mSystems
Verified
Journal Article
Open access
SISuzanne Lynn Ishaq
Suzanne Lynn Ishaq
FPFrancisco J. Parada
Francisco J. Parada
PWPatricia G. Wolf
Patricia G. Wolf
CBCarla Y. Bonilla
Carla Y. Bonilla
MCMegan A. Carney
Megan A. Carney
NMNicolae Morar
Nicolae Morar
Humans are inextricably linked to each other and our natural world, and microorganisms lie at the nexus of those interactions. Microorganisms form genetically flexible, taxonomically diverse, and biochemically rich communities, i.e., microbiomes that are integral to the health and development of macroorganisms, societies, and ecosystems.

22 February 2022 in mSystems
Verified
Journal Article
Open access
JRJake Robinson
Jake Robinson
NRNicole Redvers
Nicole Redvers
ACAraceli Camargo
Araceli Camargo
CBChristina A. Bosch
Christina A. Bosch
MBMartin F. Breed
Martin F. Breed
SISuzanne Lynn Ishaq
Suzanne Lynn Ishaq
Social and political policy, human activities, and environmental change affect the ways in which microbial communities assemble and interact with people. These factors determine how different social groups are exposed to beneficial and/or harmful microorganisms, meaning microbial exposure has an important socioecological justice context.

20 August 2019 in Indoor Air
Verified
Journal Article
Open access
PDF file
SVSamantha Velazquez
Samantha Velazquez
WGWillem Griffiths
Willem Griffiths
LDLeslie Dietz
Leslie Dietz
PHPatrick Horve
Patrick Horve
SNSusie Nunez
Susie Nunez
SISuzanne Lynn Ishaq
Suzanne Lynn Ishaq
Since the advent of soap, personal hygiene practices have revolved around removal, sterilization, and disinfection ‐ both of visible soil and microscopic organisms – for a myriad of cultural, aesthetic, or health‐related reasons. Cleaning methods and products vary widely in their recommended use, effectiveness, risk to users or building occupants, environmental sustainability, and ecological impact. Advancements in science and technology have facilitated in‐depth analyses of the indoor microbiome and studies in this field suggest that the traditional “scorched‐earth cleaning” mentality ‐ that surfaces must be completely sterilized and prevent microbial establishment ‐ may contribute to long‐term human health consequences. Moreover, the materials, products, activities, and microbial communities indoors all contribute to, or remove, chemical species to the indoor environment. This review examines the effects of cleaning with respect to the interaction of chemistry, indoor microbiology, and human health. Practical Implications Simple interventions, such as hand washing, can dramatically improve health and reduce infectious disease. Chemical intervention, while effective, may encourage the development of microbial resistance over time if not implemented properly. Microbial communities adapt, reassemble, and persist, and recent theory in microbial ecology suggests that curating microbial communities may be more sustainable than perpetually attempting to remove them.

29 June 2021 in Indoor Air
Verified
Journal Article
Open access
PDF file
PHPatrick Horve
Patrick Horve
LDLeslie G. Dietz
Leslie G. Dietz
MFMark Fretz
Mark Fretz
DCDavid A. Constant
David A. Constant
AWAndrew Wilkes
Andrew Wilkes
KWKevin Van Den Wymelenberg
Kevin Van Den Wymelenberg
Evidence continues to grow supporting the aerosol transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). To assess the potential role of heating, ventilation, and air conditioning (HVAC) systems in airborne viral transmission, this study sought to determine the viral presence, if any, on air handling units in a healthcare setting where coronavirus disease 2019 (COVID-19) patients were being treated. The presence of SARS-CoV-2 RNA was detected in approximately 25% of samples taken from ten different locations in multiple air handlers. While samples were not evaluated for viral infectivity, the presence of viral RNA in air handlers raises the possibility that viral particles can enter and travel within the air handling system of a hospital, from room return air through high-efficiency MERV-15 filters and into supply air ducts. Although no known transmission events were determined to be associated with these specimens, the findings suggest the potential for HVAC systems to facilitate transfer of virions to locations remote from areas where infected persons reside. These results are important within and outside of healthcare settings and may present necessary guidance for building operators of facilities that are not equipped with high-efficiency filtration. Furthermore, the identification of SARS-CoV-2 in HVAC components indicates the potential utility as an indoor environmental surveillance location.