Gabriele Schrag

Prof. Dr. Gabriele Schrag

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CDClaudia Durasiewicz
Claudia Durasiewicz
SGSophia Guentner
Sophia Guentner
PMPhilipp Klaus Maier
Philipp Klaus Maier
WHWolfgang Hölzl
Wolfgang Hölzl
GSGabriele Schrag
Gabriele Schrag
Microfluidic systems for medical applications necessitate reliable, wide flow range, and low leakage microvalves for flow path control. High design complexity of microvalves increases the risk of possible malfunction. We present a normally open microvalve based on energy-efficient piezoelectric actuation for high closing forces and micromachined valve seat trenches for reliable valve operation. A comprehensive investigation of influencing parameters is performed by extensive fluidic 3D finite element simulation, derivation of an analytical closed state leakage rate model, as well as fabrication and test of the microvalve. Additional valve seat coating and a high force actuator are introduced for further leakage reduction. The microvalve has a wide-open flow range as well as good sealing abilities in closed state. Extensive fatigue tests of 1 × 106 actuation cycles show that additional coating of the valve seat or increased actuator strength promote sealing performance stability. Analytical calculations of leakage are suitable to estimate experimentally obtained leakage rates and, along with computational fluidic dynamic (CFD) simulations, enable future microvalve design optimization. In conclusion, we demonstrate that the presented normally open microvalve is suitable for the design of safe and reliable microfluidic devices for medical applications.

14 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HOHesham Okeil
Hesham Okeil
GSGabriele Schrag
Gabriele Schrag
GWGerhard Wachutka
Gerhard Wachutka
We report on the development of a 600 °C withstanding low-noise apparatus, which enables high throughput magnetic field dependent characterization of semiconductor devices bonded to a ceramic substrate at very high temperatures. A novel and simple method for electrically contacting metal pads on the ceramic substrate is developed, which allows contacting many metal pads simultaneously on limited space. The apparatus can be used for a variety of high temperature experiments such as studying galvanomagnetic transport effects in devices and the characterization of SiC or GaN magnetic field sensors at very high temperatures. Furthermore, it can be used for performing very high temperature die attach processes. The apparatus has been successfully used to resolve magnetic field dependent current changes in a SiC pn diode ranging into the ppm scale at 500 °C.

14 March 2018 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
PDF file
TKThomas Kuenzig
Thomas Kuenzig
ADAlfons Dehe
Alfons Dehe
UKUlrich Krumbein
Ulrich Krumbein
GSGabriele Schrag
Gabriele Schrag
Maxing out the technological limits in order to satisfy the customers’ demands and obtain the best performance of micro-devices and-systems is a challenge of today’s manufacturers. Dedicated system simulation is key to investigate the potential of device and system concepts in order to identify the best design w.r.t. the given requirements. We present a tailored, physics-based system-level modeling approach combining lumped with distributed models that provides detailed insight into the device and system operation at low computational expense. The resulting transparent, scalable (i.e. reusable) and modularly composed models explicitly contain the physical dependency on all relevant parameters, thus being well suited for dedicated investigation and optimization of MEMS devices and systems. This is demonstrated for an industrial capacitive silicon microphone. The performance of such microphones is determined by distributed effects like viscous damping and inhomogeneous capacitance variation across the membrane as well as by system-level phenomena like package-induced acoustic effects and the impact of the electronic circuitry for biasing and read-out. The here presented model covers all relevant figures of merit and, thus, enables to evaluate the optimization potential of silicon microphones towards high fidelity applications.

28 June 2024 in IEEE Journal on Flexible Electronics
Verified
Journal Article
Closed access
NPNadine Philippin
Nadine Philippin
IKIngo Kuehne
Ingo Kuehne
GSGabriele Schrag
Gabriele Schrag
Recent advances in research and fabrication of flexible, stretchable or rather conformable electronics with printed conductive structures have enabled a wide range of applications. Various fields such as consumer electronics or wearable devices for health monitoring are affected by these achievements. Owing to gradually increasing demands on enhanced functionalities and an excellent deformability of such electronics, an investigation of appropriate hyperelastic materials and progressive manufacturing techniques are mandatory. In this article, a cost-efficient approach for fabrication of conformable electronics based on vacuum thermoforming with printed microscaled silver structures is presented. The patterns in form of conductive line arrays and meanders are realized by the emerging electrohydro-dynamic printing (EHD) technique which constitutes a promising alternative to established additive technologies due to the applicability of various printing media as well as its high material compatibility. Moreover, hyperelastic material models comprising the Mooney-Rivlin, Ogden, Neo-Hookean as well as the Yeoh model for description of stretchable thermoplastic polyurethane (TPU) during deformation are contrasted and general capabilities for design optimization of conductive structures are derived by means of numerical simulations. Based on the EHD printed metallic silver patterns on TPU with a subsequent transfer of the flat 100μm thick matrix towards a 3D-shaped electronic device by thermoforming, first demonstrators with a degree of deformation up to 57% are realized.

21 November 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
MSMartin Seidl
Martin Seidl
GSGabriele Schrag
Gabriele Schrag
Despite major advances in the field of actuator technology for microsystems, miniaturized microfluidic actuation systems for mobile devices are still not common in the market. We present a micropump concept and an associated mass flow sensor design, which, in combination, have the potential to form the basis for an integrated microfluidic development platform for microfluidic systems in general and microdosing systems in particular. The micropump combines the use of active valves with an electrostatic drive principle for the pump membrane and the valves, respectively. With a size of only 1.86 mm × 1.86 mm × 0.3 mm, the first prototypes are capable of pumping gaseous media at flow rates of up to 110 μL/min. A specific feature of the presented micropump is that the pumping direction is perpendicular to the chip surface. The corresponding flow sensor combines the principle of hot-wire anemometry with a very small footprint of only 1.4 mm × 1.4 mm × 0.4 mm. The main innovation is that the hot wires are fixed inside a through-hole in the substrate of the microchip, so that the flow direction of the fluid to be measured is perpendicular to the chip surface, which enables direct integration with the presented micropump. Detection thresholds of around 10 μL/min and measuring ranges of up to 20 mL/min can be achieved with the first prototypes, without dedicated evaluation electronics.

8 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
SASebastian Anzinger
Sebastian Anzinger
JMJohannes Manz
Johannes Manz
ADAlfons Dehe
Alfons Dehe
GSGabriele Schrag
Gabriele Schrag
We present a physics-based system-level model for optimizing a novel comb-based capacitive MEMS microphone towards high signal-to-noise ratios. The model includes non-linear coupling effects between the electrodes as well as the physical dependencies on relevant design parameters, thus enabling predictive statements w.r.t. the device performance. It is calibrated and validated by finite element simulations and laser Doppler vibrometer measurements of first prototypes. Being formulated as a generalized Kirchhoffian network, it can be implemented in a standard circuit simulation tool. The predicted signal-to-noise ratio of this concept reaches up to 78 dB(A), which significantly exceeds state-of-the-art devices.