Ludwik Halicz

Dr. Ludwik Halicz


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2008 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
LHLudwik Halicz
Ludwik Halicz
LYLu Yang
Lu Yang
NTNataliya Teplyakov
Nataliya Teplyakov
ABAvihu Burg
Avihu Burg
RSRalph Sturgeon
Ralph Sturgeon
YKYehoshua Kolodny
Yehoshua Kolodny
The present work describes methodology for the precise and accurate determination of chromium isotope ratios (50Cr/52Cr, 53Cr/52Cr, and 54Cr/52Cr) by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS). Mass discrimination and instrument drift are corrected for using a “standard–sample–standard” bracketing technique and normalization against NIST SRM 979 Cr(NO3)3·9H2O. The precisions (2s) of ratio measurements for 50Cr/52Cr, 53Cr/52Cr, and 54Cr/52Cr are ±0.11‰, ±0.06‰, and ±0.10‰ (110 ppm, 60 ppm and 100 ppm), respectively. For geological samples of relatively high concentration (300–17 000 ppm), Cr was separated from the matrix using columns of anion and cation exchange resins, providing a recovery of >95%. Inexplicably, for some geological samples, the aforementioned methodologies were not effective in reducing the concentrations of Fe and Ti to below 2% relative to the Cr concentration in the eluate. As a consequence, only 53Cr/52Cr was determined in such samples. Significant differences in isotope ratios were found among standard (NIST SRM 979), chemically pure metal chips of Cr (Alfa Aesar), a Late Proterozoic gabbro, a Cretaceous oil shale and natural products of combustion metamorphism of that oil shale. The igneous rocks and the pure metal have slightly negative δ53/ 52Cr values, the oil shale is +1.01‰, and the products of combustion metamorphism are all somewhat lighter, suggesting that the heavier isotopes of chromium were removed in the process of metamorphism.

1 January 1999 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
LHLudwik Halicz
Ludwik Halicz
ISIrina Segal
Irina Segal
OYOlga Yoffe
Olga Yoffe
Fifteen samples of fresh spring water from northern Israel were analyzed for extremely low REE concentrations. The concentration of LREE was between 0.02 and 13 ng l –1 and that of HREE was between 0.01 and 3 ng l –1 . The limit of detection was between 0.005 and 0.05 ng l –1 depending on the element. The efficiency of ultrasonic nebulization (USN) is dependent on the total dissolved solids in the samples and therefore the depression of the signal varies from sample to sample as a function of their chemical composition. This problem was solved by using rhenium as an internal standard. The recoveries (between 85 and 120%) found for the determination of REE in spiked natural samples together with the good agreement with known data for SRM SLRS-3 riverine water indicated the accuracy of the direct determination using the developed USN-ICP-MS procedure.

1 April 2017 in Talanta
Verified
Journal Article
Closed access
JKJakub Karasinski
Jakub Karasinski
EBEwa Bulska
Ewa Bulska
MWMarcin Wojciechowski
Marcin Wojciechowski
LHLudwik Halicz
Ludwik Halicz
AKAgnieszka Anna Krata
Agnieszka Anna Krata

22 March 2013 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
NSNetta Shalev
Netta Shalev
ISIrena Segal
Irena Segal
BLBoaz Lazar
Boaz Lazar
IGIttai Gavrieli
Ittai Gavrieli
JFJan Fietzke
Jan Fietzke
LHLudwik Halicz
Ludwik Halicz
δ88/86Sr values of standards and a variety of natural samples were measured by MC-ICP-MS using the double-spike (DS) method and compared to results obtained by the standard-sample-bracketing (SSB) method and to DS-TIMS measurements. The external reproducibility of the SRM987 measurements carried out by DS-MC-ICP-MS was 0.021‰ (1SD), slightly better than previously published DS-TIMS and SSB-MC-ICP-MS results. The value of the IAPSO seawater standard (0.388 ± 0.018; 2SEM) agrees with the results of the current SSB and DS-TIMS measurements and with previously published values. Using these values a variance-weighted mean for seawater was calculated (0.387 ± 0.002, 2SEM). Compared to measurements carried out by the SSB method, natural sample measurements by the DS method are more accurate and more precise. An excellent agreement between DS-MC-ICP-MS and DS-TIMS methods was demonstrated for δ88/86Sr determination in natural samples over a range of ∼0.5‰. The DS-TIMS δ88/86Sr results had a smaller standard error than the DS-MC-ICP-MS measurements but required a much longer acquisition time.

3 April 2020 in Molecules
Verified
Journal Article
Open access
PDF file
KWKatarzyna Wrobel
Katarzyna Wrobel
JKJakub Karasiński
Jakub Karasiński
ATAndrii Tupys
Andrii Tupys
MNMissael Antonio Arroyo Negrete
Missael Antonio Arroyo Negrete
LHLudwik Halicz
Ludwik Halicz
EBEwa Bulska
Ewa Bulska
Relatively few studies have been focused so far on magnesium–isotope fractionation during plant growth, element uptake from soil, root-to-leaves transport and during chlorophylls biosynthesis. In this work, maize and garden cress were hydroponically grown in identical conditions in order to examine if the carbon fixation pathway (C4, C3, respectively) might have impact on Mg-isotope fractionation in chlorophyll-a. The pigment was purified from plants extracts by preparative reversed phase chromatography, and its identity was confirmed by high-resolution mass spectrometry. The green parts of plants and chlorophyll-a fractions were acid-digested and submitted to ion chromatography coupled through desolvation system to multiple collector inductively coupled plasma-mass spectrometry. Clear preference for heavy Mg-isotopes was found in maize green parts (∆26Mgplant-nutrient 0.65, 0.74 for two biological replicates, respectively) and in chlorophyll-a (∆26Mgchlorophyll-plant 1.51, 2.19). In garden cress, heavy isotopes were depleted in green parts (∆26Mgplant-nutrient (−0.87)–(−0.92)) and the preference for heavy isotopes in chlorophyll-a was less marked relative to maize (∆26Mgchlorophyll-plant 0.55–0.52). The observed effect might be ascribed to overall higher production of energy in form of adenosine triphosphate (ATP), required for carbon fixation in C4 compared to C3, which could reduce kinetic barrier and make equilibrium fractionation prevailing during magnesium incorporation to protoporphyrin ring.

26 October 2007 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
TPThomas I. Platzner
Thomas I. Platzner
ISIrina Segal
Irina Segal
LHLudwik Halicz
Ludwik Halicz
The unique capabilities of multiple collector inductively coupled mass spectrometry (MC-ICP-MS) for high precision isotope ratio measurements in light elements as Li, Mg, Ca, and Cu are reviewed in this paper. These elements have been intensively studied at the Geological Survey of Israel (GSI) and other laboratories over the past few years, and the methods used to obtain high precision isotope analyses are discussed in detail. The scientific study of isotopic fractionation of these elements is significant for achieving a better understanding of geochemical and biochemical processes in nature and the environment.