Wavelet transforms are efficient tools for structural health monitoring (SHM) and damage detection. However, these methods are encountered with some limitations in practice. Thus, signal energy analysis is used as an alternative technique for damage detection. In this paper, discrete wavelet transforms (DWT) and Teager energy operator (TEO) is applied to the curvature of the mode shapes of the beams, and the locations of the damages are identified. The results show that in comparison with the discrete wavelet transform, the signal energy operator has better performance. This superiority in detecting the damages, especially near the supports of the beam, is obvious and has enough sensitivities in low damage intensities. Additionally, the damage detection in the cases that the response data are noisy is investigated. For this purpose, by adding low-intensity noises to the curvature of the mode shapes, the abilities of the mentioned methods are evaluated. The results indicate that each method is not individually efficient in the detection of damages in noisy conditions, but the combination of them under noisy conditions is more reliable
23 September 2020 in Fracture and Structural Integrity
This paper experimentally investigates the effect of steel and glass fibers on the engineering properties of concrete. To achieve this, 0.3%, 0.6%, and 0.9% by volume fraction of steel and glass fibers are added in concrete mixtures with water-to-cement (W/C) ratios 0.35 and 0.45. For each ratio of water to cement, 21 cubic samples for compressive strength tests, 14 cylindrical samples for tension strength tests, and also 14 prismatic samples for three-point flexural strength tests were prepared. The experimental results show that adding 0.3% to 0.9% % steel fibers for concrete increases simultaneously the compressive, tension, and also flexural strengths in comparison with plain concrete. Adding glass fibers only between 0.3% to 0.6% increases the compressive strength. The results reveal that the best range for reinforcing concrete with steel fiber is 0.3% to 0.9 % and glass fiber is 0.3% to 0.6 % by volume fraction of fiber to improve the engineering strengths concrete. As a rule of thumb, the tension and flexural strengths of concrete could be explained as 8% and 13% of the compressive strength, respectively.
Ground steel storage tanks are widely used in different industries. Regarding the significance of these structures, ensuring the proper performance of such structures in earthquakes needs evaluating their seismic performance. The present study examines the seismic behavior of an unanchored fluid storage system via ABAQUS after validation using an experimental model. Next, the uplift of the bottom sheet is studied using the accelerogram records of the 1940 El Centro and 1994 Northridge earthquakes. The overturning moment time history of the fluid storage system and the maximum overturning moments were obtained to identify their behavior. The results indicated that not bracing storage tanks leads to the uplift phenomenon. Finally, the maximum axial stress of the storage tank shell was compared with the values recommended in the design codes to control the buckling.
14 November 2019 in Fracture and Structural Integrity
Designing structural members is targeted in resisting against the loads such that the safety of considered structure is maintained regarding different conditions of loading. The method existing in ACI guideline is considered using load and resistance factors regardless of random nature of design parameters. Existing uncertainties in design parameters such as load and resistance have caused changes in safety of structure and the use of constant coefficients in different states of loading has often caused design unsafely. The present research has discussed the design of all the probabilities for reinforced concrete beams subjected to bending, shear and torsion stresses. For this, analytical relations of limit state have been developed to combine different stresses. Monte Carlo method is the method used to calculate safety measures, in which safety surface of American Concrete Institute (ACI) and different limit states have been calculated for three different sections (T-shape, rectangular shape and L-shape). The results of paper indicate that the safety index is considered in the range of 3 to 4 at different limit states. Load and resistance coefficients have been calculated in different safety indices and influence of load and resistance coefficients on American Concrete Institute (ACI) have been examined. Using the proposed method, designer enables to take an action for design by changing the conditions governing the problems such as dimensions, load and features of the section regarding the safety of structure. Further, under use of constant coefficients with sufficient information on composition of the considered loads, the designer enables to design and ratio of load and different limit states of the considered structure. Studying influence of changes of numbers in load and resistance coefficients on American Concrete Institute (ACI) has been mentioned as the major objective of the present research, indicating that resistance coefficient has more significantly influence on American Concrete Institute (ACI) in different loading compositions.