Armando Ugo Cavallo

Dr. Armando Ugo Cavallo

1. Department of Biomedicine and Prevention, University of Rome “Tor Vergata”, 00133 Rome, Italy
+1

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2024 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
TDTugba Akinci D'Antonoli
Tugba Akinci D'Antonoli
NMNathaniel Mercaldo
Nathaniel Mercaldo
AAAngel Alberich-Bayarri
Angel Alberich-Bayarri
BBBettina Baeßler
Bettina Baeßler
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Purpose: To propose a new quality scoring tool, METhodological RadiomICs Score (METRICS), to assess and improve research quality of radiomics studies. Methods: We conducted an online modified Delphi study with a group of international experts. It was performed in three consecutive stages: Stage#1, item preparation; Stage#2, panel discussion among EuSoMII Auditing Group members to identify the items to be voted; and Stage#3, four rounds of the modified Delphi exercise by panelists to determine the items eligible for the METRICS and their weights. The consensus threshold was 75%. Based on the median ranks derived from expert panel opinion and their rank-sum based conversion to importance scores, the category and item weights were calculated. Result: In total, 59 panelists from 19 countries participated in selection and ranking of the items and categories. Final METRICS tool included 30 items within 9 categories. According to their weights, the categories were in descending order of importance: study design, imaging data, image processing and feature extraction, metrics and comparison, testing, feature processing, preparation for modeling, segmentation, and open science. A web application and a repository were developed to streamline the calculation of the METRICS score and to collect feedback from the radiomics community. Conclusion: In this work, we developed a scoring tool for assessing the methodological quality of the radiomics research, with a large international panel and a modified Delphi protocol. With its conditional format to cover methodological variations, it provides a well-constructed framework for the key methodological concepts to assess the quality of radiomic research papers. Critical relevance statement: A quality assessment tool, METhodological RadiomICs Score (METRICS), is made available by a large group of international domain experts, with transparent methodology, aiming at evaluating and improving research quality in radiomics and machine learning. Key points: • A methodological scoring tool, METRICS, was developed for assessing the quality of radiomics research, with a large international expert panel and a modified Delphi protocol. • The proposed scoring tool presents expert opinion-based importance weights of categories and items with a transparent methodology for the first time. • METRICS accounts for varying use cases, from handcrafted radiomics to entirely deep learning-based pipelines. • A web application has been developed to help with the calculation of the METRICS score (https://metricsscore.github.io/metrics/METRICS.html) and a repository created to collect feedback from the radiomics community (https://github.com/metricsscore/metrics). Graphical

1 May 2019 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
ACArmando Ugo Cavallo
Armando Ugo Cavallo
IKIoannis Koktzoglou
Ioannis Koktzoglou
RERobert R. Edelman
Robert R. Edelman
RGRobert Gilkeson
Robert Gilkeson
GMGeorgeta Mihai
Georgeta Mihai
SRSanjay Rajagopalan
Sanjay Rajagopalan
Contrast-enhanced magnetic resonance angiography (MRA) provides excellent assessment of the peripheral arterial vasculature and is considered an important adjunctive diagnostic modality for the assessment of peripheral arterial disease. However, given the high prevalence of chronic kidney disease in patients with peripheral arterial disease, the association of gadolinium contrast media with nephrogenic systemic fibrosis, and recent concern with consequences of long-term deposition of gadolinium in the brain, there has been a renewed interest in noncontrast MRA approaches. Recent improvements in pulse sequences combined with instrumentation have facilitated the development of newer noncontrast MRA sequences that provide high spatial resolution, allowing the evaluation of distal (infrageniculate and pedal) vessels of importance in patients with critical limb ischemia. Further, many of these sequences are time efficient and versatile, allowing rapid evaluation of the entire lower extremity vasculature. In this comprehensive review, we outline historic techniques and compare these with newer approaches such as quiescent interval slice-selective MRA, 3-dimensional fast spin echo , and velocity-sensitive MRA that are emerging as an alternative to computed tomographic angiography or digital subtraction angiography for the evaluation of lower limb arteries in patients with peripheral arterial disease. Technical details and applications in clinical practice will be discussed.

14 May 2024 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
BKBurak Kocak
Burak Kocak
ABAlessandra Borgheresi
Alessandra Borgheresi
APAndrea Ponsiglione
Andrea Ponsiglione
AAAnna E. Andreychenko
Anna E. Andreychenko
ACArmando Ugo Cavallo
Armando Ugo Cavallo
Renato CuocoloRenato Cuocolo
Renato Cuocolo
Overall quality of radiomics research has been reported as low in literature, which constitutes a major challenge to improve. Consistent, transparent, and accurate reporting is critical, which can be accomplished with systematic use of reporting guidelines. The CheckList for EvaluAtion of Radiomics research (CLEAR) was previously developed to assist authors in reporting their radiomic research and to assist reviewers in their evaluation. To take full advantage of CLEAR, further explanation and elaboration of each item, as well as literature examples, may be useful. The main goal of this work, Explanation and Elaboration with Examples for CLEAR (CLEAR-E3), is to improve CLEAR’s usability and dissemination. In this international collaborative effort, members of the European Society of Medical Imaging Informatics−Radiomics Auditing Group searched radiomics literature to identify representative reporting examples for each CLEAR item. At least two examples, demonstrating optimal reporting, were presented for each item. All examples were selected from open-access articles, allowing users to easily consult the corresponding full-text articles. In addition to these, each CLEAR item’s explanation was further expanded and elaborated. For easier access, the resulting document is available at https://radiomic.github.io/CLEAR-E3/. As a complementary effort to CLEAR, we anticipate that this initiative will assist authors in reporting their radiomics research with greater ease and transparency, as well as editors and reviewers in reviewing manuscripts.Relevance statement Along with the original CLEAR checklist, CLEAR-E3 is expected to provide a more in-depth understanding of the CLEAR items, as well as concrete examples for reporting and evaluating radiomic research.Key points• As a complementary effort to CLEAR, this international collaborative effort aims to assist authors in reporting their radiomics research, as well as editors and reviewers in reviewing radiomics manuscripts.• Based on positive examples from the literature selected by the EuSoMII Radiomics Auditing Group, each CLEAR item explanation was further elaborated in CLEAR-E3.• The resulting explanation and elaboration document with examples can be accessed at https://radiomic.github.io/CLEAR-E3/. Graphical Abstract

1 January 2020 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
ACArmando Ugo Cavallo
Armando Ugo Cavallo
APAndrew J. Patterson
Andrew J. Patterson
RTRahul Thomas
Rahul Thomas
MAMohamad Amer Alaiti
Mohamad Amer Alaiti
GAGuilherme F. Attizzani
Guilherme F. Attizzani
SRsanjay Rajagopalan
sanjay Rajagopalan

15 April 2020 in Microorganisms
Verified
Journal Article
Open access
PDF file
DMDaniele De Meo
Daniele De Meo
VCValeria Calogero
Valeria Calogero
LALorenzo Are
Lorenzo Are
ACArmando Ugo Cavallo
Armando Ugo Cavallo
PPPietro Persiani
Pietro Persiani
CVCiro Villani
Ciro Villani
Periprosthetic joint infections (PJIs) are a cause of frequent implant failure in revision hip replacement surgery. The purpose of this study is to evaluate the onset of early postoperative infections in patients who underwent hip surgery with cementless prostheses treated with an antibiotic loaded hydrogel on their surface, in addition to systemic prophylaxis, and compare them to a control group. The secondary objective was to evaluate the onset of any local and systemic adverse effects and interference with bone ingrowth processes and functional recovery. A retrospective observational study was conducted on patients who underwent revision hip surgery by performing a 1:1 match between patients treated with an antibiotic hydrogel (ALH) and the control patients. The incidence of PJIs was assessed with a minimum of six months follow-up. Seventeen patients treated with the ALH were compared with 17 patients from the control group. No PJIs were reported in the ALH group versus the six cases encountered in the control group (p < 0.0001). No significant differences were reported with regard to prosthetic osseointegration and functional results, nor were there side effects in the ALH group. Despite the low sample size, the use of on-site prophylaxis with ALH has proven effective and safe in reducing the risk of PJIs in patients with a high risk for infections. Further studies are needed to validate these results in other implant-related surgeries.

1 March 2020 in Journal of Cardiovascular Medicine
Verified
Journal Article
Closed access
MCMarcello Chiocchi
Marcello Chiocchi
FRFrancesca Ricci
Francesca Ricci
MPMonia Pasqualetto
Monia Pasqualetto
FDFrancesca D’eRrico
Francesca D’eRrico
LBLeonardo Benelli
Leonardo Benelli
FRFrancesco Romeo
Francesco Romeo
Since 2002, transcatheter aortic valve implantation (TAVI) has revolutionized the treatment and prognosis of patients with aortic stenosis. A preprocedural assessment of the patient is vital for achieving optimal outcomes from the procedure. Retrospective ECG-gated cardiac computed tomography (CT) today it is the gold-standard imaging technique that provides three-dimensional images of the heart, thus allowing a rapid and complete evaluation of the morphology of the valve, ascending aorta, coronary arteries, peripheral access vessels, and prognostic factors, and also provides preprocedural coplanar fluoroscopic angle prediction to obtain complete assessment of the patient. The most relevant dimension in preprocedural planning of TAVI is the aortic annulus, which can determine the choice of prosthesis size. CT is also essential to identify patients with increased anatomical risk for coronary artery occlusion in Valve in Valve (ViV) procedures. Moreover, CT is very useful in the evaluation of late complications, such as leakage, thrombosis and displacements. At present, CT is the cornerstone imaging modality for the extensive and thorough work-up required for planning and performing each TAVI procedure, to achieve optimal outcomes. Both the CT procedure and analysis should be performed by trained and experienced personnel, with a radiological background and a deep understanding of the TAVI procedure, in close collaboration with the implantation team. An accurate pre-TAVI CT and post-processing for the evaluation of all the points recommended in this review allow a complete planning for the choice of the valve dimensions and type (balloon or self-expandable) and of the best percutaneous access.