Ana Catarina Pelicano

Ms. Ana Catarina Pelicano

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAna Catarina Pelicano
Ana Catarina Pelicano
MGMaria C. T. Gonçalves
Maria C. T. Gonçalves
DGDaniela M. Godinho
Daniela M. Godinho
TCTiago Castela
Tiago Castela
MOM. Lurdes Orvalho
M. Lurdes Orvalho
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
Breast cancer diagnosis using radar-based medical MicroWave Imaging (MWI) has been studied in recent years. Realistic numerical and physical models of the breast are needed for simulation and experimental testing of MWI prototypes. We aim to provide the scientific community with an online repository of multiple accurate realistic breast tissue models derived from Magnetic Resonance Imaging (MRI), including benign and malignant tumours. Such models are suitable for 3D printing, leveraging experimental MWI testing. We propose a pre-processing pipeline, which includes image registration, bias field correction, data normalisation, background subtraction, and median filtering. We segmented the fat tissue with the region growing algorithm in fat-weighted Dixon images. Skin, fibroglandular tissue, and the chest wall boundary were segmented from water-weighted Dixon images. Then, we applied a 3D region growing and Hoshen-Kopelman algorithms for tumour segmentation. The developed semi-automatic segmentation procedure is suitable to segment tissues with a varying level of heterogeneity regarding voxel intensity. Two accurate breast models with benign and malignant tumours, with dielectric properties at 3, 6, and 9 GHz frequencies have been made available to the research community. These are suitable for microwave diagnosis, i.e., imaging and classification, and can be easily adapted to other imaging modalities.

17 May 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
APAna Catarina Pelicano
Ana Catarina Pelicano
MGMaria C T Gonçalves
Maria C T Gonçalves
TCTiago Castela
Tiago Castela
MOM Lurdes Orvalho
M Lurdes Orvalho
NANuno A. M. Araujo
Nuno A. M. Araujo
DGDaniela M Godinho
Daniela M Godinho
The diagnosis of breast cancer through MicroWave Imaging (MWI) technology has been extensively researched over the past few decades. However, continuous improvements to systems are needed to achieve clinical viability. To this end, the numerical models employed in simulation studies need to be diversified, anatomically accurate, and also representative of the cases in clinical settings. Hence, we have created the first open-access repository of 3D anatomically accurate numerical models of the breast, derived from 3.0T Magnetic Resonance Images (MRI) of benign breast disease and breast cancer patients. The models include normal breast tissues (fat, fibroglandular, skin, and muscle tissues), and benign and cancerous breast tumors. The repository contains easily reconfigurable models which can be tumor-free or contain single or multiple tumors, allowing complex and realistic test scenarios needed for feasibility and performance assessment of MWI devices prior to experimental and clinical testing. It also includes an executable file which enables researchers to generate models incorporating the dielectric properties of breast tissues at a chosen frequency ranging from 3 to 10 GHz, thereby ensuring compatibility with a wide spectrum of research requirements and stages of development for any breast MWI prototype system. Currently, our dataset comprises MRI scans of 55 patients, but new exams will be continuously added.

12 September 2024 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Closed access
APAna Catarina Pelicano
Ana Catarina Pelicano
Maria Manuela GasparMaria Manuela Gaspar
Maria Manuela Gaspar
Catarina ReisCatarina Reis
Catarina Reis
NANuno A. M. Araujo
Nuno A. M. Araujo
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
DGDaniela M. Godinho
Daniela M. Godinho
Complex permittivity measurements of murine melanoma tumours were performed via open-ended coaxial probe technique for frequencies ranging from 500 MHz to 8.5 GHz. The measurements were conducted in five mice containing a melanoma tumour each, while the animals were under anaesthesia. Two different measurement methodologies were employed. Eighty-six in vivo measurements of melanoma's permittivity were collected with the open-ended coaxial probe placed directly on the tumours. A one-pole Cole-Cole model was fitted to the melanoma's median curve. The data were organised in a nested structure; hence generalised linear mixed-effects models were employed over the entire frequency band to evaluate between-tumour and between-location variabilities. Results revealed a larger between-location variability, indicating intra-tumoral heterogeneity, which was visually confirmed. Additionally, generalised linear mixed-effect models were also employed to assess the measurement methodologies, for 500 MHz, 4.5 GHz, and 8.5 GHz.

4 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
APAna Catarina Pelicano
Ana Catarina Pelicano
Raquel ConceiçãoRaquel Conceição
Raquel Conceição
The development of 3D anthropomorphic head and neck phantoms is of crucial and timely importance to explore novel imaging techniques, such as radar-based MicroWave Imaging (MWI), which have the potential to accurately diagnose Cervical Lymph Nodes (CLNs) in a neoadjuvant and non-invasive manner. We are motivated by a significant diagnostic blind-spot regarding mass screening of LNs in the case of head and neck cancer. The timely detection and selective removal of metastatic CLNs will prevent tumor cells from entering the lymphatic and blood systems and metastasizing to other body regions. The present paper describes the developed phantom generator which allows the anthropomorphic modelling of the main biological tissues of the cervical region, including CLNs, as well as their dielectric properties, for a frequency range from 1 to 10 GHz, based on Magnetic Resonance images. The resulting phantoms of varying complexity are well-suited to contribute to all stages of the development of a radar-based MWI device capable of detecting CLNs. Simpler models are essential since complexity could hinder the initial development stages of MWI devices. Besides, the diversity of anthropomorphic phantoms resulting from the developed phantom generator can be explored in other scientific contexts and may be useful to other medical imaging modalities.