Sara Elhadad

Mrs. Sara Elhadad

Marcel Breuer Doctoral School, Faculty of Engineering and Information Technology, University of Pécs, Boszorkány u. 2, H-7624 Pécs, Hungary, and Energia Design Building Technology Research Group, Szentágothai Research Centre, Ifjúság útja 20, H-7624 Pécs,
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
SESara Elhadad
Sara Elhadad
CRChro Hama Radha
Chro Hama Radha
IKIstván Kistelegdi
István Kistelegdi
BBBalint Baranyai
Balint Baranyai
GJGyergyák János
Gyergyák János
Accurate building physics performance analysis requires time-consuming, detailed modeling, and calculation time requirement. This paper evaluates the impact of model simplifications on thermal and visual comfort as well as energy performance. In the framework of dynamic zonal thermal simulation, a case study of a residential building in hot climate is investigated. A detailed model is created and simplified through four scenarios, by incrementally reducing the number of thermal zones from modeling every space as a separate zone to modeling the building as a single zone. The differences of total energy and comfort performance in the detailed and simplified models are analyzed to evaluate the grade of the simplifications’ accuracy. The results indicate that all simplification scenarios present a marginal average deviation in total energy demand and thermal comfort by less than 20%. Combining rooms with similar thermal features into a zone presents the optimal scenario, while the worst scenario is the single-zone model. Results showed that thermal zone merging as a simulation simplification method has its limitations as well, whereas a too intensive simplification can lead to undesired error rates. The method is well applicable in further early-stage design and development tasks, specifically in large-scale projects.

1 December 2018 in Pollack Periodica
Verified
Journal Article
Closed access
PDF file
SESara Elhadad
Sara Elhadad
BBBalint Baranyai
Balint Baranyai
GJGyergyák János
Gyergyák János
The energy consumption of residential buildings represents the majority part of energy usage in Egypt. The aim of this study is to assess the energy performance of a dwelling in New Minia City, Egypt through different orientations. The energy consumption of the case study building is 52560 kWh annually. However, this energy demand could be reduced by 5.8% if the building is oriented to the north direction. The difference of the energy consumption between the best and the worst building orientations, North and South, respectively, reached up to 7.5%. The location of the actual building has a noticeable effect on the energy consumption.

19 December 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
SESara Elhadad
Sara Elhadad
Zoltan OrbanZoltan Orban
Zoltan Orban
Sensitivity analysis is crucial in building energy assessments. It is used to determine the major variables influencing building thermal performance, using both observational research and energy simulation models. This study investigates the most influential envelope design parameters on the thermal performance of a typical residential building in Budapest, Hungary. Sensitivity analysis is used in conjunction with the IDA-Indoor and Climate Energy (IDA-ICE 4.8) simulation tool to assess the effects of 33 envelope design parameters for energy consumption and carbon dioxide concentrations. The input parameters include thickness, materials, density, specific heat and thermal conductivity of the basement, exterior floor, interior floor, exterior wall, interior wall, roof, ground slab, glazing type, and infiltration rate. The results show that exterior floor materials have the biggest impact on annual delivered energy for heating and cooling, whereas the density of all structural elements and thickness of the basement, exterior floors, interior floors, and walls have minimal effects on energy consumption. It is also shown that the impact of all investigated parameters is not sensitive to the carbon dioxide concentration in the building. The authors consider that the findings of the paper assist designers to assess the performance of existing buildings and more efficiently generating alternative solutions in the energetic retrofitting of existing and energy design of new residential buildings.

18 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
ÁKÁdám Katona
Ádám Katona
HXHuang Xuan
Huang Xuan
SESara Elhadad
Sara Elhadad
IKIstván Kistelegdi
István Kistelegdi
IHIstvan Haber
Istvan Haber
Natural driven ventilation is a widely used technique in hot and arid climate, but it is rarely known that it can lead to significant energy saving in a moderate climate too. In this paper, an existing building is presented that was designed with a passive air conduction system (PACS), where wind and buoyancy effects induce air to be exchanged without external energy needs. The aim is to show that the design methodology, using numerical simulation to give accurate results, is able to use them in further developments. Due to this design process, the specific building possesses numerous special properties, including airflow accelerating elements, solar-heated “chimneys”, and the indoor heat sources coming from the industrial technology. As the building has been constructed and was equipped with around 750 sensors (integrated and manual), it is possible to analyze the ongoing physical phenomenon in a highly detailed way and to collect the experienced dataset for further investigations. The current study carries out a complex validation of the design and the used numerical methods to give general design rules for further PACS design and support following investigations, e.g., occupant comfort prediction or latent heat storage calculation. The experiences showed that the developed computational fluid dynamics technique gives a below 99% accuracy in the velocity and the temperature field, and approximately 85% accuracy in the volume flow values, resulting in a good prediction for aerodynamic characterization of buildings, i.e., passive ventilation air exchange rate.

15 July 2025 in Alexandria Engineering Journal
Verified
Journal Article
Open access
HEHany S. El-Mesery
Hany S. El-Mesery
AEAhmed H. ElMesiry
Ahmed H. ElMesiry
OAOluwasola Abayomi Adelusi
Oluwasola Abayomi Adelusi
ZHZicheng Hu
Zicheng Hu
SESara Elhadad
Sara Elhadad

1 August 2020 in Pollack Periodica
Verified
Journal Article
Open access
PDF file
MRMessaouda Rais
Messaouda Rais
SESara Elhadad
Sara Elhadad
ABAdel Boumerzoug
Adel Boumerzoug
BBBalint Baranyai
Balint Baranyai
Day-lighting studies in buildings play a major role in indoor environmental investigation and can be conducted at the early stages of building design. Window position significantly affects day-lighting performance. This paper assessed the impacts of the window position on the visual comfort through two main factors; daylight factor and light uniformity in the hot and dry climate zone. In this study different window positions have been examined to achieve optimal visual comfort, using a dynamic simulation through Vi-suit plugin for Blender 3D software that controls the external application Radiance software. The results revealed that the window position at sill start from 1.4 m of a room characterized by (4.30 m × 3.00 m × 3.00 m) is the best compromising solution that complies with the daylight factor and light uniformity standards in the indoor environment. The findings of this study provide a more detailed and comprehensive analysis of the window design for architects/designers in the early building design stages in the hot and dry climate region.