Jianbo Tang

Mr. Jianbo Tang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
DPDmitry D. Postnov
Dmitry D. Postnov
JTJianbo Tang
Jianbo Tang
Şefik Evren ErdenerŞefik Evren Erdener
Şefik Evren Erdener
KKKıvılcım Kılıç
Kıvılcım Kılıç
DBDavid A. Boas
David A. Boas
Nature of red blood cell dynamics and light scattering interactions unraveled to accurately probe cerebral blood flow.

23 November 2017 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Closed access
Şefik Evren ErdenerŞefik Evren Erdener
Şefik Evren Erdener
JTJianbo Tang
Jianbo Tang
ASAmir Sajjadi
Amir Sajjadi
KKKıvılcım Kılıç
Kıvılcım Kılıç
SKSreekanth Kura
Sreekanth Kura
DBDavid A Boas
David A Boas
Optical coherence tomography (OCT) allows label-free imaging of red blood cell (RBC) flux within capillaries with high spatio-temporal resolution. In this study, we utilized time-series OCT-angiography to demonstrate interruptions in capillary RBC flux in mouse brain in vivo. We noticed ∼7.5% of ∼200 capillaries had at least one stall in awake mice with chronic windows during a 9-min recording. At any instant, ∼0.45% of capillaries were stalled. Average stall duration was ∼15 s but could last over 1 min. Stalls were more frequent and longer lasting in acute window preparations. Further, isoflurane anesthesia in chronic preparations caused an increase in the number of stalls. In repeated imaging, the same segments had a tendency to stall again over a period of one month. In awake animals, functional stimulation decreased the observance of stalling events. Stalling segments were located distally, away from the first couple of arteriolar-side capillary branches and their average RBC and plasma velocities were lower than nonstalling capillaries within the same region. This first systematic analysis of capillary RBC stalls in the brain, enabled by rapid and continuous volumetric imaging of capillaries with OCT-angiography, will lead to future investigations of the potential role of stalling events in cerebral pathologies.

5 May 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JTJianbo Tang
Jianbo Tang
JCJason E. Coleman
Jason E. Coleman
XDXianjin Dai
Xianjin Dai
HJHuabei Jiang
Huabei Jiang
Understanding the relationship between brain function and behavior remains a major challenge in neuroscience. Photoacoustic tomography (PAT) is an emerging technique that allows for noninvasive in vivo brain imaging at micrometer-millisecond spatiotemporal resolution. In this article, a novel, miniaturized 3D wearable PAT (3D-wPAT) technique is described for brain imaging in behaving rats. 3D-wPAT has three layers of fully functional acoustic transducer arrays. Phantom imaging experiments revealed that the in-plane X-Y spatial resolutions were ~200 μm for each acoustic detection layer. The functional imaging capacity of 3D-wPAT was demonstrated by mapping the cerebral oxygen saturation via multi-wavelength irradiation in behaving hyperoxic rats. In addition, we demonstrated that 3D-wPAT could be used for monitoring sensory stimulus-evoked responses in behaving rats by measuring hemodynamic responses in the primary visual cortex during visual stimulation. Together, these results show the potential of 3D-wPAT for brain study in behaving rodents.

17 June 2015 in Journal of Cerebral Blood Flow & Metabolism
Verified
Journal Article
Closed access
JTJianbo Tang
Jianbo Tang
LXLei Xi
Lei Xi
JZJunli Zhou
Junli Zhou
HHHua Huang
Hua Huang
TZTao Zhang
Tao Zhang
HJHuabei Jiang
Huabei Jiang
We present a noninvasive method of photoacoustic tomography (PAT) for imaging cerebral hemodynamics in awake-moving rats. The wearable PAT (wPAT) system has a size of 15 mm in height and 33 mm in diameter, and a weight of ~ 8 g (excluding cabling). The wPAT achieved an imaging rate of 3.33 frames/s with a lateral resolution of 243 μm. Animal experiments were designed to show wPAT feasibility for imaging cerebral hemodynamics on awake-moving animals. Results showed that the cerebral oxy-hemoglobin and deoxy-hemoglobin changed significantly in response to hyperoxia; and, after the injection of pentylenetetrazol (PTZ), cerebral blood volume changed faster over time and larger in amplitude for rats in awake-moving state compared with rats under anesthesia. By providing a light-weight, high-resolution technology for in vivo monitoring of cerebral hemodynamics in awake-behaving animals, it will be possible to develop a comprehensive understanding on how activity alters hemodynamics in normal and diseased states.

6 June 2023 in Journal of the American Heart Association
Verified
Journal Article
Open access
CSChristian Staehr
Christian Staehr
JGJohn T. Giblin
John T. Giblin
EGEugenio Gutiérrez‐Jiménez
Eugenio Gutiérrez‐Jiménez
HGHalvor Guldbrandsen
Halvor Guldbrandsen
JTJianbo Tang
Jianbo Tang
VMVladimir Matchkov
Vladimir Matchkov
Background: Normal brain function depends on the ability of the vasculature to increase blood flow to regions with high metabolic demands. Impaired neurovascular coupling, such as the local hyperemic response to neuronal activity, may contribute to poor neurological outcome after stroke despite successful recanalization, that is, futile recanalization. Methods and Results: Mice implanted with chronic cranial windows were trained for awake head‐fixation before experiments. One‐hour occlusion of the anterior middle cerebral artery branch was induced using single‐vessel photothrombosis. Cerebral perfusion and neurovascular coupling were assessed by optical coherence tomography and laser speckle contrast imaging. Capillaries and pericytes were studied in perfusion‐fixed tissue by labeling lectin and platelet‐derived growth factor receptor β. Arterial occlusion induced multiple spreading depolarizations over 1 hour associated with substantially reduced blood flow in the peri‐ischemic cortex. Approximately half of the capillaries in the peri‐ischemic area were no longer perfused at the 3‐ and 24‐hour follow‐up (45% [95% CI, 33%–58%] and 53% [95% CI, 39%–66%] reduction, respectively; P <0.0001), which was associated with contraction of an equivalent proportion of peri‐ischemic capillary pericytes. The capillaries in the peri‐ischemic cortex that remained perfused showed increased point prevalence of dynamic flow stalling (0.5% [95% CI, 0.2%–0.7%] at baseline, 5.1% [95% CI, 3.2%–6.5%] and 3.2% [95% CI, 1.1%–5.3%] at 3‐ and 24‐hour follow‐up, respectively; P =0.001). Whisker stimulation at the 3‐ and 24‐hour follow‐up led to reduced neurovascular coupling responses in the sensory cortex corresponding to the peri‐ischemic region compared with that observed at baseline. Conclusions: Arterial occlusion led to contraction of capillary pericytes and capillary flow stalling in the peri‐ischemic cortex. Capillary dysfunction was associated with neurovascular uncoupling. Neurovascular coupling impairment associated with capillary dysfunction may be a mechanism that contributes to futile recanalization. Hence, the results from this study suggest a novel treatment target to improve neurological outcome after stroke.

30 January 2020 in Neurophotonics
Verified
Journal Article
Open access
PDF file
SSSmrithi Sunil
Smrithi Sunil
Şefik Evren ErdenerŞefik Evren Erdener
Şefik Evren Erdener
BLBlaire S. Lee
Blaire S. Lee
DPDmitry Postnov
Dmitry Postnov
JTJianbo Tang
Jianbo Tang
Kıvılcım KılıçKıvılcım Kılıç
Kıvılcım Kılıç
Stroke is the leading cause of long-term disability and the second leading cause of death worldwide.1 Strokes are either ischemic, which account for over 85% of all strokes and occur due to the interruption of blood flow caused by thrombosis, or hemorrhagic, which occur due to bleeding.2,3 During ischemic stroke, a reduction or complete loss in blood supply causes a starved oxygen environment and leads to neuronal damage within minutes and ultimately to sensorimotor and cognitive impairment.2,3