Lucia Schiavon

Mrs. Lucia Schiavon

University of Padua, Padua, Italy
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
Giulia BrunelloGiulia Brunello
Giulia Brunello
SPSourav Panda
Sourav Panda
LSLucia Schiavon
Lucia Schiavon
SSStefano Sivolella
Stefano Sivolella
Lisa BiasettoLisa Biasetto
Lisa Biasetto
Massimo Del FabbroMassimo Del Fabbro
Massimo Del Fabbro
Bioceramic scaffolds are appealing for alveolar bone regeneration, because they are emerging as promising alternatives to autogenous and heterogenous bone grafts. The aim of this systematic review is to answer to the focal question: in critical-sized bone defects in experimental animal models, does the use of a bioceramic scaffolds improve new bone formation, compared with leaving the empty defect without grafting materials or using autogenous bone or deproteinized bovine-derived bone substitutes? Electronic databases were searched using specific search terms. A hand search was also undertaken. Only randomized and controlled studies in the English language, published in peer-reviewed journals between 2013 and 2018, using critical-sized bone defect models in non-medically compromised animals, were considered. Risk of bias assessment was performed using the SYRCLE tool. A meta-analysis was planned to synthesize the evidence, if possible. Thirteen studies reporting on small animal models (six studies on rats and seven on rabbits) were included. The calvarial bone defect was the most common experimental site. The empty defect was used as the only control in all studies except one. In all studies the bioceramic materials demonstrated a trend for better outcomes compared to an empty control. Due to heterogeneity in protocols and outcomes among the included studies, no meta-analysis could be performed. Bioceramics can be considered promising grafting materials, though further evidence is needed.

29 August 2022 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
LSLucia Schiavon
Lucia Schiavon
APAlessandro Perini
Alessandro Perini
Giulia BrunelloGiulia Brunello
Giulia Brunello
GFGiada Ferrante
Giada Ferrante
Massimo Del FabbroMassimo Del Fabbro
Massimo Del Fabbro
SSStefano Sivolella
Stefano Sivolella
Objective: This systematic review aimed at assessing the effect of the repositioned bone lid on bone augmentation in lateral sinus lift in pre-clinical in vivo and clinical studies. Secondary aims were to report on the healing of the bone window and to assess the implant survival rate.Material and methods: Animal and human studies comparing lateral maxillary sinus floor elevation in combination or not with the repositioned bone lid were retrieved from MEDLINE (PubMed), Web of Science and Cochrane online library. Studies published in English up to April 2022 and reporting on histological and/or radiographic outcomes were considered. Case reports, case series and reviews were excluded. A hand search was also conducted. Risk of bias was assessed and meta-analysis performed to investigate the effect of the bone lid on new bone formation.Results: After screening, 5 animal studies (4 in rabbits, 1 in sheep) and 2 clinical studies (1 RCT, 1 case–control) were included. Meta-analysis confirmed a higher new bone formation in rabbits at 2 and 8 weeks using the bone lid. The two clinical studies investigated lateral sinus lift with concomitant implant placement and reported similar results and high short-term implant success rate in both test and control groups.Conclusions: The meta-analysis provided moderate evidence that the repositioned bone lid favored the formation of new bone to a higher extent as compared to resorbable membranes in animal studies. Implant success seems not to be influenced by the technique in the short term.

Verified
Journal Article
Open access
PDF file
SSStefano Sivolella
Stefano Sivolella
Giulia BrunelloGiulia Brunello
Giulia Brunello
SPSourav Panda
Sourav Panda
LSLucia Schiavon
Lucia Schiavon
FKFouad Khoury
Fouad Khoury
Massimo Del FabbroMassimo Del Fabbro
Massimo Del Fabbro
This scoping review aimed at reporting the outcomes of the bone lid technique in oral surgery in terms of bone healing, ridge preservation, and incidence of complications. Bone-cutting instruments and stabilization methods were also considered. PubMed, Scopus, and the Cochrane Register of Controlled Trials were searched using a combination of terms, including bone lid, bony window, piezosurgery, microsaw, cysts, endodontic surgery, impacted teeth, and maxillary sinus. A hand search was also performed. The last search was conducted on 30 November 2021. No date limitation was set. Searches were restricted to human clinical studies published in English. All types of study design were considered except reviews and case reports. After a two-step evaluation, 20 (2 randomized studies, 2 case-control studies, 3 cohort studies, 13 case series) out of 647 screened studies were included, reporting on 752 bone lid procedures. The bone lid technique was associated with favorable bone healing when compared to other methods, and with a very low incidence of major complications. Clinical indications, surgical procedures, study design, follow-up duration, and outcomes varied among the studies. Overall, favorable outcomes were reported using the bone lid approach, though evidence-based studies were scarce.

10 July 2025 in Journal of Periodontal Research
Verified
Journal Article
Open access
LSLucia Schiavon
Lucia Schiavon
Leonardo ManciniLeonardo Mancini
Leonardo Mancini
ESEugenia Settecase
Eugenia Settecase
RJRonald E. Jung
Ronald E. Jung
Tim JodaTim Joda
Tim Joda
Aim: This systematic review and network meta‐analysis aimed to answer the PICO question: In patients undergoing immediate implant placement (IIP) [P], does Computer‐Assisted Implant Surgery (CAIS) [I] lead to higher accuracy [O] compared to free‐hand (FH) [C] implant placement? Methods: A systematic search of MEDLINE, Scopus, and Cochrane databases was conducted for randomized clinical trials (RCTs) published between January 2014 and September 2024, comparing accuracy of CAIS and FH for IIP. Two reviewers screened the studies and extracted data for a network meta‐analysis. Results: Of 2064 records screened, 7 RCTs (338 implants and 291 patients) met the inclusion criteria. These RCTs evaluated FH and dynamic, full static, and partial static CAIS for single or partial implant placement. No RCTs analyzing robotic‐assisted implant surgery (RAIS) were found. In 71.4% of the studies, IIP was performed in the anterior maxilla using a flapless approach. Accuracy was assessed by angular, cervical, and apical deviations between planned and real implant positions. All CAIS methods demonstrated significantly higher accuracy than FH ( p < 0.05), but no significant differences were observed between CAIS approaches. Conclusions: CAIS significantly improves IIP accuracy, enhancing 3D implant positioning and prosthetic outcomes. All CAIS techniques revealed comparable accuracy, allowing clinicians to select the most suitable approach for each patient. Trial Registration: PROSPERO identification number: CRD42024554241

9 April 2024 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
JPJin‐Young Park
Jin‐Young Park
FSFranz Strauss
Franz Strauss
LSLucia Schiavon
Lucia Schiavon
APAndrea Patrizi
Andrea Patrizi
JCJae‐Kook Cha
Jae‐Kook Cha
DTDaniel Thoma
Daniel Thoma
Objectives: To evaluate clinical, clinician‐ and patient‐reported outcomes (PROs) of two adjacent single posterior implants immediately loaded with definitive single crowns up to 1 year. Ten patients in need of two adjacent posterior single implants were included. All implants were placed applying a fully digital workflow. Definitive screw‐retained single zirconia crowns were delivered within 72 h after implant placement. Clinical parameters, patient‐ and clinician‐reported outcomes were assessed up to 1 year of follow‐up.Clinical Considerations: Clinical outcomes remained stable, with no implant failures or technical and biological complications throughout the observation period. Patient satisfaction was very high at baseline (crown delivery) and remained consistently high at 6 and 12 months of follow‐up. Crown insertion 3 days after implant placement was rated as an easy procedure by clinicians.Conclusions: Two adjacent single implants with immediate definitive restorations (<72 h) in the posterior region appear to be a viable and easy treatment option to shorten the overall treatment time and potentially enhancing patient satisfaction. However, randomized controlled trials are needed to confirm the advantages of this treatment protocol over a delayed loading approach.Clinical Significance: In selected cases, immediate implant loading with definitive restorations in the posterior region appears a valuable and straightforward option to shorten the overall treatment time.

4 March 2025 in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
Verified
Journal Article
Open access
PDF file
TATill Augustinowitz
Till Augustinowitz
LSLucia Schiavon
Lucia Schiavon
KMKatharina Mücke
Katharina Mücke
BSBeryl Schwarz-Herzke
Beryl Schwarz-Herzke
DDDieter Drescher
Dieter Drescher
Kathrin BeckerKathrin Becker
Kathrin Becker
Purpose: For the fabrication of an orthodontic mini-implant (OMI)-borne appliance, the position of the inserted OMI can be detected by a silicone impression or an intraoral scan (IOS). In case of digital planning, it can be taken over from the planning and the appliance can be produced in advance. This study aimed to evaluate the accuracy of these three techniques and whether there is an association with the insertion angle. Methods: Two OMIs were digitally planned and placed in the anterior palate of 11 human cadavers with different insertion angles. Subsequently, the position of each OMI was detected by an IOS, a silicone impression, and a cone-beam computed tomography (CBCT) scan, whereby the CBCT scan was set as “real position”. The measurements of accuracy were performed between the CBCT data as a reference and the preoperative digital planning, the IOS and the plaster model manufactured from the silicone impression. Results: The IOS was the most accurate in detecting the Top (mean deviation 0.14 mm) and the Apex (mean deviation 0.36 mm) of the OMIs. Significant linear deviations between the three modalities were registered for both Top ( p < 0.001) and Apex ( p = 0.010). The digital planning procedure achieved the lowest mean angular deviation of 3.7° and was significantly more accurate in this respect than the IOS ( p < 0.001). Conclusion: All methods were subject to small, but clinically irrelevant deviations. Within the limitations of a cadaver study, all methods appear to be suitable for clinical use. However, the digital workflow could be advantageous, requiring only a single visit for OMI placement and simultaneous appliance fitting.