View All Publications
5 October 2007 in Applied Optics
Verified
Journal Article
Closed access
PDF file
AAAmir Abramovich
Amir Abramovich
NKNatan Kopeika
Natan Kopeika
DRD. Rozban
D. Rozban
EFE. Farber
E. Farber
Glow discharge plasma, derived from direct-current gas breakdown, is investigated in order to realize an inexpensive terahertz (THz) room-temperature detector. Preliminary results for THz radiation show that glow discharge indicator lamps as room-temperature detectors yield good responsivity and noise-equivalent power. Development of a focal plane array (FPA) using such devices as detectors is advantageous since the cost of a glow discharge detector is approximately $0.2–$0.5 per lamp, and the FPA images will be diffraction limited. The detection mechanism of the glow discharge detector is found to be the enhanced diffusion current, which causes the glow discharge detector bias current to decrease when exposed to THz radiation.

1 May 2008 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
DRD. Rozban
D. Rozban
NKNatan Kopeika
Natan Kopeika
AAAmir Abramovich
Amir Abramovich
EFE. Farber
E. Farber
The detection mechanism of glow discharge plasma, which is derived from direct current gas breakdown, in neon indicator lamps was investigated in the terahertz and microwave regimes. Such devices exhibit high sensitivity to terahertz radiation. Experimental setups at 10, 100, and 250GHz were carried out and analyzed. The analysis of the experimental results shows that the dominant mechanism of the glow discharge detector (GDD) in these regimes is enhanced cascade ionization. Furthermore, the responsivity at 10GHz decreases with the increase in the dc bias current between the electrodes, while the responsivity at 100 and 250GHz increases with the dc current. This is attributed to electron-neutral atom collision frequency (ν) of the GDD being tens of gigahertz and its increasing with dc bias current according to dc field increase.

19 March 2001 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MAM. Arbel
M. Arbel
AAAmir Abramovich
Amir Abramovich
AEA. L. Eichenbaum
A. L. Eichenbaum
AGA. Gover
A. Gover
HKH. Kleinman
H. Kleinman
IYI. M. Yakover
I. M. Yakover
An electron beam, prebunched at the synchronous free-electron laser frequency and passing through a magnetic undulator, emits coherent (superradiant) synchrotron undulator radiation at the bunching frequency. If an external electromagnetic wave is introduced into the interaction region, at the same frequency and at a proper phase, the radiation process will be stimulated (stimulated prebunched beam radiation). We report first experimental measurements of stimulated superradiant emission in a prebunched free-electron maser. Measurements are in good agreement with theory.

21 August 2009 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AAAmir Abramovich
Amir Abramovich
NKNatan Kopeika
Natan Kopeika
DRD. Rozban
D. Rozban
The detection mechanism of glow discharge plasma in neon indicator lamps has been investigated in the terahertz and microwave spectral regions. The influence of the THz radiation polarization on the responsivity of glow discharge detectors (GDD) is considered here. There are two detection mechanisms in the GDD that exist simultaneously, each at the expense of the other. Experiments with GDD neon indicator lamps in the THz regime prove that the dominant detection mechanism of the GDD is enhanced cascade ionization rather than enhanced diffusion current. Our polarization experiments in the THz regime show that when the electric field of the THz radiation is in the same direction as the DC bias electric field of the lamp, the responsivity is about 50% higher than when the THz electric field is orthogonal to the DC field. This supports the concept that the dominant detection mechanism of the GDD in the THz regime is enhanced cascade ionization.

24 January 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DRDaniel Rozban
Daniel Rozban
ALAssaf Levanon
Assaf Levanon
HJHezi Joseph
Hezi Joseph
AAAvihai Akram
Avihai Akram
AAAmir Abramovich
Amir Abramovich
OYOrly Yadid-Pecht
Orly Yadid-Pecht
Development of focal plane arrays (FPAs) for mm wavelength and THz radiation is presented in this paper. The FPA is based upon inexpensive neon indicator lamp Glow Discharge Detectors (GDDs) that serve as pixels in the FPA. It was shown in previous investigations that inexpensive neon indicator lamp GDDs are quite sensitive to mm wavelength and THz radiation. The diameters of GDD lamps are typically 3-6 mm and thus the FPA can be diffraction limited. Development of an FPA using such devices as detectors is advantageous since the costs of such a lamp is around 30-50 cents per lamp, and it is a room temperature detector sufficiently fast for video frame rates. Recently, a new 8 × 8 GDD FPA VLSI control board was designed, constructed, and experimentally tested. First, THz images using this GDD FPA are given in this paper. By moving around the 8 × 8 pixel board appropriately in the image plane, 32 × 32 pixel images are also obtained and shown here, with much improved image quality because of much reduced pixelization distortion.

1 August 2008 in Journal of Applied Physics
Verified
Journal Article
Closed access
AAAmir Abramovich
Amir Abramovich
NKNatan Kopeika
Natan Kopeika
DRD. Rozban
D. Rozban
Development of focal plane arrays (FPAs) for millimeter wavelength and terahertz radiation is presented in this paper. FPA is based on an inexpensive glow discharge detector (GDD) that serves as a pixel in the FPA. It was shown in previous investigations [A. Abramovich et al., Appl. Opt. 46, 7207 (2007)] that those inexpensive neon indicator lamp GDDs are quite sensitive to millimeter wavelength and terahertz radiation. The diameter of the GDD lamp is 6 mm and thus the FPA can be diffraction limited. Development of a FPA using such devices as detectors is advantageous since the cost of such lamps is around $0.2–0.5 per lamp, and it also serves as a room temperature detector. Experimental results at 100 GHz show that the responsivity of the terahertz FPA 4×4 GDD pixel is three times better than in previous measurements of A. Abramovich et al. [Appl. Opt. 46, 7207 (2007)].The addition of a parabolic reflector improves the accuracy of the noise equivalent power measurement which was found to be 6×10−9 W/√Hz for a 1 kHz modulation. However, it is expected to be considerably less at higher modulation frequencies because of much reduced noise.