Michael Bacak

Dr. Michael Bacak

Paul Scherrer Institute
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2018 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
LDL. Damone
L. Damone
MBM. Barbagallo
M. Barbagallo
MMM. Mastromarco
M. Mastromarco
Alberto MengoniAlberto Mengoni
Alberto Mengoni
LCLuigi Cosentino
Luigi Cosentino
PŽP. Žugec
P. Žugec
We report on the measurement of the Be7(n,p)Li7 cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the big bang nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and they showed a large discrepancy between each other. The measurement was performed with a Si telescope and a high-purity sample produced by implantation of a Be7 ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low energy, relative to current evaluations, in the region of BBN interest, the present results are consistent with the values inferred from the time-reversal Li7(p,n)Be7 reaction, thus yielding only a relatively minor improvement on the so-called cosmological lithium problem. The relevance of these results on the near-threshold neutron production in the p+Li7 reaction is also discussed.

17 October 2019 in Physical Review C
Verified
Journal Article
Open access
PDF file
AGA Gawlik
A Gawlik
CLClaudia Lederer-Woods
Claudia Lederer-Woods
JAJ Andrzejewski
J Andrzejewski
UBU Battino
U Battino
PFP Ferreira
P Ferreira
PŽP Žugec
P Žugec
Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The (n,γ) cross section on Ge70, which is mainly produced in the s process, was measured at the neutron time-of-flight facility n_TOF at CERN. Resonance capture kernels were determined up to 40 keV neutron energy and average cross sections up to 300 keV. Stellar cross sections were calculated from kT=5 keV to kT=100 keV and are in very good agreement with a previous measurement by Walter and Beer (1985) and recent evaluations. Average cross sections are in agreement with Walter and Beer (1985) over most of the neutron energy range covered, while they are systematically smaller for neutron energies above 150 keV. We have calculated isotopic abundances produced in s-process environments in a 25 solar mass star for two initial metallicities (below solar and close to solar). While the low metallicity model reproduces best the solar system germanium isotopic abundances, the close to solar model shows a good global match to solar system abundances in the range of mass numbers A=60–80.

1 March 2019 in Physics Letters B
Verified
Journal Article
Open access
CLC. Lederer-Woods
C. Lederer-Woods
UBU. Battino
U. Battino
PFP. Ferreira
P. Ferreira
AGA. Gawlik
A. Gawlik
CGCarlos Guerrero
Carlos Guerrero
PŽP. Žugec
P. Žugec

1 February 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
PSPetr Smolyanskiy
Petr Smolyanskiy
MBMichael Bacak
Michael Bacak
BBBenedikt Ludwig Bergmann
Benedikt Ludwig Bergmann
PBPavel Broulím
Pavel Broulím
PBPetr Burian
Petr Burian
SWS.A. Wender
S.A. Wender
We characterize a novel instrument designed for radiation field decomposition and particle trajectory reconstruction for application in harsh radiation environments. The device consists of two Timepix3 assemblies with 500 µm thick silicon sensors in a face-to-face geometry. These detectors are interleaved with a set of neutron converters: 6LiF for thermal neutrons, polyethylene (PE) for fast neutrons above 1 MeV, and PE with an additional aluminum recoil proton filter for neutrons above ∼4 MeV. Application of the coincidence and anticoincidence technique together with pattern recognition allows improved separation of charged and neutral particles, their discrimination against γ-rays and assessment of the overall directionality of the fast neutron field. The instrument's charged particle tracking and separation capabilities were studied at the Danish Center for Particle Therapy (DCPT), the Proton Synchrotron, and Super Proton Synchrotron with protons (50–240 MeV), pions (1–10 GeV/c and 180 GeV/c). After developing temporal and spatial coincidence assignment methodology, we determine the relative amount of coincident detections as a function of the impact angle, present the device's impact angle resolving power (both in coincidence and anticoicidence channels). The detector response to neutrons was studied at the Czech Metrology Institute (CMI), at n_ToF and the Los Alamos Neutron Science Center (LANSCE), covering the entire spectrum from thermal up to 600 MeV. The measured tracks were assigned to their corresponding neutron energy by application of the time of flight technique. We present the achieved neutron detection efficiency as a function of neutron kinetic energy and demonstrate how the ratio of events found below the different converters can be used to assess the hardness of the neutron spectrum. As an application, we determine the neutron content within a PMMA phantom just behind the Bragg-peak during clinical irradiation condition with protons of 160 MeV.

5 June 2019 in EPJ Web of Conferences
Verified
Journal Article
Open access
PDF file
VAV. Alcayne
V. Alcayne
AKA. Kimura
A. Kimura
EME. Mendoza
E. Mendoza
DCD. Cano-Ott
D. Cano-Ott
TMT. Martínez
T. Martínez
PŽP. Žugec
P. Žugec
The neutron capture reactions of the 244Cm and 246Cm isotopes open the path for the formation of heavier Cm isotopes and heavier elements such as Bk and Cf in a nuclear reactor. In addition, both isotopes belong to the minor actinides with a large contribution to the decay heat and to the neutron emission in irradiated fuels. There are only two previous 244Cm and 246Cm capture cross section measurements: one in 1969 using a nuclear explosion [1] and the most recent data measured at J-PARC in 2010 [2]. The data for both isotopes are very scarce due to the difficulties in performing the measurements: high intrinsic activity of the samples and limited facilities capable of providing isotopically enriched samples. We have measured both neutron capture cross sections at the n_TOF Experimental Area 2 (EAR-2) with three C6 D6 detectors and also at Area 1 (EAR-1) with the TAC. Preliminary results assessing the quality and limitations (back-ground subtraction, measurement technique and counting statistics) of this new experimental datasets are presented and discussed.

9 March 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MBMatteo Busi
Matteo Busi
Marie-Christine ZdoraMarie-Christine Zdora
Marie-Christine Zdora
JVJacopo Valsecchi
Jacopo Valsecchi
MBMichael Bacak
Michael Bacak
Markus StroblMarkus Strobl
Markus Strobl
Neutron dark-field imaging is a powerful tool for the spatially resolved characterization of microstructural features of materials and components. Recently, a novel achromatic technique based on a single absorption grating for the concurrent measurement of attenuation, dark-field and differential phase contrast was introduced. However, the range of measurable length scales of the technique in quantitative dark-field measurements appeared limited to some 10–100 nanometers, due to the relatively high spatial resolution requirement to detect the projected beam modulation. Here, we show how using grating–detector distances beyond the resolution limit for a given collimation produces a sequence of inverse and regular projection patterns and, thus, leads to a significant extension of the range of accessible length scales probed by dark-field imaging. In addition, we show that this concept can also be applied to 2D grating structures, which will enable concurrent three-fold directional dark-field measurements at a wide range of length scales. The approach is demonstrated with measurements on an electrical steel sheet sample, which confirm the validity of combining the results from the regular and inverse grating patterns.