Yingying Wen

Dr. Yingying Wen

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
ZNZongliang Niu
Zongliang Niu
CYChunwei Yu
Chunwei Yu
XHXiaowen He
Xiaowen He
JZJun Zhang
Jun Zhang
YWYingying Wen
Yingying Wen

1 April 2017 in Journal of Chromatography B
Verified
Journal Article
Closed access
CNChunyan Nong
Chunyan Nong
ZNZongliang Niu
Zongliang Niu
PLPengyao Li
Pengyao Li
CWChunping Wang
Chunping Wang
WLWanyu Li
Wanyu Li
YWYingying Wen
Yingying Wen

12 November 2014 in Sensors
Verified
Journal Article
Open access
PDF file
CYChunwei Yu
Chunwei Yu
YWYingying Wen
Yingying Wen
JZJun Zhang
Jun Zhang
A new fluorescent probe P based on rhodamine for Cu2+ was synthesized and characterized. The new probe P showed high selectivity to Cu2+ over other tested metal ions. With optimal conditions, the proposed probe P worked in a wide linear range of 1.0 × 10−6–1.0 × 10−5 M with a detection limit of 3.3 × 10−7 M Cu2+ in ethanol-water solution (9:1, v:v, 20 mM HEPES, pH 7.0). Furthermore, it has been used for imaging of Cu2+ in living cells with satisfying results.

17 April 2023 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MMMengge Ma
Mengge Ma
ZNZongliang Niu
Zongliang Niu
ZTZhuhua Tang
Zhuhua Tang
JBJinyang Bai
Jinyang Bai
BLBei Li
Bei Li
YWYingying Wen
Yingying Wen

27 December 2018 in Molecules
Verified
Journal Article
Open access
PDF file
XHXiaowen He
Xiaowen He
YMYinzheng Ma
Yinzheng Ma
GYGuohui Yi
Guohui Yi
YWYingying Wen
Yingying Wen
YZYunxia Zhang
Yunxia Zhang
LZLantong Zhang
Lantong Zhang
A rapid and sensitive ionic liquid (IL) based headspace gas chromatography-mass spectrometry (HS-GC-MS) method was developed for analyzing volatile components in leaf, pericarp, and seed of Clausena lansium from different areas in Hainan Province, China. HS efficiencies were carefully investigated by using three ILs and water as matrix media. Extraction parameters, including equilibrium temperature, equilibrium time, and stirring rate had been evaluated and optimized by using an orthogonal design with OA9(33) table. Under the optimized condition of IL-based HS-GC-MS, only 100 mg of sample and 2 mL of [Bmim][BF4] were needed to comprehensively and accurately analyze the volatile components in Clausena lansium. By utilizing a cluster analysis, six clusters were obtained for ninety components. This method was simpler, more rapid, and more sensitive when compared with previously reported methods for analyzing and identifying volatile components in Clausena lansium. The results may provide a theoretical basis for further exploitation of Clausena lansium.

4 April 2019 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
ZNZongliang Niu
Zongliang Niu
JZJun Zhang
Jun Zhang
DWDongming Wu
Dongming Wu
YWYingying Wen
Yingying Wen
A novel, simple and rapid method, termed dispersive liquid–liquid microextraction with solidification of floating organic drop coupled to high performance liquid chromatography, was developed for analysis of three phenolic oestrogens including diethylstilbestrol, dienestrol and hexestrol in human urine and water samples. The parameters of dispersive liquid–liquid microextraction with solidification of floating organic drop procedure including sample pH, type and volume of disperser solvent, and type and volume of extraction solvent were optimised. High performance liquid chromatography was applied for the phenolic oestrogens’ analysis. Under the optimum extraction and detection conditions, excellent analytical performances were attained. Good linear relationships (r ≥ 0.998) between peak area and concentration for diethylstilbestrol and dienestrol were optimised from 0.1 to 20 µg/mL, for hexestrol from 2 to 50 µg/mL. Method detection limits of 28.6–666.7 ng/mL were achieved. Satisfactory relative recoveries ranging from 72% to 122% were determined for urine, lake and tap water samples, with relative standard deviations (RSDs, n = 6) of 1.5–9.8%. The developed dispersive liquid–liquid microextraction with solidification of floating organic drop-high performance liquid chromatography method has a great potential in routine residual analysis of trace phenolic oestrogens in biological and water samples.