Marta Chinnici

Dr. Marta Chinnici

Energy Technologies Department, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Energy technology and Renewable Source Department- ICT Division, Via anguillarese 302, 00123 Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2023 in Future Internet
Verified
Journal Article
Open access
PDF file
Yibrah Haile GebreyesusYibrah Haile Gebreyesus
Yibrah Haile Gebreyesus
DDDamian Dalton
Damian Dalton
SNSebastian Nixon
Sebastian Nixon
DCDavide De Chiara
Davide De Chiara
Marta ChinniciMarta Chinnici
Marta Chinnici
The need for artificial intelligence (AI) and machine learning (ML) models to optimize data center (DC) operations increases as the volume of operations management data upsurges tremendously. These strategies can assist operators in better understanding their DC operations and help them make informed decisions upfront to maintain service reliability and availability. The strategies include developing models that optimize energy efficiency, identifying inefficient resource utilization and scheduling policies, and predicting outages. In addition to model hyperparameter tuning, feature subset selection (FSS) is critical for identifying relevant features for effectively modeling DC operations to provide insight into the data, optimize model performance, and reduce computational expenses. Hence, this paper introduces the Shapley Additive exPlanation (SHAP) values method, a class of additive feature attribution values for identifying relevant features that is rarely discussed in the literature. We compared its effectiveness with several commonly used, importance-based feature selection methods. The methods were tested on real DC operations data streams obtained from the ENEA CRESCO6 cluster with 20,832 cores. To demonstrate the effectiveness of SHAP compared to other methods, we selected the top ten most important features from each method, retrained the predictive models, and evaluated their performance using the MAE, RMSE, and MPAE evaluation criteria. The results presented in this paper demonstrate that the predictive models trained using features selected with the SHAP-assisted method performed well, with a lower error and a reasonable execution time compared to other methods.

1 July 2014
Verified
Conference Paper
Closed access
GPG. Ponti
G. Ponti
Filippo PalombiFilippo Palombi
Filippo Palombi
DAD. Abate
D. Abate
FAF. Ambrosino
F. Ambrosino
GAG. Aprea
G. Aprea
AVA. Vita
A. Vita
Medium size HPC clusters play an important role in the HPC landscape in that they provide both the training environment for system scalability and a flexible production field for a large class of numerical problems. In this poster we present CRESCO4, the latest medium size HPC cluster purchased by ENEA, in operation since few months. CRESCO4 is part of a family of HPC systems, all integrated within ENEAGRID, a large infrastructure for cloud computing, which includes all the computational facilities installed at several ENEA sites in Italy.

1 January 2014 in Applied Mathematical Sciences
Verified
Journal Article
Open access
VFVincenzo Fioriti
Vincenzo Fioriti
Marta ChinniciMarta Chinnici
Marta Chinnici
JPJesus Palomo
Jesus Palomo

24 April 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Yibrah Haile GebreyesusYibrah Haile Gebreyesus
Yibrah Haile Gebreyesus
DDDamian Dalton
Damian Dalton
DCDavide De Chiara
Davide De Chiara
Marta ChinniciMarta Chinnici
Marta Chinnici
ACAndrea Chinnici
Andrea Chinnici
The application of Artificial Intelligence (AI) and Machine Learning (ML) models is increasingly leveraged to automate and optimize Data Centre (DC) operations. However, the interpretability and transparency of these complex models pose critical challenges. Hence, this paper explores the Shapley Additive exPlanations (SHAP) values model explainability method for addressing and enhancing the critical interpretability and transparency challenges of predictive maintenance models. This method computes and assigns Shapley values for each feature, then quantifies and assesses their impact on the model’s output. By quantifying the contribution of each feature, SHAP values can assist DC operators in understanding the underlying reasoning behind the model’s output in order to make proactive decisions. As DC operations are dynamically changing, we additionally investigate how SHAP can capture the temporal behaviors of feature importance in the dynamic DC environment over time. We validate our approach with selected predictive models using an actual dataset from a High-Performance Computing (HPC) DC sourced from the Enea CRESCO6 cluster in Italy. The experimental analyses are formalized using summary, waterfall, force, and dependency explanations. We delve into temporal feature importance analysis to capture the features’ impact on model output over time. The results demonstrate that model explainability can improve model transparency and facilitate collaboration between DC operators and AI systems, which can enhance the operational efficiency and reliability of DCs by providing a quantitative assessment of each feature’s impact on the model’s output.

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
Alfonso CapozzoliAlfonso Capozzoli
Alfonso Capozzoli
Gianluca SeraleGianluca Serale
Gianluca Serale
LLLucia Liuzzo
Lucia Liuzzo
Marta ChinniciMarta Chinnici
Marta Chinnici
Thermal management and air distribution performance are assuming a key role for achieving the energy saving and the IT equipment reliability for data centers (DCs). In recent years, to monitor and to control their variation several thermal performance metrics were introduced. This work presents a critical review on the most important thermal indices for DCs currently used. The main formulas and physical models on which they are based were discussed. Moreover, a critical analysis on the main advantages and drawbacks of each metric is carried out

25 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Anastasiia GrishinaAnastasiia Grishina
Anastasiia Grishina
Marta ChinniciMarta Chinnici
Marta Chinnici
Ah-Lian KorAh-Lian Kor
Ah-Lian Kor
Eric RondeauEric Rondeau
Eric Rondeau
JGJean-Philippe Georges
Jean-Philippe Georges
The energy efficiency of Data Center (DC) operations heavily relies on a DC ambient temperature as well as its IT and cooling systems performance. A reliable and efficient cooling system is necessary to produce a persistent flow of cold air to cool servers that are subjected to constantly increasing computational load due to the advent of smart cloud-based applications. Consequently, the increased demand for computing power will inadvertently increase server waste heat creation in data centers. To improve a DC thermal profile which could undeniably influence energy efficiency and reliability of IT equipment, it is imperative to explore the thermal characteristics analysis of an IT room. This work encompasses the employment of an unsupervised machine learning technique for uncovering weaknesses of a DC cooling system based on real DC monitoring thermal data. The findings of the analysis result in the identification of areas for thermal management and cooling improvement that further feeds into DC recommendations. With the aim to identify overheated zones in a DC IT room and corresponding servers, we applied analyzed thermal characteristics of the IT room. Experimental dataset includes measurements of ambient air temperature in the hot aisle of the IT room in ENEA Portici research center hosting the CRESCO6 computing cluster. We use machine learning clustering techniques to identify overheated locations and categorize computing nodes based on surrounding air temperature ranges abstracted from the data. This work employs the principles and approaches replicable for the analysis of thermal characteristics of any DC, thereby fostering transferability. This paper demonstrates how best practices and guidelines could be applied for thermal analysis and profiling of a commercial DC based on real thermal monitoring data.