Veronica Termopoli

Dr. Veronica Termopoli

University of Milano-Bicocca, Milan, Lombardy, Italy
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2019 in Chromatographia
Verified
Journal Article
Closed access
PDF file
PRPriscilla Rocío-Bautista
Priscilla Rocío-Bautista
VTVeronica Termopoli
Veronica Termopoli

1 May 2018 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MPMaurizio Piergiovanni
Maurizio Piergiovanni
ACAchille Cappiello
Achille Cappiello
Giorgio FamigliniGiorgio Famiglini
Giorgio Famiglini
VTVeronica Termopoli
Veronica Termopoli
Pierangela PalmaPierangela Palma
Pierangela Palma

19 November 2020 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Open access
PRPriscilla Rocío-Bautista
Priscilla Rocío-Bautista
Giorgio FamigliniGiorgio Famiglini
Giorgio Famiglini
VTVeronica Termopoli
Veronica Termopoli
Pierangela PalmaPierangela Palma
Pierangela Palma
ENEmir Nazdrajić
Emir Nazdrajić
Achille CappielloAchille Cappiello
Achille Cappiello
We present a modified microfluidic open interface (MOI) for the direct coupling of Bio-SPME to a liquid electron ionization-tandem mass spectrometry (LEI-MS/MS) system as a sensitive technique that can directly analyze biological samples without the need for sample cleanup or chromatographic separations as well as without measurable matrix effects (ME). We selected fentanyl as test compound. The method uses a C18 Bio-SPME fiber by direct immersion (DI) in urine and plasma and the subsequent quick desorption (1 min) in a flow-isolated volume (2.5 μL) filled with an internal standard–acetonitrile solution. The sample is then transferred to an EI source of a triple-quadrupole mass spectrometer via a LEI interface at a nanoscale flow rate. The desorption and analysis procedure requires less than 10 min. Up to 150 samples can be analyzed without observing a performance decline, with fentanyl quantitation at microgram-per-liter levels. The method workflow is extremely dependable, relatively fast, sustainable, and leads to reproducible results that enable the high-throughput screening of various biological samples.

1 September 2012 in Journal of Chromatography A
Verified
Journal Article
Closed access
Achille CappielloAchille Cappiello
Achille Cappiello
Giorgio FamigliniGiorgio Famiglini
Giorgio Famiglini
Pierangela PalmaPierangela Palma
Pierangela Palma
VTVeronica Termopoli
Veronica Termopoli
HTHelga Trufelli
Helga Trufelli

6 October 2021 in Separations
Verified
Journal Article
Open access
PDF file
VTVeronica Termopoli
Veronica Termopoli
MPMaurizio Piergiovanni
Maurizio Piergiovanni
Achille CappielloAchille Cappiello
Achille Cappiello
Pierangela PalmaPierangela Palma
Pierangela Palma
Giorgio FamigliniGiorgio Famiglini
Giorgio Famiglini
Extra virgin olive oil (EVOO) is one of the main ingredients of the Mediterranean diet. It is claimed as a functional food for its unique content of health-promoting compounds. Tyrosol (Tyr), Hydroxytyrosol (Htyr), and their phenolic derivatives present in EVOO show beneficial properties, and their identification and quantification, both in their free form and after the hydrolysis of more complex precursors, are important to certify its quality. An alternative method for quantifying free and total Tyr and Htyr in EVOO is presented using an LC–MS interface based on electron ionization (EI), called liquid electron ionization (LEI). This method requires neither sample preparation nor chromatography; the sample is diluted and injected. The selectivity and sensitivity were assessed in multiple reaction monitoring mode (MRM), obtaining confirmation and quantification in actual samples ranging from 5 to 11 mg/Kg for the free forms and from 32 to 80 mg/Kg for their total amount after hydrolysis. Two MS/MS transitions were acquired for both compounds using the Q/q ratios as confirmatory parameters. Standard addition calibration curves demonstrated optimal linearity and negligible matrix effects, allowing a correct quantification even without expensive and difficult to find labeled internal standards. After several weeks of operation, the system’s repeatability was excellent, with an intraday RSD (%) spanning from five to nine and an interday RSD (%) spanning from 9 to 11.

23 April 2018 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
FBFederica Bianchi
Federica Bianchi
Nicolo' RiboniNicolo' Riboni
Nicolo' Riboni
VTVeronica Termopoli
Veronica Termopoli
LMLucía Méndez
Lucía Méndez
IMIsabel Medina
Isabel Medina
MCMaria Careri
Maria Careri
Mass spectrometry is the most powerful technique for the detection and identification of organic compounds. It can provide molecular weight information and a wealth of structural details that give a unique fingerprint for each analyte. Due to these characteristics, mass spectrometry-based analytical methods are showing an increasing interest in the scientific community, especially in food safety, environmental, and forensic investigation areas where the simultaneous detection of targeted and nontargeted compounds represents a key factor. In addition, safety risks can be identified at the early stage through online and real-time analytical methodologies. In this context, several efforts have been made to achieve analytical instrumentation able to perform real-time analysis in the native environment of samples and to generate highly informative spectra. This review article provides a survey of some instrumental innovations and their applications with particular attention to spray-based MS methods and food analysis issues. The survey will attempt to cover the state of the art from 2012 up to 2017.