The treatment of oral squamous cell carcinoma (OSCC) is particularly complex due to its aggressive behavior, location, the patient’s age, and its spread at diagnosis. In recent years, photobiomodulation (PBM) has been introduced in different medical fields; however, its application, in patients suffering from OSCC for palliative support or to induce analgesia, has been hotly debated due to the possibility that the cell growth stimuli induced by PBM could lead to a worsening of the lesions. The aim of this study is to review the literature to observe the available data investigating the effect of PBM on cancer cells in vitro and in vivo. A review was conducted on the PubMed and Scopus databases. A total of twelve studies met the inclusion criteria and were therefore included for quality assessment and data extraction. The analysis showed that the clinical use of PBM is still only partially understood and is, therefore, controversial. Some authors stated that it could be contraindicated for clinical use in patients suffering from SCC, while others noted that it could have beneficial effects. According to the data that emerged from this review, it is possible to hypothesize that there are possibilities for PBM to play a beneficial role in treating cancer patients, but further evidence about its clinical efficacy and the identification of protocols and correct dosages is still needed.
Continuously evolving laser devices can be used in various fields; they are an alternative to the traditional cold blade surgery to perform biopsies of oral soft tissues. The aspect focused on in this paper is the possibility to use the 445 nm diode laser (Eltech K-Laser srl, Treviso, Italy) in complete safety, by evaluating its thermal effects during microscopy. A histological evaluation of the alteration of the peri-incisional edges on 10 samples was realized. All excisional biopsies were related to clinically unsuspected lesions and performed by the same expert operator. The surgical procedure was performed with the same laser parameters and the same pathologist evaluated the thermal effect on the samples. An average value of the detected tissue alteration was calculated; the average damage of the epithelium was 650.93 μm, while in the connective tissue it was 468.07 μm. In all the cases a clear diagnosis was possible, and no clinical complications were observed; so, the 445 nm diode laser proved to be a device that can be safely used for biopsies of clinically unsuspicious lesions. Due to the small number of cases, this in vivo preliminary experience needs to be extended.
Introduction: The aim of the present study was to compare the quality of the root canal obturation obtained with two different techniques, i.e., thermoplastic gutta-percha introduced through a carrier (GuttaCore) and fluid gutta-percha (GuttaFlow2). Materials and Methods: The study included 40 permanent single-rooted human teeth, divided into two groups and obturated with Guttaflow (group G) and with GuttaCore (group T). The teeth were fixed and transversely sectioned, they were examined by scanning electron microscopy. The dentin–cement–gutta–percha interface and the percentage of voids produced by the two techniques were statistically analyzed. Results: GuttaCore showed a better filling in the apical third of the canal with a percentage of voids equal to 5%. GuttaFlow showed a lower percentage of voids in the middle and coronal thirds of the canal, 1.6% of coronal voids. Statistical analysis showed a statistically significant difference in the percentage of voids in the two groups (GuttaCore and Guttaflow2) in each portion. Conclusions: GuttaFlow2 seems to flow optimally in the middle and coronal third of the canal, with greater difficulty in filling the apical third. Due to the rigidity of the carrier, GuttaCore is able to reach better the most apical portions of the canals, with greater difficulty in creating the three-dimensional seal at the level of the middle third and coronal third.
28 April 2021 in International Journal of Dentistry
Introduction. Laser-induced thermal effects can preclude a safe histological evaluation of biopsy resection margins. The aim of this study was to evaluate the suitability of a 976 nm diode laser in oral soft tissue biopsies in an ex vivo study. Materials and Methods. A 976 nm diode laser (Solase®, Lazon Medical Laser, China) has been used in the contact mode, using a 400 μm fiber tip, at different parameters from 4 to 6 W in the continuous wave (CW), with a fluence between 3184 and 4777 J/cm2, and pulsed wave (PW) mode, with a fluence between 318,4 and 477,7 J/cm2, to obtain 30 samples from fresh pig cadaver tongues. All specimens were subdivided into 6 groups (from A to F), and each group consisted of 5 samples. Two sections were obtained from each sample. A histological analysis was performed using an optical microscope at magnifications of 5x and 10x. Statistical analysis was carried out using Kruskal–Wallis and Dunn’s tests. Results. The results showed that histological readability was optimal in all the samples. The thermal damage was negligible in all groups. The average thermal damage was 208.40 ± 133.81 μm in the epithelial tissue and 330.14 ± 147.45 μm in the connective tissue. The statistical analysis showed no differences between the groups ( > 0.05). Conclusion. A 976 nm diode laser demonstrated good surgical effectiveness that provoked little peripheral damage in the cut edges and allowed a safe histological diagnosis. Clinical Relevance. In oral pathology, many times, there is fear in using the laser to remove some lesions due to its thermal effect on the tissues close to the lesion. This effect is always present in the use of the laser, but the intent is to minimize this effect to have as little alteration as possible on the surrounding tissues.
Medication-Related Osteo-Necrosis of the Jaws (MRONJ) is a severe painful complication of the long-lasting administration of bisphosphonates and anti-resorptive and anti-angiogenetic drugs in neoplastic and dysmetabolic patients, secondary to minor surgical oral interventions or chronic epithelial decubitus ulcers. Its pathogenesis is still largely unknown even if the activity change of the osteoclasts plays a relevant role in bone remodeling. The management of these patients aims to prevent the onset of the pathology or to reduce the pain and remove the necrotic bone, promoting the healing of the pathological area. Photobiomodulation therapy (PBMT), the therapeutic application of low-energy laser or LED lights, was recently introduced in the management of this condition. Thanks to its therapeutic and biomodulating action on the irradiated tissues, PBM can be used alone or in combination with antibiotic and antibacterial therapies as a preventive, antalgic or palliative tool, and in support of surgery in a combined multi-protocol that leads to a positive and better resolution and healing of the pathologic process, with great improvement of the Quality of Life (QoL) of the patients. In this narrative review, a wide analysis of the various applications of PBM in MRONJ patients’ management is analyzed, emphasizing its role as supportive care for this condition.
The surgical extraction of the lower third molar is widely practiced in oral surgery. Inflammatory complications such as pain, swelling, and trismus can cause discomfort to the patients after third molar extraction. Several methods have been used to reduce these postoperative sequelae, including the use of corticosteroids, nonsteroidal anti-inflammatory drugs, analgesics, antibiotics, less traumatic surgical methods, and the use of photobiomodulation. This narrative review summarizes the current evidence on the effect of photobiomodulation on pain, facial swelling and trismus after third molar surgery. A literature search using MEDLINE (NCBI PubMed and PMC), EMBASE, Scopus, Cochrane library, Web of Science, and Google Scholar was undertaken up to October 2021. Forty-one articles met the inclusion criteria. Photobiomodulation can be considered an alternative and useful method for controlling pain following impacted wisdom tooth surgery. The effectiveness of PBM in reducing swelling and trismus is still controversial. This review highlights the lack of consensus in the literature on protocols used in PBM therapy.