Steve Kim

Dr. Steve Kim

Performance Optimization Branch, Airman Biosciences Division, 711HPW/RH, Air Force Research Laboratory, W220, 2510 Fifth St, Area B Bldg 840, WPAFB, OH 45433,USA
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2019 in Accounts of Chemical Research
Verified
Journal Article
Closed access
MBMichael C. Brothers
Michael C. Brothers
MDMadeleine DeBrosse
Madeleine DeBrosse
CGClaude C. Grigsby
Claude C. Grigsby
RNRajesh r. Naik
Rajesh r. Naik
SHSaber M. Hussain
Saber M. Hussain
SKSteve Kim
Steve Kim

12 January 2022 in Advanced Science
Verified
Journal Article
Open access
PDF file
DSDaniel Sim
Daniel Sim
MBMichael Brothers
Michael Brothers
JSJoseph M. Slocik
Joseph M. Slocik
AIAhmad Ehteshamul Islam
Ahmad Ehteshamul Islam
BMBenji Maruyama
Benji Maruyama
SKSteve Kim
Steve Kim
Human health and performance monitoring (HHPM) is imperative to provide information necessary for protecting, sustaining, evaluating, and improving personnel in various occupational sectors, such as industry, academy, sports, recreation, and military. While various commercially wearable sensors are on the market with their capability of “quantitative assessments” on human health, physical, and psychological states, their sensing is mostly based on physical traits, and thus lacks precision in HHPM. Minimally or noninvasive biomarkers detectable from the human body, such as body fluid (e.g., sweat, tear, urine, and interstitial fluid), exhaled breath, and skin surface, can provide abundant additional information to the HHPM. Detecting these biomarkers with novel or existing sensor technologies is emerging as critical human monitoring research. This review provides a broad perspective on the state of the art biosensor technologies for HHPM, including the list of biomarkers and their physiochemical/physical characteristics, fundamental sensing principles, and high‐performance sensing transducers. Further, this paper expands to the additional scope on the key technical challenges in applying the current HHPM system to the real field.

9 May 2018 in ACS Sensors
Verified
Journal Article
Closed access
XXXingqing Xiao
Xingqing Xiao
ZKZhifeng Kuang
Zhifeng Kuang
JSJoseph M. Slocik
Joseph M. Slocik
STSirimuvva Tadepalli
Sirimuvva Tadepalli
MBMichael Brothers
Michael Brothers
RNRajesh r. Naik
Rajesh r. Naik

27 July 2012 in Soft Matter
Verified
Journal Article
Closed access
PDF file
RPRas B Pandey
Ras B Pandey
ZKZhifeng Kuang
Zhifeng Kuang
BFB. L. Farmer
B. L. Farmer
SKSteve Kim
Steve Kim
RNRajesh R. Naik
Rajesh R. Naik
Peptide binding to a graphene sheet is studied by a coarse-grained approach. All-atom molecular dynamics (MD) is used to assess the adsorption energy (e.g. binding) of each amino acid with graphene. The relative adsorption energy of each residue is normalized to describe its coarse-grained interactions with graphene which is used as an input to a phenomenological interaction in an all-residue coarse-grained (ARCG) representation of the peptide chain. Large scale Monte Carlo (MC) simulations are performed to study the stability of peptides (P1: 1H–2S–3S–4Y–5W–6Y–7A–8F–9N–10N–11K–12T and P2: 1E–2P–3L–4Q–5L–6K–7M) binding to a graphene sheet as a function of temperature. A number of local and global physical quantities are analyzed including mobility and substrate-in-contact profiles of each residue, density profiles, root mean square displacement of the center of mass of each peptide and its radius of gyration. We find that P1 has a higher probability of binding to a graphene sheet than P2 supported by both local and global physical quantities. All residues of P1 can bind to the graphene sheet at low temperatures; however, three residues 4Y–5W–6Y seem to anchor it most strongly at higher temperatures, which is consistent with an all-atom MD simulation.

16 April 2020 in Sensors
Verified
Journal Article
Open access
MBMichael Brothers
Michael Brothers
DMDavid Moore
David Moore
MLMichael St. Lawrence
Michael St. Lawrence
JHJonathan Harris
Jonathan Harris
RJRonald M. Joseph
Ronald M. Joseph
SKSteve Kim
Steve Kim
Real-time sensing of proteins, especially in wearable devices, remains a substantial challenge due to the need to convert a binding event into a measurable signal that is compatible with the chosen analytical instrumentation. Impedance spectroscopy enables real-time detection via either measuring electrostatic interactions or electron transfer reactions while simultaneously being amenable to miniaturization for integration into wearable form-factors. To create a more robust methodology for optimizing impedance-based sensors, additional fundamental studies exploring components influencing the design and implementation of these sensors are needed. This investigation addresses a sub-set of these issues by combining optical and electrochemical characterization to validate impedance-based sensor performance as a function of (1) biorecognition element density, (2) self-assembled monolayer chain length, (3) self-assembled monolayer charge density, (4) the electrochemical sensing mechanism and (5) the redox reporter selection. Using a pre-existing lysozyme aptamer and lysozyme analyte combination, we demonstrate a number of design criteria to advance the state-of-the-art in protein sensing. For this model system we demonstrated the following: First, denser self-assembled monolayers yielded substantially improved sensing results. Second, self-assembled monolayer composition, including both thickness and charge density, changed the observed peak position and peak current. Third, single frequency measurements, while less informative, can be optimized to replace multi-frequency measurements and in some cases (such as that with zwitterionic self-assembled monolayers) are preferred. Finally, various redox reporters traditionally not used in impedance sensing should be further explored. Collectively, these results can help limit bottlenecks associated with device development, enabling realization of next-generation impedance-based biosensing with customize sensor design for the specific application.

11 June 2018 in ACS Omega
Verified
Journal Article
Open access
YNYen H. Ngo
Yen H. Ngo
MBMichael Brothers
Michael Brothers
JMJennifer A. Martin
Jennifer A. Martin
CGClaude C. Grigsby
Claude C. Grigsby
KFKathy Fullerton
Kathy Fullerton
SKSteve Kim
Steve Kim
Breathing-air quality within commercial airline cabins has come under increased scrutiny because of the identification of volatile organic compounds (VOCs) from the engine bleed air used to provide oxygen to cabins. Ideally, a sensor would be placed within the bleed air pipe itself, enabling detection before it permeated through and contaminated the entire cabin. Current gas-phase sensors suffer from issues with selectivity, do not have the appropriate form factor, or are too complex for commercial deployment. Here, we chose isopropyl alcohol (IPA), a main component of de-icer spray used in the aerospace community, as a target analyte: IPA exposure has been hypothesized to be a key component of aerotoxic syndrome in pre, during, and postflight. IPAs proposed mechanism of action is that of an anesthetic and central nervous system depressant. In this work, we describe IPA sensor development by showing (1) the integration of a polymer as an IPA capture matrix, (2) the adoption of a redox chemical additives as an IPA oxidizer, and (3) the application of carbon nanotubes as an electronic sensing conduit. We demonstrate the ability to not only detect IPA at 100–10 000 ppm in unfiltered, laboratory air but also discriminate among IPA, isoprene, and acetone, especially in comparison to a typical photoionization detector. Overall, we show an electronic device that operates at room temperature and responds preferentially to IPA, where the increase in the resistance corresponds directly to the concentration of IPA. Ultimately, this study opens up the pathway to selective electronic sensors that can enable real-time monitoring in a variety of environments for the force health prevention and protection, and the potential through future work to enable low parts-per-million and possibly high parts-per-billion selective detection of gas-phase VOCs of interest.