Mariusz Hasiak

Dr. Mariusz Hasiak

Wrocław University of Science and Technology, Wrocław, Dolnośląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
MSMARIA LUISA SALADINO
MARIA LUISA SALADINO
MMMarta Markowska
Marta Markowska
CCClara Carmone
Clara Carmone
PCPatrizia Cancemi
Patrizia Cancemi
Rosa AlduinaRosa Alduina
Rosa Alduina
MWMagdalena Wawrzynska
Magdalena Wawrzynska
Sore, infected wounds are a major clinical issue, and there is thus an urgent need for novel biomaterials as multifunctional constituents for dressings. A set of biocomposites was prepared by solvent casting using different concentrations of carboxymethylcellulose (CMC) and exfoliated graphene oxide (Exf-GO) as a filler. Exf-GO was first obtained by the strong oxidation and exfoliation of graphite. The structural, morphological and mechanical properties of the composites (CMCx/Exf-GO) were evaluated, and the obtained composites were homogenous, transparent and brownish in color. The results confirmed that Exf-GO may be homogeneously dispersed in CMC. It was found that the composite has an inhibitory activity against the Gram-positive Staphylococcus aureus, but not against Gram-negative Pseudomonas aeruginosa. At the same time, it does not exhibit any cytotoxic effect on normal fibroblasts.

Verified
Journal Article
Open access
PDF file
Michał BiałyMichał Biały
Michał Biały
MHMariusz Hasiak
Mariusz Hasiak
AŁAmadeusz Łaszcz
Amadeusz Łaszcz
The continuous development of novel materials for biomedical applications is resulting in an increasingly better prognosis for patients. The application of more advanced materials relates to fewer complications and a desirable higher percentage of successful treatments. New, innovative materials being considered for biomedical applications are metallic alloys with an amorphous internal structure called metallic glasses. They are currently in a dynamic phase of development both in terms of formulating new chemical compositions and testing their properties in terms of intended biocompatibility. This review article intends to synthesize the latest research results in the field of biocompatible metallic glasses to create a more coherent picture of these materials. It summarizes and discusses the most recent findings in the areas of mechanical properties, corrosion resistance, in vitro cellular studies, antibacterial properties, and in vivo animal studies. Results are collected mainly for the most popular metallic glasses manufactured as thin films, coatings, and in bulk form. Considered materials include alloys based on zirconium and titanium, as well as new promising ones based on magnesium, tantalum, and palladium. From the properties of the examined metallic glasses, possible areas of application and further research directions to fill existing gaps are proposed.

4 January 2021 in Materials
Verified
Journal Article
Open access
PDF file
Piotr GębaraPiotr Gębara
Piotr Gębara
MHMariusz Hasiak
Mariusz Hasiak
The aim of the paper is to present a study of the magnetocaloric effect and the nature of phase transition in the Gd80Ge15Si5 (S1), Gd75Ge15Si5Ni5 (S2), Gd75Ge15Si5Pr5 (S3) and Gd75Ge15Si5Nd5 (S4) alloys. The magnetic entropy changes determined for studied samples, under external magnetic field ~3T, were 11.91, 12.11, 5.08 and 4.71 J/(kg K) for S1, S2, S3 and S4, respectively. The values of refrigerant capacity (under ~3T) were 164, 140, 160 and 140 J/kg for S1, S2, S3 and S4, respectively. The first order phase transition was detected for samples S1 and S2, while specimens S3 and S4 manifested the second order phase transition at the Curie point (TC). The analysis of temperature evolution of the exponent n (ΔSM = C·(Bmax)n) showed the validity of this method in detecting either the first or the second order phase transition and the structural transition. The analysis of critical behavior was carried out for samples S3 and S4. The critical exponents and precise TC values were calculated. The ascertained critical exponents were used to determine the theoretical value of the exponent n, which corresponded well with experimental result.

29 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
MHMariusz Hasiak
Mariusz Hasiak
BSBeata Magdalena Sobieszczańska
Beata Magdalena Sobieszczańska
AŁAmadeusz Łaszcz
Amadeusz Łaszcz
Michał BiałyMichał Biały
Michał Biały
JCJacek Chęcmanowski
Jacek Chęcmanowski
MWMagdalena Wawrzynska
Magdalena Wawrzynska
Microstructure, mechanical properties, corrosion resistance, and biocompatibility were studied for rapidly cooled 3 mm rods of Zr40Ti15Cu10Ni10Be25, Zr50Ti5Cu10Ni10Be25, and Zr40Ti15Cu10Ni5Si5Be25 (at.%) alloys, as well as for the reference 316L stainless steel and Ti-based Ti6Al4V alloy. Microstructure investigations confirm that Zr-based bulk metallic samples exhibit a glassy structure with minor fractions of crystalline phases. The nanoindentation tests carried out for all investigated composite materials allowed us to determine the mechanical parameters of individual phases observed in the samples. The instrumental hardness and elastic to total deformation energy ratio for every single phase observed in the manufactured Zr-based materials are higher than for the reference materials (316L stainless steel and Ti6Al4V alloy). A scratch tester used to determine the wear behavior of manufactured samples and reference materials revealed the effect of microstructure on mechanical parameters such as residual depth, friction force, and coefficient of friction. Electrochemical investigations in simulated body fluid performed up to 120 h show better or comparable corrosion resistance of Zr-based bulk metallic glasses in comparison with 316L stainless steel and Ti6Al4V alloy. The fibroblasts viability studies confirm the good biocompatibility of the produced materials. All obtained results show that fabricated biocompatible Zr-based materials are promising candidates for biomedical implants that require enhanced mechanical properties.

1 January 2017 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Closed access
Piotr GębaraPiotr Gębara
Piotr Gębara
Piotr PawlikPiotr Pawlik
Piotr Pawlik
MHMariusz Hasiak
Mariusz Hasiak

1 February 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
AKA. Kupczyk
A. Kupczyk
JŚJan Świerczek
Jan Świerczek
MHMariusz Hasiak
Mariusz Hasiak
Krystian PrusikKrystian Prusik
Krystian Prusik
JZJ. Zbroszczyk
J. Zbroszczyk
Piotr GębaraPiotr Gębara
Piotr Gębara