Wieland Heuer

Dr. Wieland Heuer


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2007 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
WHWieland Heuer
Wieland Heuer
CEC. Elter
C. Elter
ADA. Demling
A. Demling
ANA. Neumann
A. Neumann
SSS. Suerbaum
S. Suerbaum
MSM. Stiesch‐Scholz
M. Stiesch‐Scholz

14 June 2008
Verified
Journal Article
Closed access
CECornelius Elter
Cornelius Elter
WHWieland Heuer
Wieland Heuer
ADAnton Demling
Anton Demling
MHMatthias Hannig
Matthias Hannig
THTorsten Heidenblut
Torsten Heidenblut
MSMeike Stiesch-Scholz
Meike Stiesch-Scholz

3 May 2011 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
WHWieland Heuer
Wieland Heuer
AKAndreas Kettenring
Andreas Kettenring
SSSascha Nico Stumpp
Sascha Nico Stumpp
Joerg EberhardJoerg Eberhard
Joerg Eberhard
EGEva Gellermann
Eva Gellermann
MSMeike Stiesch
Meike Stiesch

31 March 2015 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MJMeike Luise Jakobi
Meike Luise Jakobi
NSNico Sascha Stumpp
Nico Sascha Stumpp
Meike StieschMeike Stiesch
Meike Stiesch
Joerg EberhardJoerg Eberhard
Joerg Eberhard
WHWieland Heuer
Wieland Heuer
Late implant failures, caused by the inflammation of surrounding tissues are a problem in implant dentistry. The path of bacterial transmission from teeth to implants is not completely understood. Therefore, the purpose of this study was to analyze intraindividual bacterial transmission characterizing subgingival microbiomes in teeth and implants, both in healthy subjects and in those with signs of periodontitis or peri-implantitis. Samples of peri-implant and dental sulcus fluid were collected. To identify the predominant microbiota, amplified fragments of bacterial 16S rRNA gene were separated by single strand conformation polymorphism analysis, sequenced and taxonomically classified. A total of 25 different predominant genera were found in the diseased group and 14 genera in the healthy group. Species richness did not differ significantly between implants, neighboring teeth and teeth with largest probing depth in the diseased group. Additionally, no differences between teeth and implants in the healthy group were detected. In contrast, microbial diversity varied between the different sampling points. Species richness is similar in healthy and diseased sites, but the composition of the bacterial community differed within the individual subjects. The underlying analyses strongly suggest that complete transmission from neighboring teeth to implants is unlikely.

10 April 2015 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
MDMarc Philipp Dittmer
Marc Philipp Dittmer
CHCarolina Fuchslocher Hellemann
Carolina Fuchslocher Hellemann
SGSebastian Grade
Sebastian Grade
WHWieland Heuer
Wieland Heuer
Meike StieschMeike Stiesch
Meike Stiesch
ADAnton Phillip Demling
Anton Phillip Demling
The purpose of the present study was to investigate and compare early biofilm formation on biomaterials, which are being used in contemporary fixed orthodontic treatment. This study comprised 10 healthy volunteers (5 females and 5 males) with a mean age of 27.3 +–3.7 years. Three slabs of different orthodontic materials (stainless steel, gold and ceramic) were placed in randomized order on a splint in the mandibular molar region. Splints were inserted intraorally for 48 h. Then the slabs were removed from the splints and the biofilms were stained with a two color fluorescence assay for bacterial viability (LIVE/DEAD BacLight–Bacterial Viability Kit 7012, Invitrogen, Mount Waverley, Australia). The quantitative biofilm formation was analyzed by using confocal laser scanning microscopy (CLSM). The biofilm coverage was 32.7 ± 37.7% on stainless steel surfaces, 59.5 ± 40.0% on gold surfaces and 56.8 ± 43.6% on ceramic surfaces. Statistical analysis showed significant differences in biofilm coverage between the tested materials (p=0.033). The Wilcoxon test demonstrated significantly lower biofilm coverage on steel compared to gold (p=0.011). Biofilm height on stainless steel surfaces was 4.0 ± 7.3 μm, on gold surfaces 6.0 ± 6.6 μm and on ceramic 6.5 ± 6.0 μm. The Friedman test revealed no significant differences between the tested materials (p=0.150). Pairwise comparison demonstrated significant differences between stainless steel and gold (p=0.047). Our results indicate that initial biofilm formation seemed to be less on stainless steel surfaces compared with other traditional materials in a short-term observation. Future studies should examine whether there is a difference in long-term biofilm accumulation between stainless steel, gold and ceramic brackets.

Verified
Journal Article
Open access
PDF file
AWAndreas Winkel
Andreas Winkel
WDWibke Dempwolf
Wibke Dempwolf
EGEva Gellermann
Eva Gellermann
MSMagdalena Sluszniak
Magdalena Sluszniak
SGSebastian Grade
Sebastian Grade
Meike StieschMeike Stiesch
Meike Stiesch
Peri-implant infections from bacterial biofilms on artificial surfaces are a common threat to all medical implants. They are a handicap for the patient and can lead to implant failure or even life-threatening complications. New implant surfaces have to be developed to reduce biofilm formation and to improve the long-term prognosis of medical implants. The aim of this study was (1) to develop a new method to test the antibacterial efficacy of implant surfaces by direct surface contact and (2) to elucidate whether an innovative antimicrobial copolymer coating of 4-vinyl-N-hexylpyridinium bromide and dimethyl(2-methacryloyloxyethyl) phosphonate (VP:DMMEP 30:70) on titanium is able to reduce the attachment of bacteria prevalent in peri-implant infections. With a new in vitro model with semi-coated titanium discs, we were able to show a dramatic reduction in the adhesion of various pathogenic bacteria (Streptococcus sanguinis, Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis), completely independently of effects caused by soluble materials. In contrast, soft tissue cells (human gingival or dermis fibroblasts) were less affected by the same coating, despite a moderate reduction in initial adhesion of gingival fibroblasts. These data confirm the hypothesis that VP:DMMEP 30:70 is a promising antibacterial copolymer that may be of use in several clinical applications.