Masahiro Iijima

Dr. Masahiro Iijima


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in The Angle Orthodontist
Verified
Journal Article
Closed access
NKNaohisa Kohda
Naohisa Kohda
MIMasahiro Iijima
Masahiro Iijima
TMTakeshi Muguruma
Takeshi Muguruma
WBWilliam A. Brantley
William A. Brantley
KAKaramdeep S. Ahluwalia
Karamdeep S. Ahluwalia
IMItaru Mizoguchi
Itaru Mizoguchi
Objective: To measure the forces delivered by thermoplastic appliances made from three materials and investigate effects of mechanical properties, material thickness, and amount of activation on orthodontic forces. Materials and Methods: Three thermoplastic materials, Duran (Scheu Dental), Erkodur (Erkodent Erich Kopp GmbH), and Hardcast (Scheu Dental), with two different thicknesses were selected. Values of elastic modulus and hardness were obtained from nanoindentation measurements at 28°C. A custom-fabricated system with a force sensor was employed to obtain measurements of in vitro force delivered by the thermoplastic appliances for 0.5-mm and 1.0-mm activation for bodily tooth movement. Experimental results were subjected to several statistical analyses. Results: Hardcast had significantly lower elastic modulus and hardness than Duran and Erkodur, whose properties were not significantly different. Appliances fabricated from thicker material (0.75 mm or 0.8 mm) always produced significantly greater force than those fabricated from thinner material (0.4 mm or 0.5 mm). Appliances with 1.0-mm activation produced significantly lower force than those with 0.5-mm activation, except for 0.4-mm thick Hardcast appliances. A strong correlation was found between mechanical properties of the thermoplastic materials and force produced by the appliances. Conclusions: Orthodontic forces delivered by thermoplastic appliances depend on the material, thickness, and amount of activation. Mechanical properties of the polymers obtained by nanoindentation testing are predictive of force delivery by these appliances.

1 March 2012 in The Angle Orthodontist
Verified
Journal Article
Closed access
MIMasahiro Iijima
Masahiro Iijima
TMTakeshi Muguruma
Takeshi Muguruma
WBWilliam Brantley
William Brantley
HCHan-Cheol Choe
Han-Cheol Choe
SNSusumu Nakagaki
Susumu Nakagaki
IMItaru Mizoguchi
Itaru Mizoguchi
Objective: To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires. Materials and Methods: Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n = 10). Results: Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 µm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. Conclusions: The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology.

1 January 2002 in Dental Materials
Verified
Journal Article
Closed access
MIMasahiro Iijima
Masahiro Iijima
HOH. Ohno
H. Ohno
IKI. Kawashima
I. Kawashima
KEK. Endo
K. Endo
IMI. Mizoguchi
I. Mizoguchi

18 March 2015 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
MIMasahiro Iijima
Masahiro Iijima
NKNaohisa Kohda
Naohisa Kohda
KKKyotaro Kawaguchi
Kyotaro Kawaguchi
TMTakeshi Muguruma
Takeshi Muguruma
MOMitsuru Ohta
Mitsuru Ohta
IMItaru Mizoguchi
Itaru Mizoguchi
To investigate the effects of temperature changes and stress loading on the mechanical and shape memory properties of thermoplastic materials with different glass transition behaviours and crystal structures. Five thermoplastic materials, polyethylene terephthalate glycol (Duran®, Scheu Dental), polypropylene (Hardcast®, Scheu Dental), and polyurethane (SMP MM®, SMP Technologies) with three different glass transition temperatures ( Tg ) were selected. The Tg and crystal structure were assessed using differential scanning calorimetry and X-ray diffraction. The deterioration of mechanical properties by thermal cycling and the orthodontic forces during stepwise temperature changes were investigated using nanoindentation testing and custom-made force-measuring system. The mechanical properties were also evaluated by three-point bending tests; shape recovery with heating was then investigated. The mechanical properties for each material were decreased significantly by 2500 cycles and great decrease was observed for Hardcast (crystal plastic) with higher Tg (155.5°C) and PU 1 (crystalline or semi-crystalline plastic) with lower Tg (29.6°C). The Duran, PU 2, and PU 3 with intermediate Tg (75.3°C for Duran, 56.5°C for PU 2, and 80.7°C for PU 3) showed relatively stable mechanical properties with thermal cycling. The polyurethane polymers showed perfect shape memory effect within the range of intraoral temperature changes. The orthodontic force produced by thermoplastic appliances decreased with the stepwise temperature change for all materials. Orthodontic forces delivered by thermoplastic appliances may influence by the Tg of the materials, but not the crystal structure. Polyurethane is attractive thermoplastic materials due to their unique shape memory phenomenon, but stress relaxation with temperature changes is expected.

1 January 2011 in The Angle Orthodontist
Verified
Journal Article
Closed access
TMTakeshi Muguruma
Takeshi Muguruma
MIMasahiro Iijima
Masahiro Iijima
WBWilliam A. Brantley
William A. Brantley
IMItaru Mizoguchi
Itaru Mizoguchi
Objective: To test the hypothesis that a diamond-like carbon coating does not affect the frictional properties of orthodontic wires. Materials and Methods: Two types of wires (nickel-titanium and stainless steel) were used, and diamond-like carbon (DLC) films were deposited on the wires. Three types of brackets, a conventional stainless steel bracket and two self-ligating brackets, were used for measuring static friction. DLC layers were observed by three-dimensional scanning electron microscopy (3D-SEM), and the surface roughness was measured. Hardness and elastic modulus were obtained by nanoindentation testing. Frictional forces and surface roughness were compared by the Kruskal-Wallis and Mann-Whitney U-tests. The hardness and elastic modulus of the wires were compared using Student's t-test. Results: When angulation was increased, the DLC-coated wires showed significantly less frictional force than the as-received wires, except for some wire/bracket combinations. Thin DLC layers were observed on the wire surfaces by SEM. As-received and DLC-coated wires had similar surface morphologies, and the DLC-coating process did not affect the surface roughness. The hardness of the surface layer of the DLC-coated wires was much higher than for the as-received wires. The elastic modulus of the surface layer of the DLC-coated stainless steel wire was less than that of the as-received stainless steel wire, whereas similar values were found for the nickel-titanium wires. Conclusions: The hypothesis is rejected. A DLC-coating process does reduce the frictional force.

1 July 2011 in American Journal of Orthodontics and Dentofacial Orthopedics
Verified
Journal Article
Closed access
MIMasahiro Iijima
Masahiro Iijima
TMTakeshi Muguruma
Takeshi Muguruma
WBWilliam A. Brantley
William A. Brantley
IMItaru Mizoguchi
Itaru Mizoguchi