Karolina Nowak

Dr. Karolina Nowak

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2022 in Talanta
Verified
Journal Article
Closed access
OWOlga Wachełko
Olga Wachełko
PSPaweł Szpot
Paweł Szpot
KTKaja Tusiewicz
Kaja Tusiewicz
Karolina NowakKarolina Nowak
Karolina Nowak
ACAgnieszka Chłopaś-Konowałek
Agnieszka Chłopaś-Konowałek
MZMarcin Zawadzki
Marcin Zawadzki

4 June 2019 in Forensic Toxicology
Verified
Journal Article
Open access
PDF file
MZMarcin Zawadzki
Marcin Zawadzki
Karolina NowakKarolina Nowak
Karolina Nowak
PSPaweł Szpot
Paweł Szpot
We present a fully validated method for determination of N-ethylpentylone in biological material and a case report of fatal intoxication with N-ethylpentylone.

19 January 2021 in Forensic Toxicology
Verified
Journal Article
Open access
PDF file
Karolina NowakKarolina Nowak
Karolina Nowak
PSPaweł Szpot
Paweł Szpot
MZMarcin Zawadzki
Marcin Zawadzki
Purpose: We present a case of fatal intoxication with U-47700 in combination with other NPS (N-ethylhexedrone, adinazolam, 4-chloro-N-isopropylcathinone (4-CIC), 4-chloromethcathinone (4-CMC) and sertraline) confirmed by identification and quantification in biological materials and evidences found at the scene in 2017 in Poland. Methods: Blood and urine samples were extracted with ethyl acetate from alkaline medium (pH 9); powders/crystals were diluted with methanol. The analysis was carried out using ultra-high-performance liquid chromatography–tandem mass spectrometry. Validation criteria were evaluated for blood and urine at the concentrations of 10 and 100 ng/mL. Results: The validation parameters of the method were within acceptable ranges. In the presented case, the determined concentrations of drugs were as follows, in blood: U-47700, 1470 ng/mL; N-ethylhexedrone, 58 ng/mL; adinazolam, 18 ng/mL; 4-CIC, 8.0 ng/mL; 4-CMC, 1.7 ng/mL; in urine: U-47700, 3940 ng/mL; N-ethylhexedrone, 147 ng/mL; adinazolam, 82 ng/mL; 4-CIC, 130 ng/mL; 4-CMC, 417 ng/mL. Sertraline (blood, 89 ng/mL; urine, 32 ng/mL) was also determined in both materials. The same substances were also found in 5 powders/crystals: U-47700 (12% by weight), N-ethylhexedrone (54%), adinazolam (14%), 4-CIC (23%), 4-CMC (26%). After 775 days of storage, biological samples at + 4 °C, the most stable substance was sertraline and the less, synthetic cathinones, especially 4-CIC and 4-CMC. Conclusions: The described case of fatal intoxication with NPS presented postmortem concentrations of U-47700, 4-CMC, N-ethylhexedrone, adinazolam and 4-CIC for the first time in the literature. The paper also showed stability study of these substances stored at + 4 °C for 775 days.

14 May 2020 in Journal of Forensic Sciences
Verified
Journal Article
Closed access
PDF file
Karolina NowakKarolina Nowak
Karolina Nowak
PSPaweł Szpot
Paweł Szpot
MZMarcin Zawadzki
Marcin Zawadzki

7 May 2019 in Forensic Toxicology
Verified
Journal Article
Open access
PDF file
Karolina NowakKarolina Nowak
Karolina Nowak
PSPaweł Szpot
Paweł Szpot
MZMarcin Zawadzki
Marcin Zawadzki
The authors reviewed the literature paying attention to helium suicide rates, autopsy findings in people exposed to helium, methods of collecting biological material for toxicological tests, and analytical methods used for detection and quantification of helium in the collected specimens.

19 November 2018 in Forensic Toxicology
Verified
Journal Article
Open access
PDF file
Karolina NowakKarolina Nowak
Karolina Nowak
PSPaweł Szpot
Paweł Szpot
MZMarcin Zawadzki
Marcin Zawadzki