Instant coffee is produced worldwide by spray drying coffee extract on an industrial scale. This production process is energy intensive, 70% of the operational costs are due to energy requirements. This study aims to identify the potential for energy and cost improvements by performing a conventional and advanced exergy and exergoeconomic analysis to an industrial-scale spray drying process for the production of instant coffee, using actual operational data. The study analyzed the steam generation unit, the air and coffee extract preheater, the drying section, and the final post treatment process. The performance parameters such as exergetic efficiency, exergoeconomic factor, and avoidable investment cost rate for each individual component were determined. The overall energy and exergy efficiencies of the spray drying system are 67.6% and 30.6%, respectively. The highest rate of exergy destruction is located in the boiler, which amounts to 543 kW. However, the advanced exergoeconomic analysis shows that the highest exergy destruction cost rates are located in the spray dryer and the air heat exchanger (106.9 $/h and 60.5 $/h, respectively), of which 47.7% and 3.8%, respectively, are avoidable. Accordingly, any process improvement should focus on the exergoeconomic optimization of the spray dryer.
1 December 2021 in Case Studies in Thermal Engineering
The treatment of groundwater contaminated with gasoline and diesel with H2O2, H2O2 + UV, Fenton, and photo-Fenton was studied. Fenton reactions provided the best results with 1 mM of Fe2+ and 200 mM of H2O2. High contaminant removals were achieved, in particular those of COD (Fenton: 69%, photo-Fenton: 97%), Diesel Range Organics (99.9% both reactions), Gasoline Range Organics (99.9% both reactions), Total Petroleum Hydrocarbons (Fenton: 83.8%, photo-Fenton: 92.5%), Total Phenols (Fenton: 67.3%, photo-Fenton: 90.4%), and toxicity toward Vibrio fischeri (100%, both reactions). The experiments have been performed with synthetic and real samples. The economic cost of the proposed method (14 USD/m3) is reduced by 60% with respect to that currently used in Ecuador.
Biofuels have become a source of renewable energy to offset the use of fossil fuels and meet the demand for electricity, heat, and cooling in the industrial sector. This study aims to (a) develop a simulation of a trigeneration system based on a gas turbine cycle and an absorption chiller unit, using biomass and syngas from spent coffee grounds (SCGs) to replace the conventional system currently supplying the energy requirements of an instant coffee plant located in Guayaquil, Ecuador, and (b) carry out an exergoeconomic analysis of the simulated system to compare the effects of different fuels. The results showed an increase in the exergetic efficiency from 51.9% to 84.5% when using a trigeneration system based on biomass instead of the conventional non-integrated system. Furthermore, the biomass-based system was found to have the lowest operating costs ($154.7/h) and the lowest heating, cooling, and power costs ($10.3/GJ, $20.2/GJ, and $23.4/GJ, respectively). Therefore, the results of this analysis reveal that using SCGs as biofuel in this instant coffee plant is feasible for producing steam, chilled water, and power.
1 February 2016 in Desalination and Water Treatment
Fenton and photo-Fenton processes were tested for the treatment of wastewater from a local textile industry in Ecuador. The goal of this research was to obtain an efficient, easy-to-apply method for the removal of colour, organic compounds, biodegradability, resistant pollutants, and toxicity according to the Vibrio fischeri bioluminescence test. The best results for Fenton were obtained with 100 mM H2O2 and 0.36 mM Fe2+. Toxicity was reduced by 84%, biodegradability was increased from 0.21 to 0.6, and the resulting COD and BOD5 concentrations met the Ecuadorian legislation. Both temperature and UV radiation improved Fenton degradation. Detoxification was accomplished with a combination of sand filter with Fenton.