Kim Insung

Dr. Kim Insung


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
DSDong-Jin Shin
Dong-Jin Shin
DLDong-Hwan Lim
Dong-Hwan Lim
BKBo-Kun Koo
Bo-Kun Koo
Minsoo KimMinsoo Kim
Minsoo Kim
KIKim Insung
Kim Insung
Soon-Jong JeongSoon-Jong Jeong
Soon-Jong Jeong

19 October 2017 in Journal of Electroceramics
Verified
Journal Article
Closed access
PDF file
MSMohsin Saleem
Mohsin Saleem
KIKim Insung
Kim Insung
Minsoo KimMinsoo Kim
Minsoo Kim
BKBo-Kun Koo
Bo-Kun Koo
Soon-Jong JeongSoon-Jong Jeong
Soon-Jong Jeong

26 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DSDong-Jin Shin
Dong-Jin Shin
WKWoo-Seok Kang
Woo-Seok Kang
DLDong-Hwan Lim
Dong-Hwan Lim
BKBo-Kun Koo
Bo-Kun Koo
MKMin-Soo Kim
Min-Soo Kim
KIKim Insung
Kim Insung
In this study, an acoustic emission (AE) sensor was fabricated using lead-free Ba(Zr0.2Ti0.8)O3–0.5(Ba0.7Ca0.3)TiO3 (BZT–BCT) ceramics. The acoustic and electromechanical properties of the AE sensor were determined by the shapes of the piezoelectric ceramics. To optimize the AE sensor performance, the shapes of the ceramics were designed according to various diameter/thickness ratios (D/T) = 0.5, 1.0, 1.5, 2.0, 2.5, 3.0. The BZT–BCT ceramic with D/T = 1.0 exhibited excellent values of a piezoelectric charge coefficient (d33), piezoelectric voltage coefficient (g33), and electromechanical coupling factor (kp), which were 370 (pC/N), 11.3 (10−3 Vm/N), and 0.58, respectively. Optimum values of resonant frequency (fr) = 172.724 (kHz), anti-resonant frequency (fa) = 196.067 (kHz), and effective electromechanical coupling factor (keff) = 0.473 were obtained for the manufactured BZT–BCT ceramic with D/T = 1.0. The maximum sensitivity and frequency of the AE sensor made of the BZT–BCT ceramic with a D/T ratio of 1.0 were 65 dB and 30 kHz, respectively.

23 July 2014 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
MSMohsin Saleem
Mohsin Saleem
KIKim Insung
Kim Insung
JSJ. S. Song
J. S. Song
SJS. J. Jeong
S. J. Jeong
MKM. S. Kim
M. S. Kim
SYS. Yoon
S. Yoon
BaTiO3 nanopowder was synthesized at low temperature by using an alkoxide-hydroxide sol-gel method and were sintered by microwave processing. Microwave sintering of BaTiO3was carried out at...

11 April 2016 in Sensors
Verified
Journal Article
Open access
PDF file
JLJeong Seok Lee
Jeong Seok Lee
DKDong-Goo Kang
Dong-Goo Kang
SJSeung Oh Jin
Seung Oh Jin
KIKim Insung
Kim Insung
SLSoo Yeol Lee
Soo Yeol Lee
Fast and accurate energy calibration of photon counting spectral detectors (PCSDs) is essential for their biomedical applications to identify and characterize bio-components or contrast agents in tissues. Using the x-ray tube voltage as a reference for energy calibration is known to be an efficient method, but there has been no consideration in the energy calibration of non-convergent behavior of PCSDs. We observed that a single pixel mode (SPM) CdTe PCSD based on Medipix-2 shows some non-convergent behaviors in turning off the detector elements when a high enough threshold is applied to the comparator that produces a binary photon count pulse. More specifically, the detector elements are supposed to stop producing photon count pulses once the threshold reaches a point of the highest photon energy determined by the tube voltage. However, as the x-ray exposure time increases, the threshold giving 50% of off pixels also increases without converging to a point. We established a method to take account of the non-convergent behavior in the energy calibration. With the threshold-to-photon energy mapping function established by the proposed method, we could better identify iodine component in a phantom consisting of iodine and other components.

1 January 2015 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
YBYoung Min Bae
Young Min Bae
SJSeung Oh Jin
Seung Oh Jin
KIKim Insung
Kim Insung
KSKi Young Shin
Ki Young Shin
DHDuchang Heo
Duchang Heo
DKDong-Goo Kang
Dong-Goo Kang
In the biosensing platform, label‐free detection technique provides advantages such as the short analysis time and the cost‐effectiveness. In this study, we showed the feasibility of the LSPR substrate with gold nanoparticle array for detecting low density lipoprotein (LDL) and high density lipoprotein (HDL) without labeling. The LSPR substrate was fabricated through the lift‐off process with the anodized alumina mask, and its LSPR phenomenon was observed by measuring the optical transmission of substrate. The antibodies were immobilized on the gold nanoparticle array via the chemical binding, in which the 11‐MUA was used as the linker to bind the antibodies. The binding of antibodies was confirmed by observing the shift of LSPR peak of the substrate. Finally, with the LSPR substrates with the antibodies immobilized, the detection of LDL and HDL was investigated. As a result, LDL and HDL could be detected in the clinically available concentration range, respectively.