A simple reverse phase liquid chromatographic gradient method has been developed and validated for the simultaneous determination of specified & un-specified impurities of Telmisartan and Hydrochlorothiazide in combination oral solid dosage forms. The developed method is effective to separate a total of sixteen (16) peaks and quantify eleven (11) specified impurities of Telmisartan and three (3) specified impurities of Hydrochlorothiazide with a minimum chromatographic resolution of 2.5. The separation was acquired with Inertsil ODS-3V, 150 × 4.6 mm, 3.5 μm column at a flow rate of 1.0 mL min-1 with the mobile phase-A consists of 0.02 M potassium dihydrogen phosphate (pH of 3.5) and mobile phase-B consists of a mixture of Milli-Q water and acetonitrile (100: 900 v/v) respectively. The detection of impurities was carried out at 230 nm and column temperature was maintained at 40 °C. Further optimized chromatographic conditions were applied to design of experiments to find out the critical quality attributes and established the design space. The binary combination of drug product was subjected to the different stress conditions such as acid, base, oxidation, heat and photolysis as per the recommendations of international conference on harmonization (Q2). The degradation Product found in stress patterns are well separated among main analyte compounds. The method was validated to be specific, robust and rugged in terms of change of chromatographic, instrumental and technical variables.
The current study presents a specific, accurate, simple, and rapid UPLC method for the determination of impurities present in cream and ointment formulations of betamethasone dipropionate (BMD). The analytical method was optimized using central composite design (CCD) prior to the method validation. Critical Process Parameters (CPPs) and Critical Quality Attributes (CQAs) were identified for the analytical method. A total of 17 experiments were carried out and verified the individual and interaction effects of CPPs. The CPPs were optimized using a numerical method by keeping the CQAs within the desired range (R1–R2: minimize & R3–R5: maximize) as an optimization goal. Optimized chromatographic separation was achieved using a Waters Acquity UPLC BEH C18, 100 mm × 2.1 mm, 1.7 μm column with a gradient mode of elution comprising 20 mM phosphate buffer: ACN 70 : 30, v/v as mobile phase-A and 20 mM phosphate buffer: ACN 30 : 70, v/v as mobile phase-B. The developed method was validated in accordance with ICH guidelines. The validation data conclude that the developed method is specific, accurate, linear, precise, rugged, and robust for the quantification of impurities in BMD topical formulations.