Positron emission tomography (PET) is a molecular imaging technique that provides a 3D image of functional processes in the body in vivo. Some of the radionuclides proposed for PET imaging emit high-energy positrons, which travel some distance before they annihilate (positron range), creating significant blurring in the reconstructed images. Their large positron range compromises the achievable spatial resolution of the system, which is more significant when using high-resolution scanners designed for the imaging of small animals. In this work, we trained a deep neural network named Deep-PRC to correct PET images for positron range effects. Deep-PRC was trained with modeled cases using a realistic Monte Carlo simulation tool that considers the positron energy distribution and the materials and tissues it propagates into. Quantification of the reconstructed PET images corrected with Deep-PRC showed that it was able to restore the images by up to 95% without any significant noise increase. The proposed method, which is accessible via Github, can provide an accurate positron range correction in a few seconds for a typical PET acquisition.
12 February 2021 in IEEE Transactions on Computational Imaging
Despite its success in many biomedical applications, Positron Emission Tomography (PET) has the drawback of typically having lower spatial resolution and higher noise respect to other medical imaging techniques. The best achievable spatial resolution in PET scanners is limited by factors such as the positron range, non-collinearity and the size of the detector crystals. In this work, we present a novel method that uses series of image reconstructions (super-iterations) to go beyond the expected resolution-noise limits for a given PET acquisition. The image quality improvement is achieved using the projections of the previous image reconstruction to redistribute the measured counts of each line-of-response (LOR) into several subLORs, from which a new activity distribution with better quality is reconstructed. The method was evaluated with data from the preclinical scanner 4R-SuperArgus PET/CT, using the NEMA NU4-2008 image quality phantom, a cold Derenzo phantom, and an in-vivo FDG cardiac study on a rat. Resolution and recovery coefficient (RC) improvement of ~10% was achieved while keeping the same noise level. Qualitative results from the in-vivo study also confirm this improvement in image quality. The proposed method is able to achieve significantly better images at the expense of a modest increase of the computational time, and it could be also applied to other modalities, such as SPECT and Compton Cameras.
Real-time positron emission tomography (PET) may provide information from first-shot images, enable PET-guided biopsies, and allow awake animal studies. Fully-3D iterative reconstructions yield the best images in PET, but they are too slow for real-time imaging. Analytical methods such as Fourier back projection (FBP) are very fast, but yield images of poor quality with artifacts due to noise or data incompleteness. In this work, an image reconstruction based on the pseudoinverse of the system response matrix (SRM) is presented. w. To implement the pseudoinverse method, the reconstruction problem is separated into two stages. First, the axial part of the SRM is pseudo-inverted (PINV) to rebin the 3D data into 2D datasets. Then, the resulting 2D slices can be reconstructed with analytical methods or by applying the pseudoinverse algorithm again. The proposed two-step PINV reconstruction yielded good-quality images at a rate of several frames per second, compatible with real time applications. Furthermore, extremely fast direct PINV reconstruction of projections of the 3D image collapsed along specific directions can be implemented.
PeneloPET is a Monte Carlo simulation tool for positron emission tomography based on PENELOPE. It was developed by the Nuclear Physics Group at University Complutense of Madrid and its initial version was released in 2009. In this work, we present PeneloPET v3.0, which is now available precompiled for Microsoft Windows, MacOS and Linux OS. This new release includes improved simulations of the positron range in different materials and an accurate description of the decay cascades for many radioactive nuclei including the most common non-pure positron emitters used in PET. This enables the simulation of PET acquisitions with positron-gamma emitters. This release also includes many different fully-working examples, of both clinical and preclinical scanners, as well as several numerical phantoms. Due to the simplicity of the input the output files, and the installation process, PeneloPET v3.0 can be perfectly used not only for research, but also as an educational tool in class.