The most important factors in the manufacture of shielded sheets are shielding ratio, light weight, and tensile strength. The base material should provide a light-shielding film with strong physical shock resistance, while maintaining the shielding ratio of lead. Therefore, we studied the correlation between the porosity during the mixing process and the maintenance of the shielding film characteristics. Changes in the shielding ratio can be predicted according to the properties of materials such as polymeric silicon and tungsten oxide. Further, their tensile strength and porosity may change depending on the content of the material. Experiments were carried out for each substance based on the shielding ratio with respect to the processing conditions. For a shielding film using barium sulfate (BaSO4) and polymeric silicon, increasing the porosity by the removal of air in the same manufacturing process resulted in a tensile strength of 6.4 MPa at 22% porosity. For tungsten oxide (WO3), the tensile strength was 10.5 MPa at a porosity of 12%, and for a 0.6 mm sample, the shielding performance was very similar to 0.21 mm of Pb. The porosity during the manufacturing process affected the tensile strength and shielding performance, which were significantly different for each shielding material.
Natural and medical radiation are the most frequent sources of daily low-dose radiation exposure for the general public, but these radiation levels are generally acceptable. Among various occupations, aviation crew members and medical workers are exposed to high levels of radiation from scattered rays. This study focused on developing clothing for shielding aviation crew members from natural radiation during air travel. Materials were selected considering their radiation-shielding properties. A tungsten double-layered composite yarn and a polyethylene terephthalate (PET) fiber fabric containing BaSO4 were manufactured. The characteristics and shielding performances of the products were analyzed. Prototypes of a protective scarf (for shielding the thyroid gland) and apron (for shielding the torso) for flight attendants were produced. A lightweight fabric was produced that neither restricts the movement of the wearer nor causes them skin discomfort. The shielding performances of the tungsten composite and PET fiber fabrics containing BaSO4 were 0.018 mmPb and 0.03 mmPb, respectively, demonstrating low-dose shielding that may be useful for protecting aviation crew members from scattered rays. The characteristics of the developed fibers are comparable to those of materials used in clothing production; therefore, low-dose radiation-shielding clothing could be manufactured for use in aviation, medical, and other industries.
Radiation shielding films used in medical institutions are manufactured by mixing polymer materials with eco-friendly shielding materials. However, it is not easy to distribute the shielding material particles uniformly during the process. The uniform distribution of the shielding material particles is key to the reproducibility of the shielding performance of the films. Therefore, in this study, an air pressure mirroring particle dispersion method was developed to maintain a uniform distribution of the shielding material by dispersing the shielding material on a curved reflector through an air nozzle. The particle distribution state, density, and shielding performance of the cross-section and surface of the shielding films developed using the single-sided dispersion, double-dispersion, and air pressure mirroring particle dispersion methods were evaluated. Compared to the conventional single-sided distribution method, the shielding film produced by the air pressure mirroring particle dispersion method increased the particle packing by 41.5%, density by 12.9%, shielding material content by 22.2%, and shielding performance by 21.4%. Thus, the proposed dispersion method enables better shielding performance through uniform dispersion of shielding material, which is the most important parameter in the manufacture of low-dose shielding films.
In medical institutions, radiation shielding is an effective strategy to protect medical personnel and patients from exposure. Reducing the weight of the shield worn by medical personnel in the radiation generating area plays a key role in improving their productivity and mobility. In this study, a new lightweight radiation shield was developed by electrospinning a polymer-tungsten composite material to produce nanofibers with a multi-layered thin-film structure similar to that of a morpho butterfly wing. The fabricated shield was in the form of 0.1 mm thick flexible shielding paper. The multi-layer structure of the thin shielding paper was obtained through nanofiber pattern formation via electrospinning a dispersion of tungsten particles. At 0.1 mm thickness, the paper’s shielding rate was 64.88% at 60 keV. Furthermore, at 0.3 mm thick and arranged in a laminated structure, the shielding rate was 90.10% and the lead equivalent was 0.296 mmPb. When used as an apron material, the weight can be reduced by 45% compared to existing lead products. In addition, the material is highly processable and can be used to manufacture various flexible products, such as hats, gloves, underwear, and scarves used in medical institutions.
As radiation-based techniques become an increasingly important tool for medical diagnostics, medical professionals face an increasing risk from the long-term effects of scattered radiation exposure. Although existing radiation-shielding products used in medicine are traditionally lead-based, recently, attention has turned to the development of more eco-friendly materials such as tungsten, bismuth, and barium sulfate. To date, however, the proposed alternative materials have struggled to compete with lead in terms of shielding performance and economic feasibility. This study explores the potential of radiation shielding materials based on the shells of bivalve mollusks such as oysters that are discarded from aquaculture, thereby preventing them from going to landfill. In addition, a firing process for enhancing the shielding performance of the original material is proposed. Experiments showed that shielding sheets comprising 0.3-mm-thick layers of oyster shell achieve a shielding efficiency of 37.32% for the low-energy X-rays typically encountered in medical institutions. In addition, the shielding performance was improved by increasing the density of the powdered oyster shell via plastic working at 1,200°C. This raises the possibility of developing multi-material radiation shields and highlights a new potential avenue for recycling aquacultural waste.