Most reinforced concrete (RC) frames would exhibit different degrees of damage after mainshock excitations, and these mainshock-damaged RC (MD-RC) frames are highly vulnerable to severe damage or even complete collapse under aftershock excitations. In the present study, the effectiveness of utilizing soft steel damper (SSD) as a passive energy dissipation device for seismic retrofitting of MD-RC frame under aftershock actions was investigated. A common three-story RC frame in the rural area was employed and a numerical evaluation framework of retrofitting analysis of the MD-RC frame was also proposed. Based on proposed evaluation framework, nonlinear dynamic time history analysis of the MD-RC frame with and without retrofitting schemes was conducted to evaluate the retrofit effect of the retrofitting schemes on the MD-RC frame. The results revealed that the retrofitting schemes could effectively improve the natural vibration characteristics of the MD-RC frame, especially the first-order natural frequency with a maximum increase of nearly four times. The retrofit effect of the MD-RC frame under pulse-like aftershocks is better than non-pulse-like aftershocks and the retrofit effect of minor damage MD-RC frame is slightly better than that of severe damage. In addition, only retrofitting the bottom story of MD-RC frame might cause aggravate structural damage.
14 June 2021 in International Journal of Geographical Information Science
This paper introduces a method based on centroid clustering and contour analysis to extract area and height measurements on buildings from the 3D model generated by oblique images. The method comprises three steps: (1) extract the contour plane from the fused data of the digital surface model (DSM) and digital orthophoto map (DOM); (2) identify building contour clusters based on the number of centroids contained in each category determined by mean-shift centroid clustering; (3) remove the mis-identified contours in a given building contour cluster by a contour analysis and obtain the geometric information of the building using map algebra. The proposed approach was tested against four datasets. Compared with other results, the detection has effective completeness, correctness, quality, and higher geometric accuracy. The maximum average relative error of building height and area extraction is less than 8%. The method is fast for a large-scale collection of building attributes and improves the applicability of oblique photography in GIS.