Su-tong Bridge is a cable-stayed bridge with a main span of 1088 m whose stiffness is small and it is sensitive to wind action. The length of the bridge girder at maximum single cantilever stage can reach up to 540 m, much attention should be paid in the aerodynamic performances of the under construction bridge. Based on wind tunnel tests, the aerodynamic characteristics of the girder, free standing pylon are considered. Also, field measurements of the pressure distribution on girder surface are presented. The experimental results show that only torsional vibration is found in the smooth flow at wind attack angle of 3°. Considering the influence of turbulence, the vortex-induced vibration of the girder is disappeared. The pressure coefficient values on the upper surface obtained from the wind tunnel tests are relatively larger than that obtained from field measurement. The drag coefficients values obtained from the wind tunnel tests are about 20% larger than that from field measurement. The crane can reduce the amplitude values of the free standing pylon at an incident angle of 0°, corresponding to along bridge axis. The turbulent flow can also reduce the amplitude values of vortex-induced vibration.
The vortex-induced vibration (VIV) characteristics of twin-box girders are critical in the design of long-span bridges. This study aims to investigate the VIV behavior of a twin-box girder section and to deepen the understanding of the mechanisms underlying VIV. A numerical approach that integrates both free and forced vibration analyses is developed to predict VIV performance. The VIV amplitude is evaluated using the free vibration method within the wind speed range identified by the forced vibration method. Comparisons with wind tunnel test results demonstrate the feasibility of this approach. Meanwhile, flow structure and aerodynamic characteristics of the twin-box girder were analyzed in relation to the VIV mechanism. The results show that flow restrictor plate could effectively suppress vertical VIV at a wind attack angle 0° and reduce the VIV amplitude by 50% at +3°wind attack angle. The central opening slot is identified as a significant factor in inducing VIV, as the upper and lower vortices interact with the airflow passing through the respective sections of the slot. The flow restrictor plates positioned at the upper section of the opening slot cause most upper vortices to shift downstream at wind attack angles of 0° and +3°. This shift results in minimal airflow reflux at the slot, which is crucial for optimizing VIV performance. At a wind attack angle of +3°, the vortices at the lower part of the slot persist, albeit with reduced size. These changes in vortex behavior underscore the sensitivity of vortex formation to variations in wind attack angles.
10 July 2019 in Advances in Structural Engineering
This study aims to investigate the wind protective effect of wind barriers on the Lanzhou–Xinjiang high-speed railway using wind tunnel tests. Wind barriers with different heights and porosities were analyzed. Two girders, that is, a box-girder and a trough-girder, each with 1:30 and 1:8 scales were experimentally investigated. The results suggest that the protective effect of the wind barrier with a height of 4 m and porosity of 20% is better than the others. The influence of wind barriers on the aerodynamic characteristics of train vehicles and girders must be analyzed simultaneously. The aerostatic force coefficients of trains are approximately the same at different scales, and the Reynolds number effect could be neglected.
24 July 2023 in Advances in Structural Engineering
To investigate the vortex-induced vibration (VIV) characteristics of a narrow-streamlined railway box girder and optimize its VIV performance, a long-span railway cable-stayed bridge was analyzed. Based on sectional model wind tunnel tests, the influence of the wind attack angle and the damping ratio on the VIV performance of the girder was investigated. The main inducing factors of the VIV of the narrow railway box girder were explored and a series of corresponding optimization schemes was put forward. The results show that there is no VIV when the wind attack angles are −5°, −3° and 0°, and the damping ratio is 0.2%. The non-dimensional maximum amplitudes 1000 y/ D of the girder at wind attack angles of +3° and +5° are 14.4 and 19.4, respectively. The maximum amplitudes decrease with the increase of the damping ratios. The railing base is the influence factor that induces the vertical VIV, because the separation vortices between the railing base and ballast wall, as well as behind the railings, cause the VIV of the railway steel box girder. Compared with that of the girder section with the ballastless track board, the non-dimensional maximum vertical VIV amplitude of the girder without the ballastless track board greatly increases from 19.4 to 63.5, which could effectively suppress the VIV of the main girder. Lastly, in the construction state, vertical VIV occurs for girder sections I and II, which have respective aspect ratios of 4.3 and 4.6, at wind attack angles of +3° and +5°. Girder section III, which has a 6.7 aspect ratio and is more streamlined, does not have a VIV. The greater the aspect ratio of the bridge girder, the better the VIV performance. The relevant results could serve as a guide for wind resistance design of railway streamlined box girders.
Open girder sections are vulnerable to vortex-induced vibrations (VIV) because of their bluff aerodynamic characteristics. A comparative investigation was conducted by wind tunnel tests and numerical simulation. Firstly, based on sectional model wind tunnel tests, the VIV performance of semi-open girder and separated edge-boxes open girder was studied with consideration of the influence of the equivalent mass, wind attack angle and damping ratio. The aerodynamic parameters Scruton number ( S c ) and Strouhal number ( S t ) of two girders were analyzed contrastively. In addition, VIV amplitudes corresponding to the real bridge girders were calculated by the linear and nonlinear theories. Then, flow fields around two semi-open girder sections were investigated on the basis of computational fluid dynamics. The results show that vertical and torsional VIVs of two open girders are observed, at +3°and +5° wind attack angles. There were two vertical VIV regions and the maximum amplitude in the second vertical VIV region is significantly larger than that in the first one. For the semi-open girder and separated edged-box open girder, the vertical VIV amplitudes at +5° wind attack angle is 115% and 75% larger than at +3° wind attack angle, respectively. The damping ratio could obviously mitigate the VIV of two girders and VIV amplitudes are decreased linearly with the S C number increases. There are vortexes above the girder deck at the opening position of the semi-open girder and the separated edge-boxes open girder. The oblique web and wind faring may break the large vortex into several smaller vortexes at the opening position, thus optimizing the vortex vibration performance of the girder. A thicker shear layer is formed at separated open-girder during the development of airflow towards backward of bridge deck, due to the effect of railings and the blunt boxes on the lower surface.