Xuan Thang Vu

Dr. Xuan Thang Vu

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2018 in Nature Materials
Verified
Journal Article
Closed access
PDF file
MSMartin Salinga
Martin Salinga
BKBenedikt Kersting
Benedikt Kersting
IRIder Ronneberger
Ider Ronneberger
VJVara Prasad Jonnalagadda
Vara Prasad Jonnalagadda
XVXuan Thang Vu
Xuan Thang Vu
ASAbu Sebastian
Abu Sebastian

17 February 2010 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
XVXuan Thang Vu
Xuan Thang Vu
RGR. GhoshMoulick
R. GhoshMoulick
JEJ.F. Eschermann
J.F. Eschermann
RSR. Stockmann
R. Stockmann
AOAndreas Offenhäusser
Andreas Offenhäusser
Sven IngebrandtSven Ingebrandt
Sven Ingebrandt

1 July 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
FHFelix Hempel
Felix Hempel
JLJessica Ka-Yan Law
Jessica Ka-Yan Law
TNThanh Chien Nguyen
Thanh Chien Nguyen
WMWalid Munief
Walid Munief
XLXiaoling Lu
Xiaoling Lu
Sven IngebrandtSven Ingebrandt
Sven Ingebrandt

24 August 2009 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JEJan Felix Eschermann
Jan Felix Eschermann
RSRegina Stockmann
Regina Stockmann
MHMartin Hueske
Martin Hueske
XVXuan Thang Vu
Xuan Thang Vu
Sven IngebrandtSven Ingebrandt
Sven Ingebrandt
AOAndreas Offenhäusser
Andreas Offenhäusser
Silicon nanowire (NW) transistors were fabricated in a top-down process. These devices were used to record the extracellular potential of the spontaneous activity of cardiac muscle HL-1 cells. Their signals were measured by direct dc sampling of the drain current. An improved signal-to-noise ratio compared to planar field-effect devices was observed. Furthermore the signal shape was evaluated and could be associated to different membrane currents. With these experiments, a qualitative description of the properties of the cell-NW contact was obtained and the suitability of these sensors for electrophysiological measurements in vitro was demonstrated.

4 March 2009 in Physica Status Solidi (a)
Verified
Journal Article
Closed access
PDF file
XVXuan Thang Vu
Xuan Thang Vu
JEJan Felix Eschermann
Jan Felix Eschermann
RSRegina Stockmann
Regina Stockmann
RGRanjita GhoshMoulick
Ranjita GhoshMoulick
AOAndreas Offenhäusser
Andreas Offenhäusser
Sven IngebrandtSven Ingebrandt
Sven Ingebrandt

29 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MTMarcel Tintelott
Marcel Tintelott
VPVivek Pachauri
Vivek Pachauri
Sven IngebrandtSven Ingebrandt
Sven Ingebrandt
XVXuan Thang Vu
Xuan Thang Vu
Silicon nanowire field-effect transistors (SiNW-FET) have been studied as ultra-high sensitive sensors for the detection of biomolecules, metal ions, gas molecules and as an interface for biological systems due to their remarkable electronic properties. “Bottom-up” or “top-down” approaches that are used for the fabrication of SiNW-FET sensors have their respective limitations in terms of technology development. The “bottom-up” approach allows the synthesis of silicon nanowires (SiNW) in the range from a few nm to hundreds of nm in diameter. However, it is technologically challenging to realize reproducible bottom-up devices on a large scale for clinical biosensing applications. The top-down approach involves state-of-the-art lithography and nanofabrication techniques to cast SiNW down to a few 10s of nanometers in diameter out of high-quality Silicon-on-Insulator (SOI) wafers in a controlled environment, enabling the large-scale fabrication of sensors for a myriad of applications. The possibility of their wafer-scale integration in standard semiconductor processes makes SiNW-FETs one of the most promising candidates for the next generation of biosensor platforms for applications in healthcare and medicine. Although advanced fabrication techniques are employed for fabricating SiNW, the sensor-to-sensor variation in the fabrication processes is one of the limiting factors for a large-scale production towards commercial applications. To provide a detailed overview of the technical aspects responsible for this sensor-to-sensor variation, we critically review and discuss the fundamental aspects that could lead to such a sensor-to-sensor variation, focusing on fabrication parameters and processes described in the state-of-the-art literature. Furthermore, we discuss the impact of functionalization aspects, surface modification, and system integration of the SiNW-FET biosensors on post-fabrication-induced sensor-to-sensor variations for biosensing experiments.