Maurice Mohr

Dr. Maurice Mohr

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Medicine & Science in Sports & Exercise
Verified
Journal Article
Open access
BNBenno Nigg
Benno Nigg
JVJordyn Vienneau
Jordyn Vienneau
ASAimée C. Smith
Aimée C. Smith
MTMatthieu B. Trudeau
Matthieu B. Trudeau
MMMaurice Mohr
Maurice Mohr
SNSandro R. Nigg
Sandro R. Nigg
Tions. Methods Three-dimensional ankle and knee joint kinematics were collected for 35 heel–toe runners when wearing three different running shoes and when running barefoot. Absolute mean differences in ankle and knee joint kinematics were computed between running shoe conditions. The percentage of individual runners who displayed differences below a 2°, 3°, and 5° threshold were also calculated. Results The results indicate that the mean kinematics of the ankle and knee joints were similar between running shoe conditions. Aside from ankle dorsiflexion and knee flexion, the percentage of runners maintaining their movement path between running shoes (i.e., less than 3°) was in the order of magnitude of about 80% to 100%. Many runners showed ankle and knee joint kinematics that differed between a conventional running shoe and barefoot by more than 3°, especially for ankle dorsiflexion and knee flexion. Conclusions Many runners stay in the same movement path (the preferred movement path) when running in various different footwear conditions. The percentage of runners maintaining their preferred movement path depends on the magnitude of the change introduced by the footwear condition....

29 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DDDaniel Debertin
Daniel Debertin
AWAnna Wargel
Anna Wargel
MMMaurice Mohr
Maurice Mohr
The Xsens Link motion capture suit has become a popular tool in investigating 3D running kinematics based on wearable inertial measurement units outside of the laboratory. In this study, we investigated the reliability of Xsens-based lower extremity joint angles during unconstrained running on stable (asphalt) and unstable (woodchip) surfaces within and between five different testing days in a group of 17 recreational runners (8 female, 9 male). Specifically, we determined the within-day and between-day intraclass correlation coefficients (ICCs) and minimal detectable changes (MDCs) with respect to discrete ankle, knee, and hip joint angles. When comparing runs within the same day, the investigated Xsens-based joint angles generally showed good to excellent reliability (median ICCs > 0.9). Between-day reliability was generally lower than the within-day estimates: Initial hip, knee, and ankle angles in the sagittal plane showed good reliability (median ICCs > 0.88), while ankle and hip angles in the frontal plane showed only poor to moderate reliability (median ICCs 0.38–0.83). The results were largely unaffected by the surface. In conclusion, within-day adaptations in lower-extremity running kinematics can be captured with the Xsens Link system. Our data on between-day reliability suggest caution when trying to capture longitudinal adaptations, specifically for ankle and hip joint angles in the frontal plane.

5 April 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
Felix WachholzFelix Wachholz
Felix Wachholz
FTFederico Tiribello
Federico Tiribello
MMMaurice Mohr
Maurice Mohr
SASteven van Andel
Steven van Andel
Peter FederolfPeter Federolf
Peter Federolf
A phenomenon called adolescent awkwardness is believed to alter motor control, but underlying mechanisms remain largely unclear. Since adolescents undergo neurological and anthropometrical changes during this developmental phase, we hypothesized that adolescents control their movements less tightly and use a different coordinative structure compared to adults. Moreover, we tested if emerging differences were driven by body height alterations between age groups. Using 39 reflective markers, postural movements during tandem stance with eyes open and eyes closed of 12 adolescents (height 168.1 ± 8.8 cm) and 14 adults were measured, in which 9 adults were smaller or equal than 180 cm (177.9 ± 3.0 cm) and 5 taller or equal than 190 cm (192.0 ± 2.5 cm). A principal component analysis (PCA) was used to extract the first nine principal movement components (PMk). The contribution of each PMk to the overall balancing movement was determined according to their relative variance share (rVARk) and tightness of motor control was examined using the number of times that the acceleration of each PMk changed direction (Nk). Results in rVARk did not show significant differences in coordinative structure between adolescents and adults, but Nk revealed that adolescents seem to control their movements less tightly in higher-order PMk, arguably due to slower processing times and missing automatization of postural control or potential increases in exploration. Body height was found to not cause motor control differences between age groups.

2 November 2017 in Current Issues in Sport Science (CISS)
Verified
Journal Article
Open access
BNBenno M. Nigg
Benno M. Nigg
MMMaurice Mohr
Maurice Mohr
SNSandro R. Nigg
Sandro R. Nigg

18 April 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
VTVinzenz Von Tscharner
Vinzenz Von Tscharner
MUMartin Ullrich
Martin Ullrich
MMMaurice Mohr
Maurice Mohr
DMDaniel Comaduran Marquez
Daniel Comaduran Marquez
BNBenno M Nigg
Benno M Nigg
To wavelet transform the electromyograms of the vastii muscles and generate wavelet intensity patterns (WIP) of runners. Test the hypotheses: 1) The WIP of the vastus medialis (VM) and vastus lateralis (VL) of one step are more similar than the WIPs of these two muscles, offset by one step. 2) The WIPs within one muscle differ by having maximal intensities in specific frequency bands and these intensities are not always occurring at the same time after heel strike. 3) The WIPs that were recorded form one muscle for all steps while running can be grouped into clusters with similar WIPs. It is expected that clusters might have distinctly different, cluster specific mean WIPs. The EMG of the vastii muscles from at least 1000 steps from twelve runners were recorded using a bipolar current amplifier and yielded WIPs. Based on the weights obtained after a principal component analysis the dissimilarities (1-correlation) between the WIPs were computed. The dissimilarities were submitted to a hierarchical cluster analysis to search for groups of steps with similar WIPs. The clusters formed by random surrogate WIPs were used to determine whether the groups were likely to be created in a non-random manner. The steps were grouped in clusters showing similar WIPs. The grouping was based on the frequency bands and their timing showing that they represented defining parts of the WIPs. The correlations between the WIPs of the vastii muscles that were recorded during the same step were higher than the correlations of WPIs that were recorded during consecutive steps, indicating the non-randomness of the WIPs. The spectral power of EMGs while running varies during the stance phase in time and frequency, therefore a time averaged power spectrum cannot reflect the timing of events that occur while running. It seems likely that there might be a set of predefined patterns that are used upon demand to stabilize the movement.

17 May 2018 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
MMMaurice Mohr
Maurice Mohr
TSTanja Schön
Tanja Schön
VTVinzenz von Tscharner
Vinzenz von Tscharner
BNBenno M. Nigg
Benno M. Nigg
Introduction: The vasti muscles have to work in concert to control knee joint motion during movements like walking, running, or squatting. Coherence analysis between surface electromyography (EMG) signals is a common technique to study muscle synchronization during such movements and gain insight into strategies of the central nervous system to optimize neuromuscular performance. However, different assessment methods related to EMG data acquisition, e.g., different electrode configurations or amplifier technologies, have produced inconsistent observations. Therefore, the aim of this study was to elucidate the effect of different EMG acquisition techniques (monopolar vs. bipolar electrode configuration, potential vs. current amplifier) on the magnitude, reliability, and sensitivity of intermuscular coherence between two vasti muscles during stable and unstable squatting exercises. Methods: Surface EMG signals from vastus lateralis (VL) and medialis (VM) were obtained from eighteen adults while performing series of stable und unstable bipedal squats. The EMG signals were acquired using three different recording techniques: (1) Bipolar with a potential amplifier, (2) monopolar with a potential amplifier, and (3) monopolar electrodes with a current amplifier. VL-VM coherence between the respective raw EMG signals was determined during two trials of stable squatting and one trial of unstable squatting to compare the coherence magnitude, reliability, and sensitivity between EMG recording techniques. Results: VL-VM coherence was about twice as high for monopolar recordings compared to bipolar recordings for all squatting exercises while coherence was similar between monopolar potential and current recordings. Reliability measures were comparable between recording systems while the sensitivity to an increase in intermuscular coherence during unstable vs. stable squatting was lowest for the monopolar potential system. Discussion and Conclusion: The choice of electrode configuration can have a significant effect on the magnitude of EMG-EMG coherence, which may explain previous inconsistencies in the literature. A simple simulation of cross-talk could not explain the large differences in intermuscular coherence. It is speculated that inevitable errors in the alignment of the bipolar electrodes with the muscle fiber direction leads to a reduction of information content in the differential EMG signals and subsequently to a lower resolution for the detection of intermuscular coherence.