Miguel Castilho

Miguel Castilho


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2017 in Biofabrication
Verified
Journal Article
Closed access
PDF file
ARA Ribeiro
A Ribeiro
MBM M Blokzijl
M M Blokzijl
RLR Levato
R Levato
CVC W Visser
C W Visser
Miguel CastilhoMiguel Castilho
Miguel Castilho
JMJos Malda
Jos Malda
During extrusion-based bioprinting, the deposited bioink filaments are subjected to deformations, such as collapse of overhanging filaments, which compromises the ability to stack several layers of bioink, and fusion between adjacent filaments, which compromises the resolution and maintenance of a desired pore structure. When developing new bioinks, approaches to assess their shape fidelity after printing would be beneficial to evaluate the degree of deformation of the deposited filament and to estimate how similar the final printed construct would be to the design. However, shape fidelity has been prevalently assessed qualitatively through visual inspection after printing, hampering the direct comparison of the printability of different bioinks. In this technical note, we propose a quantitative evaluation for shape fidelity of bioinks based on testing the filament collapse on overhanging structures and the filament fusion of parallel printed strands. Both tests were applied on a hydrogel platform based on poloxamer 407 and poly(ethylene glycol) blends, providing a library of hydrogels with different yield stresses. The presented approach is an easy way to assess bioink shape fidelity, applicable to any filament-based bioprinting system and able to quantitatively evaluate this aspect of printability, based on the degree of deformation of the printed filament. In addition, we built a simple theoretical model that relates filament collapse with bioink yield stress. The results of both shape fidelity tests underline the role of yield stress as one of the parameters influencing the printability of a bioink. The presented quantitative evaluation will allow for reproducible comparisons between different bioink platforms.

11 May 2018 in Biofabrication
Verified
Journal Article
Closed access
PDF file
Khoon LimKhoon Lim
Khoon Lim
RLRiccardo Levato
Riccardo Levato
Pedro CostaPedro Costa
Pedro Costa
Miguel CastilhoMiguel Castilho
Miguel Castilho
CACesar R Alcala-Orozco
Cesar R Alcala-Orozco
TWTim Woodfield
Tim Woodfield
Lithography-based three-dimensional (3D) printing technologies allow high spatial resolution that exceeds that of typical extrusion-based bioprinting approaches, allowing to better mimic the complex architecture of biological tissues. Additionally, lithographic printing via digital light processing (DLP) enables fabrication of free-form lattice and patterned structures which cannot be easily produced with other 3D printing approaches. While significant progress has been dedicated to the development of cell-laden bioinks for extrusion-based bioprinting, less attention has been directed towards the development of cyto-compatible bio-resins and their application in lithography-based biofabrication, limiting the advancement of this promising technology. In this study, we developed a new bio-resin based on methacrylated poly(vinyl alcohol) (PVA-MA), gelatin-methacryloyl (Gel-MA) and a transition metal-based visible light photoinitiator. The utilization of a visible light photo-initiating system displaying high molar absorptivity allowed the bioprinting of constructs with high resolution features, in the range of 25–50 μ m. Biofunctionalization of the resin with 1 wt% Gel-MA allowed long term survival (>90%) of encapsulated cells up to 21 d, and enabled attachment and spreading of endothelial cells seeded on the printed hydrogels. Cell-laden hydrogel constructs of high resolution with complex and ordered architecture were successfully bioprinted, where the encapsulated cells remained viable, homogenously distributed and functional. Bone and cartilage tissue synthesis was confirmed by encapsulated stem cells, underlining the potential of these DLP-bioprinted hydrogels for tissue engineering and biofabrication. Overall, the PVA-MA/Gel-MA bio-resin is a promising material for biofabrication and provides important cues for the further development of lithography-based bioprinting of complex, free-form living tissue analogues.

9 December 2019 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
YNYoung Jung No
Young Jung No
Miguel CastilhoMiguel Castilho
Miguel Castilho
YRYogambha Ramaswamy
Yogambha Ramaswamy
Hala  ZreiqatHala Zreiqat
Hala Zreiqat

13 August 2018 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
Miguel CastilhoMiguel Castilho
Miguel Castilho
AMAlain van Mil
Alain van Mil
MMMalachy Maher
Malachy Maher
CMCorina H. G. Metz
Corina H. G. Metz
GHGernot Hochleitner
Gernot Hochleitner
JMJos Malda
Jos Malda

12 July 2017 in Advanced Healthcare Materials
Verified
Journal Article
Open access
PDF file
Miguel CastilhoMiguel Castilho
Miguel Castilho
DFDries Feyen
Dries Feyen
MFMaría Flandes‐Iparraguirre
María Flandes‐Iparraguirre
GHGernot Hochleitner
Gernot Hochleitner
JGJürgen Groll
Jürgen Groll
JMJos Malda
Jos Malda
Current limitations in cardiac tissue engineering revolve around the inability to fully recapitulate the structural organization and mechanical environment of native cardiac tissue. This study aims at developing organized ultrafine fiber scaffolds with improved biocompatibility and architecture in comparison to the traditional fiber scaffolds obtained by solution electrospinning. This is achieved by combining the additive manufacturing of a hydroxyl‐functionalized polyester, (poly(hydroxymethylglycolide‐co‐ε‐caprolactone) (pHMGCL), with melt electrospinning writing (MEW). The use of pHMGCL with MEW vastly improves the cellular response to the mechanical anisotropy. Cardiac progenitor cells (CPCs) are able to align more efficiently along the preferential direction of the melt electrospun pHMGCL fiber scaffolds in comparison to electrospun poly(ε‐caprolactone)‐based scaffolds. Overall, this study describes for the first time that highly ordered microfiber (4.0–7.0 µm) scaffolds based on pHMGCL can be reproducibly generated with MEW and that these scaffolds can support and guide the growth of CPCs and thereby potentially enhance their therapeutic potential.

15 January 2014 in Biofabrication
Verified
Journal Article
Closed access
Miguel CastilhoMiguel Castilho
Miguel Castilho
CMClaus Moseke
Claus Moseke
AEAndrea Ewald
Andrea Ewald
UGUwe Gbureck
Uwe Gbureck
JGJürgen Groll
Jürgen Groll
EVElke Vorndran
Elke Vorndran
The 3D printing technique based on cement powders is an excellent method for the fabrication of individual and complex bone substitutes even in the case of large defects. The outstanding bone remodeling capacity of biphasic calcium phosphates (BCPs) containing hydroxyapatite (HA) as well as tricalcium phosphate (TCP) in varying ratios makes the adaption of powder systems resulting in BCP materials to this fabrication technique a desirable aim. This study presents the synthesis and characterization of a novel powder system for the 3D printing process, intended for the production of complexly shaped BCP scaffolds by a hydraulic setting reaction of calcium carbonate and TCP with phosphoric acid. The HA/TCP ratio in the specimens could be tailored by the calcium/phosphate ratio of the starting powder. The scaffolds could be fabricated with a dimensional accuracy of >96.5% and a minimal macro pore size of 300 µm. Independent of the phase composition the printed specimens showed a microporosity of approximately 68%, while the compressive strength strongly depended on the chemical composition and increased with rising TCP content in the scaffolds to a maximum of 1.81 MPa. Post-treatment of the scaffolds with a polylactic-co-glycolic acid-solution enhanced the mechanical properties by a factor of 8. In vitro studies showed that all BCP scaffolds were cytocompatible and enhanced the cell viability as well as the cell proliferation, as compared with pure TCP. Cell proliferation is even better on BCP when compared to HA and cell viability is in a similar range on these materials.