Erika Stracqualursi

Ms. Erika Stracqualursi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
ESErika Stracqualursi
Erika Stracqualursi
Antonello RosatoAntonello Rosato
Antonello Rosato
GLGianfranco Di Lorenzo
Gianfranco Di Lorenzo
Massimo PanellaMassimo Panella
Massimo Panella
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO

13 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
ESErika Stracqualursi
Erika Stracqualursi
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
Salvatore CelozziSalvatore Celozzi
Salvatore Celozzi
Research on corona discharge, shared by physics, chemistry and electrical engineering, has not arrested yet. As a dissipative process, the development of corona increases the resistive losses of transmission lines and enhances the line capacitance locally. Introducing additional losses and propagation delay, along the line, non-linearity and non-uniformity of the line parameters; therefore, corona should not be neglected. The present work is meant to provide the reader with comprehensive information on the corona macroscopic phenomenology and development, referring to the most relevant contributions in the literature on this subject. The models proposed in the literature for the simulation of the corona development are reviewed in detail, and sensitivity curves are provided to highlight their dependence on the input parameters.

4 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
ESErika Stracqualursi
Erika Stracqualursi
GPGiuseppe Pelliccione
Giuseppe Pelliccione
Salvatore CelozziSalvatore Celozzi
Salvatore Celozzi
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
Fast-front transients play an important role in the insulation design of any power system. When a stroke hits the shield wire or the tower of high-voltage overhead power lines, flashover may occur either along the span or across tower insulators, depending on the relevant voltages and insulation strength. As a result, backflashover may take place from the tower structure to the phase conductor whenever a huge impulse current flows along the tower towards considerably high footing impedances. For these reasons, tower modeling for transients studies is an important step in the insulation design, and also for lower voltage applications, where indirect lightning effects may play a predominant role. However, after decades of research on tower modeling, starting from the 1930s with the first model proposed by Jordan, no consensus has been reached neither on a widely accepted tower model nor on the quantitative effect of the tower models on insulation design. Moreover, the fundamental mechanisms at the base of the transient response of towers and the definition of some fundamental parameters have not been totally clarified yet. The aim of this review is to present the available tower models developed through the years in the power community, focussing mainly on lumped/distributed circuit models, and to help the reader to obtain a deeper understanding of them.

1 January 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
ESErika Stracqualursi
Erika Stracqualursi
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
JFJose Brandão Faria
Jose Brandão Faria
AAAmedeo Andreotti
Amedeo Andreotti

25 May 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
GLGiampiero Lovat
Giampiero Lovat
PBPaolo Burghignoli
Paolo Burghignoli
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
ESErika Stracqualursi
Erika Stracqualursi
Salvatore CelozziSalvatore Celozzi
Salvatore Celozzi
A recent analytical formulation for the low-frequency magnetic shielding effectiveness of a thin metal screen against a circular loop source is extended to the case of a screen exhibiting both magnetic and conductive properties. The presence of magnetic properties introduces a series impedance in the equivalent network of the structure, in addition to the shunt admittance associated with the screen conductivity. However, the fields scattered by the two elements do not interact and hence can be treated independently; furthermore, the series impedance gives rise to integrals akin to those stemming from the shunt admittance. A generalized analytical formulation for a combined magnetic and conductive screen is thus obtained, that is favorably compared with both classical approximate formulations and exact results.

8 July 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
Amedeo AndreottiAmedeo Andreotti
Amedeo Andreotti
Rodolfo ARANEORodolfo ARANEO
Rodolfo ARANEO
JFJose Brandao Faria
Jose Brandao Faria
Jinliang HeJinliang He
Jinliang He
EPEmanuel Petrache
Emanuel Petrache
ESErika Stracqualursi
Erika Stracqualursi
The ability of shield wires installed in overhead lines to mitigate lightning-induced overvoltages has been extensively investigated. Unfortunately, these studies came to different results, sometimes contradicting each other: some authors found that shield wires produce a significant overvoltage reduction, while others found the reduction negligible; conflicting results also pertain to the role played by the various parameters involved, such as the relative height of the shield wire(s) compared to the phase conductors. This paper aims to clarify this topic. The paper is organized in two parts: Part I, which starts from the analysis of the theory behind the mitigation effect, is devoted to establishing a more solid base to the topic. Two fundamental improvements are proposed. The first one is the distinction between internal and external of the parameters involved: current literature makes an indiscriminate grouping of all of them; the second one is concerned with the point along the line where the mitigation effect needs to be assessed. Thanks to this new approach, we show that this effect can be precisely quantified. The analysis in this Part I is limited to the basic case of a single grounding point of the shield wire, which represents an unrealistic case. Part II is devoted to completing the study, by applying the proposed approach to more realistic and practical cases.