The self-absorption effect seriously affects the accuracy of determination in laser-induced breakdown spectroscopy (LIBS). In this work, we proposed to reduce multielemental self-absorption within a wide spectral range (200-900 nm) by using microwave-assisted excitation in LIBS (MAE-LIBS). Self-absorption reduction of sodium (Na), potassium (K), aluminum (Al), silicon (Si), and calcium (Ca) in potassium feldspar using MAE-LIBS was investigated. The mechanisms of self-absorption reduction in MAE-LIBS were also investigated. The results show that the serious self-absorption of spectral lines (Na and K) was reduced. The full widths at half maximum (FWHMs) of Na I 589.0 nm, Na I 589.6 nm, K I 766.5 nm, and K I 769.9 nm in potassium feldspar were reduced by 43%, 43%, 53%, and 47%, respectively. MAE-LIBS also has a little FWHM reduction for spectral lines with weak self-absorption. The results demonstrate that MAE-LIBS can simultaneously reduce multielemental self-absorption.
Heavy metal pollution is one of the main problems in water pollution, which is harmful to humans. Surface-enhanced laser-induced breakdown spectroscopy (SENLIBS) has been applied to detect trace amounts of heavy metal elements in aqueous solution; however, it is still a big challenge to explore the relationship between the LIBS detection sensitivity and the substrate’s physical properties. In this work, four typical substrates, zinc (Zn), magnesium alloy (Mg), nickel (Ni), and silicon (Si), were compared; and the mechanism of spectral enhancement by different substrates in SENLIBS was investigated. The results indicated that the limit of detection (LoD) of heavy metal elements on different substrates is positively proportional to the boiling of the substrate. That is mainly because a higher plasma excitation temperature and electron density are obtained, leading to more intense collision between particles. The signal enhancement is associated with the lower boiling point of the substrate (corresponding to a lower ablation threshold and higher ablation quantity from the substrate). As a result, the best LoD was 0.0011 mg/L for chromium (Cr) and 0.004 mg/L for lead (Pb) on an optimal Zn substrate, respectively. The LoDs were sufficiently low to meet the drinking water sanitation standard. These results showed that the detection sensitivity of heavy metal elements in aqueous solution can be improved by choosing a substrate with a lower boiling point in SENLIBS.
The self-absorption effect is one of the main bottlenecks for the laser-induced breakdown spectroscopy (LIBS) technique. In this Letter, LIBS assisted by laser-stimulated absorption (LSA-LIBS) is proposed to solve this problem. The process of LSA in self-absorption reduction is discussed and confirmed. The serious self-absorption phenomena of spectral lines (K, Mn, and Al) were not observed in LSA-LIBS. The full width at half-maximum (FWHM) of K, Mn, and Al was reduced by about 58%, 25%, and 52%, respectively. The results demonstrate the capability of this approach to self-absorption reduction in the LIBS technique.
An efficient method has been developed to identify meat species by using laser-induced breakdown spectroscopy (LIBS). To improve the accuracy and stability of meat species identification, multiplicative scatter correction (MSC) was adopted to first pretreat the spectrum for correction of spectrum scatter. Then the corrected spectra were identified by using the K-nearest neighbor (KNN) model. The results showed that the identification rate improved from 94.17% to 100% and the prediction coefficient of variance (CV) decreased from 5.16% to 0.56%. This means that the accuracy and stability of meat species identification using MSC and LIBS simultaneously improved. In light of the findings, the proposed method can be a valuable tool for meat species identification using LIBS.