Loes Segerink

Prof. Loes Segerink

University of Twente, Enschede, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2019 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MHMarinke W. van der Helm
Marinke W. van der Helm
OHOlivier Y. F. Henry
Olivier Y. F. Henry
ABAmir Bein
Amir Bein
THTiama Hamkins-Indik
Tiama Hamkins-Indik
MCMichael J. Cronce
Michael J. Cronce
LSLoes Segerink
Loes Segerink
Here, we describe methods for combining impedance spectroscopy measurements with electrical simulation to reveal transepithelial barrier function and tissue structure of human intestinal epithelium cultured inside an organ-on-chip microfluidic culture device. When performing impedance spectroscopy measurements, electrical simulation enabled normalization of cell layer resistance of epithelium cultured statically in a gut-on-a-chip, which enabled determination of transepithelial electrical resistance (TEER) values that can be compared across device platforms. During culture under dynamic flow, the formation of intestinal villi was accompanied by characteristic changes in impedance spectra both measured experimentally and verified with simulation, and we demonstrate that changes in cell layer capacitance may serve as measures of villi differentiation. This method for combining impedance spectroscopy with simulation can be adapted to better monitor cell layer characteristics within any organ-on-chip in vitro and to enable direct quantitative TEER comparisons between organ-on-chip platforms which should help to advance research on organ function.

26 June 2018 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
YAYusuf B. Arık
Yusuf B. Arık
MHMarinke W. van der Helm
Marinke W. van der Helm
MOMathieu Odijk
Mathieu Odijk
LSLoes Segerink
Loes Segerink
RPRobert Passier
Robert Passier
AMAndries van der Meer
Andries van der Meer
Disruption of tissue barriers formed by cells is an integral part of the pathophysiology of many diseases. Therefore, a thorough understanding of tissue barrier function is essential when studying the causes and mechanisms of disease as well as when developing novel treatments. In vitro methods play an integral role in understanding tissue barrier function, and several techniques have been developed in order to evaluate barrier integrity of cultured cell layers, from microscopy imaging of cell-cell adhesion proteins to measuring ionic currents, to flux of water or transport of molecules across cellular barriers. Unfortunately, many of the current in vitro methods suffer from not fully recapitulating the microenvironment of tissues and organs. Recently, organ-on-chip devices have emerged to overcome this challenge. Organs-on-chips are microfluidic cell culture devices with continuously perfused microchannels inhabited by living cells. Freedom of changing the design of device architecture offers the opportunity of recapitulating the in vivo physiological environment while measuring barrier function. Assessment of barriers in organs-on-chips can be challenging as they may require dedicated setups and have smaller volumes that are more sensitive to environmental conditions. But they do provide the option of continuous, non-invasive sensing of barrier quality, which enables better investigation of important aspects of pathophysiology, biological processes, and development of therapies that target barrier tissues. Here, we discuss several techniques to assess barrier function of tissues in organs-on-chips, highlighting advantages and technical challenges.

27 July 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MZMariia Zakharova
Mariia Zakharova
MCMarciano Palma Do Carmo
Marciano Palma Do Carmo
MHMarinke van der Helm
Marinke van der Helm
HLHai Le-The
Hai Le-The
MGMees Graaf
Mees Graaf
LSLoes Segerink
Loes Segerink
The developed multiplexed chip contains 8 channels that can be accessed individually or simultaneously with increased throughput. The visual inspection of cells in the device was improved with our fabricated 2 μm-thick porous PDMS membrane.

4 February 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LSLoes Segerink
Loes Segerink
ASAd J. Sprenkels
Ad J. Sprenkels
PBPaul M. ter Braak
Paul M. ter Braak
IVIstvan Vermes
Istvan Vermes
ABAlbert van Den Berg
Albert van Den Berg
In this article we describe the development of a microfluidic chip to determine the concentration of spermatozoa in semen, which is a main quality parameter for the fertility of a man. A microfluidic glass-glass chip is used, consisting of a microchannel with a planar electrode pair that allows the detection of spermatozoa passing the electrodes using electrical impedance measurements. Cells other than spermatozoa in semen also cause a change in impedance when passing the electrodes, interfering with the spermatozoa count. We demonstrate that the change in electrical impedance is related to the size of cells passing the electrodes, allowing to distinguish between spermatozoa and HL-60 cells suspended in washing medium. In the same way we are able to distinguish between polystyrene beads and spermatozoa. Thus, by adding a known concentration of polystyrene beads to a boar semen sample, the spermatozoa concentrations of seven mixtures are measured and show a good correlation with the actual concentration (R2-value = 0.97). To our knowledge this is the first time that the concentration of spermatozoa has been determined on chip using electrical impedance measurements without a need to know the actual flow speed. The proposed method to determine the concentration can be easily applied to other cells. The described on-chip determination of the spermatozoa concentration is a first step towards a microfluidic system for a complete quality analysis of semen.

15 March 2016 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
BWB. de Wagenaar
B. de Wagenaar
SDS. Dekker
S. Dekker
HBH. L. de Boer
H. L. de Boer
JBJ. G. Bomer
J. G. Bomer
WOW. Olthuis
W. Olthuis
LSLoes Segerink
Loes Segerink
The use of high quality semen for artificial insemination in the livestock industry is essential for successful outcome.

16 April 2018 in Nanoscale
Verified
Journal Article
Open access
PDF file
HLHai Le-The
Hai Le-The
MTMartijn Tibbe
Martijn Tibbe
JLJoshua Loessberg-Zahl
Joshua Loessberg-Zahl
MCMarciano Palma Do Carmo
Marciano Palma Do Carmo
MHMarinke van der Helm
Marinke van der Helm
JEJan Eijkel
Jan Eijkel
Free-standing polydimethylsiloxane (PDMS) through-hole membranes have been studied extensively in recent years for chemical and biomedical applications. However, robust fabrication of such membranes with sub-μm through-holes, and at a sub-μm thickness over large areas is challenging. In this paper, we report a robust and simple method for large-scale fabrication of free-standing and sub-μm PDMS through-hole membranes, combining soft-lithography with reactive plasma etching techniques. First, arrays of sub-μm photoresist (PR) columns were patterned on another spin-coated sacrificial PR layer, using conventional photolithography processes. Subsequently, a solution of PDMS : hexane at a 1 : 10 ratio was spin-coated over these fabricated arrays. The cured PDMS membrane was etched in a plasma mixture of sulfur hexafluoride (SF6) and oxygen (O2) to open the through-holes. This PDMS membrane can be smoothly released with a supporting ring by completely dissolving the sacrificial PR structures in acetone. Using this fabrication method, we demonstrated the fabrication of free-standing PDMS membranes at various sub-μm thicknesses down to 600 ± 20 nm, and nanometer-sized through-hole (810 ± 20 nm diameter) densities, over areas as large as 3 cm in diameter. Furthermore, we demonstrated the potential of the as-prepared membranes as cell-culture substrates for biomedical applications by culturing endothelial cells on these membranes in a Transwell-like set-up.