Kyoung Lee

Dr. Kyoung Lee

Center for Nano Bio Development, National Nanofab Center, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2019 in Nano Convergence
Verified
Journal Article
Open access
PDF file
HPHong Jun Park
Hong Jun Park
JYJo Hee Yoon
Jo Hee Yoon
Kyoung LeeKyoung Lee
Kyoung Lee
BCBong Gill Choi
Bong Gill Choi
We report potentiometric performance of a polyaniline nanofiber array-based pH sensor fabricated by combining a dilute chemical polymerization and low-cost and simple screen printing process. The pH sensor had a two-electrode configuration consisting of polyaniline nanofiber array sensing electrode and Ag/AgCl reference electrode. Measurement of electromotive force between sensing and reference electrodes provided various electrochemical properties of pH sensors. The pH sensor show excellent sensor performances of sensitivity of 62.4 mV/pH, repeatability of 97.9% retention, response time of 12.8 s, and durability of 3.0 mV/h. The pH sensor could also measure pH changes as the milk is spoiled, which is similar to those of a commercial pH meter. The pH sensors were highly flexible, and thus can measure the fruit decay on the curved surface of an apple. This flexible and miniature pH sensor opens new opportunities for monitoring of water, product process, human health, and chemical (or bio) reactions even using small volumes of samples.

1 March 2017 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
JYJo Hee Yoon
Jo Hee Yoon
SHSeok Bok Hong
Seok Bok Hong
SYSeok-Oh Yun
Seok-Oh Yun
SLSeok Jae Lee
Seok Jae Lee
TLTae Jae Lee
Tae Jae Lee
BCBong Gill Choi
Bong Gill Choi

8 March 2021 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
DKDong Seok Kim
Dong Seok Kim
JJJae-Min Jeong
Jae-Min Jeong
HPHong Jun Park
Hong Jun Park
YKYeong Kyun Kim
Yeong Kyun Kim
Kyoung LeeKyoung Lee
Kyoung Lee
BCBong Gill Choi
Bong Gill Choi
Highlights: Ultrathin and defect-free graphene ink is prepared through a high-throughput fluid dynamics process, resulting in a high exfoliation yield (53.5%) and a high concentration (47.5 mg mL−1). A screen-printed graphene conductor exhibits a high electrical conductivity of 1.49 × 104 S m−1 and good mechanical flexibility. An electrochemical sodium ion sensor based on graphene ink exhibits an excellent potentiometric sensing performance in a mechanically bent state. Real-time monitoring of sodium ion concentration in sweat is demonstrated. Conductive inks based on graphene materials have received significant attention for the fabrication of a wide range of printed and flexible devices. However, the application of graphene fillers is limited by their restricted mass production and the low concentration of their suspensions. In this study, a highly concentrated and conductive ink based on defect-free graphene was developed by a scalable fluid dynamics process. A high shear exfoliation and mixing process enabled the production of graphene at a high concentration of 47.5 mg mL−1 for graphene ink. The screen-printed graphene conductor exhibits a high electrical conductivity of 1.49 × 104 S m−1 and maintains high conductivity under mechanical bending, compressing, and fatigue tests. Based on the as-prepared graphene ink, a printed electrochemical sodium ion (Na+) sensor that shows high potentiometric sensing performance was fabricated. Further, by integrating a wireless electronic module, a prototype Na+-sensing watch is demonstrated for the real-time monitoring of the sodium ion concentration in human sweat during the indoor exercise of a volunteer. The scalable and efficient procedure for the preparation of graphene ink presented in this work is very promising for the low-cost, reproducible, and large-scale printing of flexible and wearable electronic devices.

1 December 2016 in Journal of Colloid and Interface Science
Verified
Journal Article
Closed access
KKKyung Hoon Kim
Kyung Hoon Kim
JJJae-Min Jeong
Jae-Min Jeong
SLSeok Jae Lee
Seok Jae Lee
BCBong Gill Choi
Bong Gill Choi
Kyoung LeeKyoung Lee
Kyoung Lee

5 December 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
HJHyowon Jang
Hyowon Jang
JSJayeon Song
Jayeon Song
SKSunjoo Kim
Sunjoo Kim
JBJung-Hyun Byun
Jung-Hyun Byun
Kyoung LeeKyoung Lee
Kyoung Lee
TKTaejoon Kang
Taejoon Kang
Endonucleases have recently widely used in molecular diagnostics. Here, we report a strategy to exploit the properties of Argonaute (Ago) proteins for molecular diagnostics by introducing an artificial nucleic acid circuit with Ago protein (ANCA) method. The ANCA is designed to perform a continuous autocatalytic reaction through cross-catalytic cleavage of the Ago protein, enabling one-step, amplification-free, and isothermal DNA detection. Using the ANCA method, carbapenemase-producing Klebsiella pneumoniae (CPKP) are successfully detected without DNA extraction and amplification steps. In addition, we demonstrate the detection of carbapenem-resistant bacteria in human urine and blood samples using the method. We also demonstrate the direct identification of CPKP swabbed from surfaces using the ANCA method in conjunction with a three-dimensional nanopillar structure. Finally, the ANCA method is applied to detect CPKP in rectal swab specimens from infected patients, achieving sensitivity and specificity of 100% and 100%, respectively. The developed method can contribute to simple, rapid and accurate diagnosis of CPKP, which can help prevent nosocomial infections.

15 December 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MYMinHo Yang
MinHo Yang
SJSoon Woo Jeong
Soon Woo Jeong
SCSung Jin Chang
Sung Jin Chang
KKKyung Hoon Kim
Kyung Hoon Kim
MJMinjeong Jang
Minjeong Jang
Kyoung LeeKyoung Lee
Kyoung Lee