Yi Zhang

Yi Zhang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2022 in ACS Omega
Verified
Journal Article
Open access
LYLiangtao Yang
Liangtao Yang
LGLu Gan
Lu Gan
ZZZhenggang Zhang
Zhenggang Zhang
ZZZhilin Zhang
Zhilin Zhang
Hui YangHui Yang
Hui Yang
JWJinglong Wu
Jinglong Wu
To obtain a performance improved dry electrode for bioelectrical activity detection is still a challenge, which is mainly due to the poor fundamental understanding on the impedance of the electrode–skin interface. Herein, the impedance between the electrode and the skin interface of three types of electrodes, which are the wet electrode, semidry electrode, and dry electrode, is investigated with electrochemical impedance spectroscopy combined with the spectra fitting technique. The parameters of performance duration, potential, and frequency associated with the impedance are explored for these three types of electrodes. The overall impedance is roughly constant within the performance duration and the potential applied in this study. Along with the frequency decreases, the impedance of the dry electrode reduces faster and is more complicated compared with the other two types of electrodes. Moreover, the results computed with the equivalent circuits show that the charge transfer resistance is additionally present compared to the wet and semidry electrodes. This large and additional charge transfer resistance may explain its relatively poorer electrophysiological properties.

1 October 2021 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PDF file
LYLiangtao Yang
Liangtao Yang
QLQing Liu
Qing Liu
ZZZhilin Zhang
Zhilin Zhang
LGLu Gan
Lu Gan
YZYi Zhang
Yi Zhang
JWJinglong Wu
Jinglong Wu

6 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
QLQing Liu
Qing Liu
LYLiangtao Yang
Liangtao Yang
ZZZhilin Zhang
Zhilin Zhang
Hui YangHui Yang
Hui Yang
YZYi Zhang
Yi Zhang
JWJinglong Wu
Jinglong Wu
Recently, advanced electrodes have been developed, such as semi-dry, dry contact, dry non-contact, and microneedle array electrodes. They can overcome the issues of wet electrodes and maintain high signal quality. However, the variations in these electrodes are still unclear and not explained, and there is still confusion regarding the feasibility of electrodes for different application scenarios. In this review, the physical features and electroencephalogram (EEG) signal performances of these advanced EEG electrodes are introduced in view of the differences in contact between the skin and electrodes. Specifically, contact features, biofeatures, impedance, signal quality, and artifacts are discussed. The application scenarios and prospects of different types of EEG electrodes are also elucidated.

26 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Lin ZengLin Zeng
Lin Zeng
CXChen Xi
Chen Xi
RZRongrong Zhang
Rongrong Zhang
SHShi Hu
Shi Hu
Hongpeng ZhangHongpeng Zhang
Hongpeng Zhang
Hui YangHui Yang
Hui Yang
The separation and purification of a sample of interest is essential for subsequent detection and analysis procedures, but there is a lack of effective separation methods with which to purify nano-sized particles from the sample media. In this paper, a microfluidic system based on negative magnetophoresis is presented for the high-resolution separation of nanoparticles. The system includes on-chip magnetic pole arrays and permalloys that symmetrically distribute on both sides of the separation channel and four permanent magnets that provide strong magnetic fields. The microfluidic system can separate 200 nm particles with a high purity from the mixture (1000 nm and 200 nm particles) due to a magnetic field gradient as high as 10,000 T/m being generated inside the separation channel, which can provide a negative magnetophoretic force of up to 10 pN to the 1000 nm particle. The overall recovery rate of the particles reaches 99%, the recovery rate of 200 nm particles is 84.2%, and the purity reaches 98.2%. Compared with the existing negative magnetophoretic separation methods, our system not only exhibits high resolution on particle sizes (800 nm), but also improves the sample processing throughput, which reaches 2.5 μL/min. The microfluidic system is expected to provide a new solution for the high-purity separation of nanoparticles, as well as nanobiological samples.

22 May 2023 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
QLQing Liu
Qing Liu
JZJie Zhou
Jie Zhou
LYLiangtao Yang
Liangtao Yang
JXJiajia Xie
Jiajia Xie
CGChenhui Guo
Chenhui Guo
YZYi Zhang
Yi Zhang
PPEM gel-free electrode for continuous noninvasive electrophysiological signal monitoring.

12 November 2024 in Journal of Materials Chemistry B
Verified
Journal Article
Open access
PDF file
ZXZhengchen Xiang
Zhengchen Xiang
LYLiangtao Yang
Liangtao Yang
BYBin Yu
Bin Yu
QZQi Zeng
Qi Zeng
THTao Huang
Tao Huang
MZMeifang Zhu
Meifang Zhu
This review evaluated electrocorticography (ECoG) electrode performance based on key properties and improvements from polymers, categorizing them as sensitive or structural, while discussing preparation methods, challenges, and future perspectives.