Michael Brennan

Prof. Michael Brennan


Research Focus & Metrics

Academic Career Length

45Years (1982-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2016 in Journal of Applied Mechanics
Verified
Journal Article
Closed access
PDF file
Ze-Qi LuZe-Qi Lu
Ze-Qi Lu
TYTiejun Yang
Tiejun Yang
MBMichael Brennan
Michael Brennan
ZLZhigang Liu
Zhigang Liu
LCLi-Qun Chen
Li-Qun Chen

19 September 2019 in Applied Mechanics Reviews
Verified
Journal Article
Closed access
PDF file
DLDiego Ledezma-Ramirez
Diego Ledezma-Ramirez
PTPablo Ernesto Tapia-González
Pablo Ernesto Tapia-González
NFNeil Ferguson
Neil Ferguson
MBMichael Brennan
Michael Brennan
BTBin Tang
Bin Tang
Mechanical shock is a common problem that is present in many situations, such as ground motion, blast, explosions, crash, and impact. The development of passive, active, or adaptive control and isolation strategies for shock-induced vibration has experienced recent interest, typically due to the increasing demand in improved isolation requirements for sensitive equipment subjected to harsh environments. This paper presents a review of some of the significant recent works developed in the field, focusing on novel developments that contribute to the shock isolation. The article explores several isolation approaches considering passive, active, and nonlinear systems discussing both theoretical and experimental results. In addition, important outcomes of the work are reviewed. The paper concludes with suggestions for potential developments, applications, and recommendations for future research.

20 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
FAFabricio Almeida
Fabricio Almeida
MBMichael Brennan
Michael Brennan
PJPhillip Joseph
Phillip Joseph
SWStuart Whitfield
Stuart Whitfield
SDSimon Dray
Simon Dray
APAmarildo Tabone Paschoalini
Amarildo Tabone Paschoalini
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.

1 August 2015 in Journal of Vibration and Acoustics
Verified
Journal Article
Closed access
PDF file
AAAli Abolfathi
Ali Abolfathi
MBMichael Brennan
Michael Brennan
TWTimothy Waters
Timothy Waters
BTBin Tang
Bin Tang
Nonlinear isolators with high-static-low-dynamic-stiffness have received considerable attention in the recent literature due to their performance benefits compared to linear vibration isolators. A quasi-zero-stiffness (QZS) isolator is a particular case of this type of isolator, which has a zero dynamic stiffness at the static equilibrium position. These types of isolators can be used to achieve very low frequency vibration isolation, but a drawback is that they have purely hardening stiffness behavior. If something occurs to destroy the symmetry of the system, for example, by an additional static load being applied to the isolator during operation, or by the incorrect mass being suspended on the isolator, then the isolator behavior will change dramatically. The question is whether this will be detrimental to the performance of the isolator and this is addressed in this paper. The analysis in this paper shows that although the asymmetry will degrade the performance of the isolator compared to the perfectly tuned case, it will still perform better than the corresponding linear isolator provided that the amplitude of excitation is not too large.

11 September 2014 in Journal of Vibration and Acoustics
Verified
Journal Article
Closed access
PDF file
ZLZeqi Lu
Zeqi Lu
TYTiejun Yang
Tiejun Yang
MBMichael Brennan
Michael Brennan
XLXinhui Li
Xinhui Li
ZLZhigang Liu
Zhigang Liu
Linear single-stage vibration isolation systems have a limitation on their performance, which can be overcome passively by using linear two-stage isolations systems. It has been demonstrated by several researchers that linear single-stage isolation systems can be improved upon by using nonlinear stiffness elements, especially for low-frequency vibrations. In this paper, an investigation is conducted into whether the same improvements can be made to a linear two-stage isolation system using the same methodology for both force and base excitation. The benefits of incorporating geometric stiffness nonlinearity in both upper and lower stages are studied. It is found that there are beneficial effects of using nonlinearity in the stiffness in both stages for both types of excitation. Further, it is found that this nonlinearity causes the transmissibility at the lower resonance frequency to bend to the right, but the transmissibility at the higher resonance frequency is not affected in the same way. Generally, it is found that a nonlinear two-stage system has superior isolation performance compared to that of a linear two-stage isolator.