Jahangir Hossain

Dr. Jahangir Hossain

University of Technology Sydney
+1
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
Md. Alamgir HossainMd. Alamgir Hossain
Md. Alamgir Hossain
HPH. R. Pota
H. R. Pota
Jahangir HossainJahangir Hossain
Jahangir Hossain
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg

30 August 2017 in Energies
Verified
Journal Article
Open access
PDF file
Md. Alamgir HossainMd. Alamgir Hossain
Md. Alamgir Hossain
HPH. R. Pota
H. R. Pota
Walid IssaWalid Issa
Walid Issa
Jahangir HossainJahangir Hossain
Jahangir Hossain
Distributed generation (DG) is one of the key components of the emerging microgrid concept that enables renewable energy integration in a distribution network. In DG unit operation, inverters play a vital role in interfacing energy sources with the grid utility. An effective interfacing can successfully be accomplished by operating inverters with effective control techniques. This paper reviews and categorises different control methods (voltage and primary) for improving microgrid power quality, stability and power sharing approaches. In addition, the specific characteristics of microgrids are summarised to distinguish from distribution network control. Moreover, various control approaches including inner-loop controls and primary controls are compared according to their relative advantages and disadvantages. Finally, future research trends for microgrid control are discussed pointing out the research opportunities. This review paper will be a good basis for researchers working in microgrids and for industry to implement the ongoing research improvement in real systems.

1 February 2018 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
Khizir MahmudKhizir Mahmud
Khizir Mahmud
GTGr Town
Gr Town
SMSayidul Morsalin
Sayidul Morsalin
Jahangir HossainJahangir Hossain
Jahangir Hossain

22 October 2013 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Md Apel MahmudMd Apel Mahmud
Md Apel Mahmud
HPH. R. Pota
H. R. Pota
MAM. Aldeen
M. Aldeen
Jahangir HossainJahangir Hossain
Jahangir Hossain
In this paper a new nonlinear excitation controller design to enhance transient stability of multimachine power systems is presented. Partial feedback linearization is first used to transform the nonlinear power system model into a partially linear system comprising a reduced-order linear part and a nonlinear dynamic autonomous part. Then a linear state feedback stabilizing controller is designed for the reduced-order linear part using optimal control theory to enhance the stability of the whole system. In this way, the performance of the stabilizing controller would be independent of the operating points of the power system and therefore is superior to those designed for completely linearized systems. It is shown that the controller design method ensures the stability of the nonlinear dynamic autonomous part. The design method is applicable to multimachine power systems but tested on a 3-machine 11-bus two-area test system. The performance of the proposed control scheme to large disturbances is evaluated, through computer simulation, and compared with a conventional power system stabilizer and an exact feedback linearizing controller.

16 May 2018 in IEEE Access
Verified
Journal Article
Open access
Khizir MahmudKhizir Mahmud
Khizir Mahmud
Jahangir HossainJahangir Hossain
Jahangir Hossain
GTGr Town
Gr Town
Peak-load management is an important process that allows energy providers to reshape load profiles, increase energy efficiency, and reduce overall operational costs and carbon emissions. This paper presents an improved decision-tree-based algorithm to reduce the peak load in residential distribution networks by coordinated control of electric vehicles (EVs), photovoltaic (PV) units, and battery energy-storage systems (BESSs). The peak-load reduction is achieved by reading the domestic load in real time through a smart meter and taking appropriate coordinated action by a controller using the proposed algorithm. The proposed control algorithm was tested on a real distribution network using real load patterns and load dynamics, and validated in a laboratory experiment. Two types of EVs with fast and flexible charging capability, a PV unit, and BESSs were used to test the performance of the proposed control algorithm, which is compared with that of an artificial-neural-network technique. The results show that using the proposed method, the peak demand on the distribution grid can be reduced significantly, thereby greatly improving the load factor.

26 September 2011 in IEEE Systems Journal
Verified
Journal Article
Closed access
Jahangir HossainJahangir Hossain
Jahangir Hossain
HPH. R. Pota
H. R. Pota
Md Apel MahmudMd Apel Mahmud
Md Apel Mahmud
RRRodrigo A. Ramos
Rodrigo A. Ramos
The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.