Microelectromechanical systems sensors have been intensively developed utilizing various physical concepts, such as piezoresistive, piezoelectric, and thermoresistive effects. Among these sensing concepts, the thermoresistive effect is of interest for a wide range of thermal sensors and devices, thanks to its simplicity in implementation and high sensitivity. The effect of temperature on the electrical resistance of some metals and semiconductors has been thoroughly investigated, leading to the significant growth and successful demonstration of thermal-based sensors, such as temperature sensors, convective accelerometers and gyroscopes, and thermal flow sensors. In this paper, we review the fundamentals of the thermoresistive effect in metals and semiconductors. We also discuss the influence of design and fabrication parameters on the thermoresistive sensitivity. This paper includes several desirable features of thermoresistive sensors and recent developments in these sensors are summarized. This review provides insights into how it is affected by various parameters, and useful guidance for industrial designers in terms of high sensitivity and linearity and fast response.
1 April 2012 in International Journal of Hydrogen Energy
This paper reports on the thermoresistive properties of graphite on paper (GOP). A negative temperature coefficient of resistance (TCR) from −2900 to −4400 ppm K−1 was observed for the GOP. This negative and large TCR is attributed to an increase in the thermionic emission current over a low potential barrier with increasing temperature. The potential barrier was found to be 33 meV between the graphite grains. The paper also demonstrates the use of the GOP in a highly sensitive (0.83 mV (m s−1)−0.8 mW−1) GOP-based anemometer, indicating strong feasibility of using this material for low-cost and sensitive thermal sensing applications.
1 December 2005 in International Journal of Heat and Mass Transfer
In this paper, we report on a low-cost, environment-friendly and wearable thermal flow sensor, which can be manufactured in-house using pencil graphite as a sensing hot film and biodegradable printing paper as a substrate, without using any toxic solvents or cleanroom facilities. The hot film flow sensor offers excellent performance such as high signal-to-noise ratio ( 40 for an air flow velocity of 1 m s −1 ), high sensitivity to airflow (53.7 mV(m s −1 ) −0.8 ) and outstanding long-term stability (almost no drift in 24 h). The sensor can be comfortably affixed to the philtrum of patients and measures human respiration in realtime. The results indicate that the wearable thermal flow sensors fabricated by this solvent-free and user-friendly method could be employed in human respiratory monitoring.