Santiago Silvestre

Prof. Santiago Silvestre

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009 in Applied Energy
Verified
Journal Article
Closed access
SSSantiago Silvestre
Santiago Silvestre
ABA. Boronat
A. Boronat
ACA. Chouder
A. Chouder

1 October 2010 in Energy Conversion and Management
Verified
Journal Article
Closed access
ACA. Chouder
A. Chouder
SSSantiago Silvestre
Santiago Silvestre

1 July 2015 in Applied Soft Computing
Verified
Journal Article
Closed access
ABAbou Soufyane Benyoucef
Abou Soufyane Benyoucef
ACAissa Chouder
Aissa Chouder
KKKamel Kara
Kamel Kara
SSSantiago Silvestre
Santiago Silvestre
OSOussama Ait Sahed
Oussama Ait Sahed

16 September 2002
Verified
Book
Open access
LCLuis Castañer
Luis Castañer
SSSantiago Silvestre
Santiago Silvestre
Click on the title to browse this book

1 July 2017 in Solar Energy
Verified
Journal Article
Open access
EGElyes Garoudja
Elyes Garoudja
FHFouzi Harrou
Fouzi Harrou
YSYing Sun
Ying Sun
KKKamel Kara
Kamel Kara
ACAissa Chouder
Aissa Chouder
SSSantiago Silvestre
Santiago Silvestre
Faults in photovoltaic (PV) systems, which can result in energy loss, system shutdown or even serious safety breaches, are often difficult to avoid. Fault detection in such systems is imperative to improve their reliability, productivity, safety and efficiency. Here, an innovative model-based fault-detection approach for early detection of shading of PV modules and faults on the direct current (DC) side of PV systems is proposed. This approach combines the flexibility, and simplicity of a one-diode model with the extended capacity of an exponentially weighted moving average (EWMA) control chart to detect incipient changes in a PV system. The one-diode model, which is easily calibrated due to its limited calibration parameters, is used to predict the healthy PV array’s maximum power coordinates of current, voltage and power using measured temperatures and irradiances. Residuals, which capture the difference between the measurements and the predictions of the one-diode model, are generated and used as fault indicators. Then, the EWMA monitoring chart is applied on the uncorrelated residuals obtained from the one-diode model to detect and identify the type of fault. Actual data from the grid-connected PV system installed at the Renewable Energy Development Center, Algeria, are used to assess the performance of the proposed approach. Results show that the proposed approach successfully monitors the DC side of PV systems and detects temporary shading.Peer ReviewedPostprint (author's final draft

1 January 2012 in Simulation Modelling Practice and Theory
Verified
Journal Article
Closed access
ACAissa Chouder
Aissa Chouder
SSSantiago Silvestre
Santiago Silvestre
NSNawel Sadaoui
Nawel Sadaoui
LRLazhar Rahmani
Lazhar Rahmani