Rubén Abbas

Dr. Rubén Abbas

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in Energy Conversion and Management
Verified
Journal Article
Closed access
RARubén Abbas
Rubén Abbas
María José MontesMaría José Montes
María José Montes
MPM. Piera
M. Piera
JMJ.M. Martínez-Val
J.M. Martínez-Val

1 August 2013 in Energy Conversion and Management
Verified
Journal Article
Closed access
RARubén Abbas
Rubén Abbas
JAVIER MUÑOZ ANTONJAVIER MUÑOZ ANTON
JAVIER MUÑOZ ANTON
MVM. Valdés
M. Valdés
JMJ.M. Martínez-Val
J.M. Martínez-Val

1 January 2016 in Applied Energy
Verified
Journal Article
Closed access
ARAntonio Rovira
Antonio Rovira
RBRubén Barbero
Rubén Barbero
María José MontesMaría José Montes
María José Montes
RARubén Abbas
Rubén Abbas
FVFernando Varela
Fernando Varela

1 August 2014 in Energy
Verified
Journal Article
Open access
María José MontesMaría José Montes
María José Montes
CRCarlo Rubbia
Carlo Rubbia
RARubén Abbas
Rubén Abbas
JMJosé M. Martínez-Val
José M. Martínez-Val
Linear Fresnel collector arrays present some relevant advantages in the domain of concentrating solar power because of their simplicity, robustness and low capital cost. However, they also present important drawbacks and limitations, notably their average concentration ratio, which seems to limit significantly the performance of these systems.\ud \ud First, the paper addresses the problem of characterizing the mirror field configuration assuming hourly data of a typical year, in reference to a configuration similar to that of Fresdemo. For a proper comparative study, it is necessary to define a comparison criterion. In that sense, a new variable is defined, the useful energy efficiency, which only accounts for the radiation that impinges on the receiver with intensities above a reference value. As a second step, a comparative study between central linear Fresnel reflectors and compact linear Fresnel reflectors is carried out. This analysis shows that compact linear Fresnel reflectors minimize blocking and shading losses compared to a central configuration. However this minimization is not enough to overcome other negative effects of the compact Fresnel collectors, as the greater dispersion of the rays reaching the receiver, caused by the fact that mirrors must be located farther from the receiver, which yields to lower efficiencies

1 April 2012 in Applied Energy
Verified
Journal Article
Closed access
RARubén Abbas
Rubén Abbas
JAVIER MUÑOZ ANTONJAVIER MUÑOZ ANTON
JAVIER MUÑOZ ANTON
JMJ.M. Martínez-Val
J.M. Martínez-Val

1 March 2015 in Renewable Energy
Verified
Journal Article
Closed access
RARubén Abbas
Rubén Abbas
JMJ.M. Martínez-Val
J.M. Martínez-Val